Algorithm for the breakage of ice-covered quad bundle conductors based on CR method

被引:0
|
作者
Lu, Jiabo [1 ,2 ]
Liu, Xiaohui [1 ]
Lu, Zhongbing [3 ]
Huang, Zhan [1 ]
Fan, Li [1 ]
Wu, Haitao [4 ]
Chen, Siwei [5 ]
机构
[1] School of Civil Engineering, Chongqing Jiaotong University, Chongqing,400074, China
[2] State Key Laboratory of Bridge and Tunnel Engineering in Mountain Areas, Chongqing Jiaotong University, Chongqing,400074, China
[3] Henan Electric Power Research Institute, Zhengzhou,450052, China
[4] Chongqing Electric Power Research Institute, Chongqing,404100, China
[5] State Grid Chengdu Electric Power Company, Chengdu,610021, China
来源
Zhendong yu Chongji/Journal of Vibration and Shock | 2024年 / 43卷 / 22期
关键词
C++ (programming language);
D O I
10.13465/j.cnki.jvs.2024.22.035
中图分类号
学科分类号
摘要
In order to analyze the disconnection conditions of ice-covered split wires more quickly and accurately, a finite element model of beam and rod elements was developed based on the co-rotational (CR) method. A finite element implementation method for the disconnection of node failure was proposed, and the reliability of the method was verified by comparison with experiment results. The finite element program was written in C + + language, and the program was visualized through QT and VTK toolkits. Finally, a three-level ice-coated four-split finite element model was established. Based on this finite element model, the effects of different ice coating thicknesses and different disconnection positions on the tension of the sub-conductors and the bending moment of the spacer rods were studied. The results show that the spacer rods bear additional torque when the sub-conductor breaks, and the maximum tension value of the unbroken conductor occurs near the spacer rod, and the tension decreases successively to the normal operating level along the conductor away from the break point. In the case of ice coating, the maximum tension of single sub-conductor and twin sub-conductors increases linearly with the ice coating thickness. When three sub-conductors break, all sub-conductors will break, and when all four sub-conductors break, it can be simplified to a single sub-conductor in the calculation. The simulation results provide a reference for transmission line design and fault analysis. The proposed wire breakage simulation method provides a reliable finite element implementation method for the simulation of wire breakage. © 2024 Chinese Vibration Engineering Society. All rights reserved.
引用
收藏
页码:318 / 325
相关论文
共 50 条
  • [21] Modeling of DC flashover on ice-covered HV insulators based on dynamic electric field analysis
    Yang, Qing
    Sima, Wenxia
    Sun, Caixin
    Shu, Lichun
    Hu, Qin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) : 1418 - 1426
  • [22] Application of the finite element method to model wind-induced vibration of single and quad-bundle conductors
    Kaunda, M. A. E.
    Khoza, S. N.
    SACAM 2006: FIFTH SOUTH AFRICAN CONFERENCE ON COMPUTATIONAL AND APPLIED MECHANICS, PTS 1-3, 2006, : 110 - +
  • [23] A new AC flashover model of ice-covered HV insulators based on numerical electric field analysis
    Yang, Q.
    Sima, W.
    Wu, K.
    Li, J.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2008, 2 (04) : 600 - 609
  • [24] Potential and electric-field calculation along an ice-covered composite insulator with finite-element method
    Sima, W.
    Yang, Q.
    Sun, C.
    Guo, F.
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2006, 153 (03) : 343 - 349
  • [25] Online Ice-melting Method Based on Flexible Regulation of Zero-sequence Reactive Current for Ice-covered Lines in Distribution Networks Without Power Outages
    Zhang B.
    Zheng Z.
    Guo M.
    Dianwang Jishu/Power System Technology, 2024, 48 (02): : 913 - 922
  • [26] DC Flashover Performance of Ice-Covered Insulator Strings Adopted in ±800kV Transmission Lines Based on Up-And-Down Method
    Yu, Xinzhe
    Zhou, Jun
    Liu, Bo
    Su, Zhiyi
    Huang, Ruiping
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 775 - 778
  • [27] Path planning for ships assisted by the icebreaker in ice-covered waters in the Northern Sea Route based on optimal control
    Shu, Yaqing
    Zhu, Yujie
    Xu, Feng
    Gan, Langxiong
    Lee, Paul Tae-Woo
    Yin, Jianchuan
    Chen, Jihong
    OCEAN ENGINEERING, 2023, 267
  • [28] A Dual-Threshold Algorithm for Ice-Covered Lake Water Level Retrieval Using Sentinel-3 SAR Altimetry Waveforms
    Tang, Fucai
    Chen, Peng
    An, Zhiyuan
    Xiong, Mingzhu
    Chen, Hao
    Qiu, Liangcai
    SENSORS, 2023, 23 (24)
  • [29] Marine Mammal-Based Observations of Subsurface-Intensified Eddies in the Seasonally Sea Ice-Covered Southern Ocean
    Kosty, Jennifer A.
    Zhao, Ken X.
    Stewart, Andrew L.
    McCoy, Daniel E.
    Bianchi, Daniele
    Manucharyan, Georgy E.
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 2025, 130 (04)
  • [30] Estimation of surface heat flux based on rawinsonde observation in the southwestern part of the Sea of Okhotsk under ice-covered condition
    Iwamoto, K
    Domon, K
    Honda, M
    Tachibana, Y
    Takeuchi, K
    JOURNAL OF THE METEOROLOGICAL SOCIETY OF JAPAN, 2001, 79 (02) : 687 - 694