Integrated optimization of the building envelope and the HVAC system in office building retrofitting

被引:0
|
作者
Cui, Wenjing [1 ]
Liu, Guiwen [2 ]
Wang, Yanyan [1 ]
Li, Kaijian [2 ]
机构
[1] School of Management Engineering, Shandong Jianzhu University, Jinan,250101, China
[2] School of Management Science and Real Estate, Chongqing University, Chongqing,400044, China
基金
中国国家社会科学基金;
关键词
Air curtains - Air preheaters - Concretes - HVAC - Linear programming - Mortar - Multiobjective optimization - Thermal comfort - Thermal insulation - Walls (structural partitions);
D O I
10.1016/j.csite.2024.105185
中图分类号
学科分类号
摘要
Increasing the energy efficiency of existing buildings is the major strategy to reach carbon neutral targets, given that the building sector is a major emitter. In particular, one major part of building energy usage is the building heating, ventilation and air-cooling system, which are highly depending on the thermal performance of building envelope and increase the challenge of selecting optimal packages of energy efficiency measures. This paper thereby presents a method for optimizing the building envelope and heating, ventilation and air-cooling system. The simulation-based NSGA-III approach developed in this paper is based on coupling the dynamic simulation models created in EnergyPlus software with the non-dominated sorting genetic algorithm, as the engine that performs an optimization process. A large domain of energy efficiency packages combined with heating, ventilation and air-cooling systems and building envelope are investigated to minimize energy consumption, retrofit cost and thermal discomfort in indoor environments, which including ideal loads air system, four pipe fan coil system and variable refrigerant flow system, insulation materials and insulation thickness for external walls and roof, different types of external windows, and window-wall ratio. An office building in Chongqing was chosen as a case study to demonstrate the practical implementation of the proposed method. The results show that the four pipe fan coil system was superior in the diversity and performance of the Pareto front. Then, the optimal packages were generated by a synthetic method, which have 58.57 kWh/m2 of energy consumption, 30.76 CNY/m2 of retrofit cost and 40.67 % of the percentage of thermal discomfort hours. The results also indicate that the yearly energy savings rates are 17.30 %, 23.05 % and 21.10 % separately for ideal loads air system, four pipe fan coil system and variable refrigerant flow system after performing optimization. These results highlight the importance and necessity of performing an optimization procedure for existing buildings to select the optimal retrofit measures. © 2024 The Authors
引用
下载
收藏
相关论文
共 50 条
  • [31] Optimization of operation times of a heating system in office building
    Yang, Inho
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2020, 19 (04) : 400 - 415
  • [32] Building Integrated Photovoltaic Systems as a Sustainable Option for Retrofitting of Office Buildings in South East Europe
    Serasidou, Anna
    Martinopoulos, Georgios
    IMPROVING ENERGY EFFICIENCY IN COMMERCIAL BUILDINGS AND SMART COMMUNITIES, 2020, : 103 - 121
  • [33] Evaluation of thermal comfort in a historic building refurbished to an office building with modernized HVAC systems
    Bakhtiari, H.
    Akander, J.
    Cehlin, M.
    ADVANCES IN BUILDING ENERGY RESEARCH, 2020, 14 (02) : 218 - 237
  • [34] Urban building energy modeling considering the heterogeneity of HVAC system stock: A case study on Japanese office building stock
    Kim, Bumjoon
    Yamaguchi, Yohei
    Kimura, Shun
    Ko, Yumei
    Ikeda, Kosuke
    Shimoda, Yoshiyuki
    ENERGY AND BUILDINGS, 2020, 207
  • [35] Urban building energy modeling considering the heterogeneity of HVAC system stock: A case study on Japanese office building stock
    Kim, Bumjoon
    Yamaguchi, Yohei
    Kimura, Shun
    Ko, Yumei
    Ikeda, Kosuke
    Shimoda, Yoshiyuki
    ENERGY AND BUILDINGS, 2019, 199 : 547 - 561
  • [36] Optimization for the Model Predictive Control of Building HVAC System and Experimental Verification
    Si, Qiang
    Wei, Jianjun
    Li, Yuan
    Cai, Hao
    BUILDINGS, 2022, 12 (10)
  • [37] Review on HVAC System Optimization Towards Energy Saving Building Operation
    Selamat, Hazlina
    Haniff, Mohamad Fadzli
    Sharif, Zainon Mat
    Attaran, Seyed Mohammad
    Sakri, Fadhilah Mohd
    Razak, Muhammad Al'Hapis Bin Abdul
    INTERNATIONAL ENERGY JOURNAL, 2020, 20 (03): : 345 - 357
  • [38] Application of a Run-Around Membrane Energy Exchanger in an Office Building HVAC System
    Rasouli, Mohammad
    Akbari, Soheil
    Hemingson, Howard
    Besant, Robert W.
    Simonson, Carey J.
    ASHRAE TRANSACTIONS 2011, VOL 117, PT 2, 2011, 117 : 686 - 703
  • [39] Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system
    Bonetta, Sa.
    Bonetta, Si.
    Mosso, S.
    Sampo, S.
    Carraro, E.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 161 (1-4) : 473 - 483
  • [40] Decision Making for HVAC&R System Selection for a Typical Office Building in the UK
    Shahrestani, Mehdi
    Yao, Runming
    Cook, Geoffrey K.
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 222 - 229