The corrosion resistance, biocompatibility and antibacterial properties of the silver-doped dicalcium phosphate dihydrate coating on the surface of the additively manufactured NiTi alloy

被引:0
|
作者
Liang, Ping [1 ]
Li, Panpan [1 ,2 ]
Yang, Yanan [1 ,2 ]
Yang, Kongyuan [3 ]
Mao, Chunling [4 ]
Chi, Haojie [1 ,2 ]
Zhang, Jian [1 ,2 ]
Yu, Zhenglei [1 ,2 ]
Xu, Zezhou [1 ,2 ]
Guo, Yunting [1 ,2 ,5 ]
Ren, Luquan [1 ,2 ]
机构
[1] Jilin Univ, Key Lab Bion Engn, Minist Educ, Changchun 130022, Peoples R China
[2] Jilin Univ, Weihai Inst Bion, Weihai 264402, Peoples R China
[3] Univ Sci & Technol, Sch Mech & Elect Engn, Changchun 130022, Peoples R China
[4] Changchun Vocat Inst Technol, Changchun 130000, Peoples R China
[5] Northeast Forestry Univ, Coll Mech & Elect Engn, Harbin 150042, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划; 中国博士后科学基金;
关键词
Additive manufacturing; NiTi alloy; Corrosion resistance; Biomineralization; Antibacterial activity; MAGNESIUM ALLOY; HYDROXYAPATITE; CYTOCOMPATIBILITY; STABILITY; COMPOSITE; BEHAVIOR; STEEL; ZINC; AG;
D O I
10.1016/j.ceramint.2024.08.250
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Additive manufacturing (AM) of NiTi alloys has attracted significant attention for its exceptional forming precision and suitability for processing complex medical implant structures. However, challenges such as the excessive release of Ni2+, bioinertness, and insufficient antibacterial ability have emerged as primary factors impeding the application of NiTi alloy in the medical field. To address these issues, the silver-doped dicalcium phosphate dihydrate (Ag-DCPD) coating is electrochemically deposited on the LPBF-NiTi alloy surface for the first time. The study investigates the effects of varying Ag doping content (2 %, 4 %, and 6 %) on morphology, corrosion resistance, biomineralization, and long-term stability of DCPD coating using scanning electron microscopy (SEM), electrochemical analysis, and immersion tests. Results show that the 4Ag-DCPD coating exhibits the most uniform and dense surface morphology, excellent corrosion resistance, and biomineralization. The corrosion current density (I-corr) is two orders of magnitude lower than that of the LPBF-NiTi alloy matrix (from 1.1 x 10(-6) to 1.4 x 10(-8)), and a dense hydroxyapatite (HA) layer forms after immersion testing. In vitro cell experiments indicate that the 4Ag-DCPD coating maintains high cell viability, favorable cell morphology, and excellent biocompatibility. Additionally, the 4Ag-DCPD coating demonstrates effective antibacterial activity against Escherichia coli (79.75 %) and Staphylococcus aureus (69.33 %), which reduces the risk of implantation infection. Overall, the 4Ag-DCPD coated LPBF-NiTi alloy shows promising clinical application potential as a medical implant.
引用
收藏
页码:43994 / 44007
页数:14
相关论文
共 50 条
  • [21] A continuous method to prepare poorly crystalline silver-doped calcium phosphate ceramics with antibacterial properties
    Range, S.
    Hagmeyer, D.
    Rotan, O.
    Sokolova, V.
    Verheyen, J.
    Siebers, B.
    Epple, M.
    RSC ADVANCES, 2015, 5 (54): : 43172 - 43177
  • [22] Enhancement of electrical conductivity and corrosion resistance by silver shell-copper core coating of additively manufactured AlSi10Mg alloy
    Rautio, Timo
    Hamada, Atef
    Kumpula, Jani
    Jarvenpaa, Antti
    Allam, Tarek
    SURFACE & COATINGS TECHNOLOGY, 2020, 403
  • [23] Enhanced corrosion resistance and biocompatibility of biodegradable magnesium alloy modified by calcium phosphate/collagen coating
    Guo, Yunting
    Su, Yingchao
    Gu, Rui
    Zhang, Zhihui
    Li, Guangyu
    Lian, Jianshe
    Ren, Luquan
    SURFACE & COATINGS TECHNOLOGY, 2020, 401 (401):
  • [24] Additively manufactured porous Ti6Al4V Alloy with excellent mechanical properties, corrosion resistance, in vitro and in vivo biocompatibility
    Zhang, Lei
    Hu, Hongyan
    Wang, Quan
    Zhou, Jing
    Liu, Yan
    Li, Zonghao
    Zhang, Yonghui
    Kui, Zhitong
    He, Zhengyuan
    Jiang, Yehua
    JOURNAL OF ALLOYS AND COMPOUNDS, 2024, 1009
  • [25] Corrosion resistance and surface biocompatibility of a microarc oxidation coating on a Mg-Ca alloy
    Gu, X. N.
    Li, N.
    Zhou, W. R.
    Zheng, Y. F.
    Zhao, X.
    Cai, Q. Z.
    Ruan, Liquan
    ACTA BIOMATERIALIA, 2011, 7 (04) : 1880 - 1889
  • [26] Surface Modification of NiTi Alloy with Sputtered Tantalum Coatings to Improve its Hardness, Corrosion Resistance and Biocompatibility
    Khathim, Sena'a E.
    Al-Rawi, Bilal K.
    Khalaf, Mohammed K.
    INTERNATIONAL JOURNAL OF NANOSCIENCE, 2024, 23 (03)
  • [27] The surface alloying effect of silicon in a binary NiTi-base alloy on the corrosion resistance and biocompatibility of the material
    Psakhie, S. G.
    Lotkov, A. I.
    Meisner, L. L.
    Meisner, S. N.
    Matveeva, V. A.
    RUSSIAN PHYSICS JOURNAL, 2013, 55 (09) : 1063 - 1073
  • [28] The surface alloying effect of silicon in a binary NiTi-base alloy on the corrosion resistance and biocompatibility of the material
    S. G. Psakhie
    A. I. Lotkov
    L. L. Meisner
    S. N. Meisner
    V. A. Matveeva
    Russian Physics Journal, 2013, 55 : 1063 - 1073
  • [29] Corrosion behavior of SiC-hyaluronic acid-Sr doped dicalcium phosphate dihydrate composite coating in simulated body fluid
    Zhang Leilei
    Li Hejun
    Zhao Yizhi
    Li Bingxin
    Ren Fangyuan
    Chang Mochen
    Zhang Yulei
    CERAMICS INTERNATIONAL, 2017, 43 (02) : 2842 - 2846
  • [30] Strategically designed bioactive dual-layer coating of octacalcium phosphate and dicalcium phosphate dihydrate for enhancement of the corrosion resistance of pure magnesium for orthopaedic applications
    Hashemi, Tina Sadat
    Jaiswal, Satish
    Celikin, Mert
    Mccarthy, Helen O.
    Levingstone, Tanya J.
    Dunne, Nicholas J.
    SURFACE & COATINGS TECHNOLOGY, 2025, 495