Research on hydration heat effect and influence parameters of concrete filled steel shell composite pylon

被引:0
|
作者
Zhang, Ziao [1 ]
Liu, Jiang [1 ]
Liu, Yongjian [1 ,2 ]
Lyu, Yi [1 ]
Gong, Boxu [1 ]
Ma, Yinping [2 ]
机构
[1] Changan Univ, Sch Highway, Xian 710064, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Bridge engineering; Concrete filled steel shell composite pylon; Hydration reaction; Temperature field; Cracking risk;
D O I
10.1016/j.istruc.2024.107860
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the large volume and significant hydration heat of concrete filled steel shell composite (CFSSC) pylons, concrete cracking during the hydration heat process can hinder the normal operation of the CFSSC pylons. To investigate the temperature field, thermal effect and influencing parameters of hydration action in CFSSC pylons, a research is conducted based on the Longgun River Bridge's CFSSC pylon. Upon verifying the consistency between simulation and measured results, a comparative analysis is conducted on the temperature field and thermal effect of the CFSSC pylon and concrete pylon. The effects of five parameters, including the final cement heat release, peak time of hydration rate, initial temperature, ambient temperature, and insulation layer thickness, are analyzed. The results indicate that the maximum temperature of the CFSSC pylon reaches 73.47 degrees C, with a maximum temperature difference of 40.75 degrees C. The maximum strain of concrete is 160 mu epsilon, the area and the depth of the cracking risk reachs 20 m2 and 24.5 cm. The surface temperature of the CFSSC pylon is 3.9 degrees C higher than that of the concrete pylon, and the tensile stress on the top surface of the CFSSC pylon's concrete is 1.09 MPa higher and 1.24 MPa lower on the sides compared to the concrete pylon. Applying lateral constraints to the top surface of the CFSSC pylon could reduce the cracking risk significantly. Adjusting each parameter reduces the concrete temperature difference by up to 20 % to 45 %. After proposing an optimization schemes, the maximum temperature is reduced by 14.25 degrees C and the maximum temperature difference is reduced by 29.58 degrees C. The cracking area is less than 0.5 m2, and the crack depth is less than 5.5 cm. Based on the preceding analysis, this paper could offer invaluable guidance for the design and construction of CFSSC pylons.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Research on Mechanical Property and Economic Effect of Contractible Concrete Filled Steel Tube Support
    Li, Hui
    Jiang, Bei
    Yang, Bin
    Wang, Qi
    Wang, Hongtao
    Li, Zhi
    Li, Weiteng
    ADVANCES IN CIVIL ENGINEERING, PTS 1-4, 2011, 90-93 : 722 - +
  • [42] Research on Performance Effect Factors of flexural member for concrete filled rectangular steel tube
    Song Jiqiang
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 1130 - 1134
  • [43] Mechanical Behavior and Structural Optimization of Steel-Concrete Composite Cable-Pylon Anchor
    Xiao L.
    Liu L.
    Wei X.
    Liu D.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2019, 54 (05): : 923 - 930and944
  • [44] Effect of axial compression ratio on concrete-filled steel tube composite shear wall
    Hou, Hetao
    Fu, Weiqi
    Qiu, Canxing
    Cheng, Jirun
    Qu, Zhe
    Zhu, Wencan
    Ma, Tianxiang
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (03) : 656 - 669
  • [45] Improved Composite Effect of Square Concrete-Filled Steel Tubes with Diagonal Binding Ribs
    Zhou, Zheng
    Gan, Dan
    Zhou, Xuhong
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (10)
  • [46] Experimental research on aseismic behavior of high ductile concrete filled steel plate composite coupling beams
    Deng M.-K.
    Lü H.
    Song H.-Z.
    Gongcheng Lixue/Engineering Mechanics, 2019, 36 (03): : 192 - 202
  • [47] EXPERIMENTAL RESEARCH ON COMPOSITE L-SHAPED CONCRETE-FILLED STEEL TUBE SHORT COLUMNS
    Du, Guofeng
    Xu, Shuzhen
    Xinsong
    Xu, Chengxiang
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 1090 - 1097
  • [48] Influence of substructure model on progressive collapse resistance of concrete-filled steel tube composite frame
    Zheng L.
    Wang W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 : 76 - 88
  • [49] Aseismic research of composite shear wall and core walls with rectangular concrete filled steel tube columns
    College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China
    不详
    不详
    Gongcheng Lixue, 2008, SUPPL. (58-70):
  • [50] Experimental research on seismic behavior of a two-story concrete filled steel tubular composite frame
    Zong, Zhouhong
    Lin, Dongxin
    Fang, Zhenzheng
    Qiu, Fawei
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2002, 23 (02):