Research on hydration heat effect and influence parameters of concrete filled steel shell composite pylon

被引:0
|
作者
Zhang, Ziao [1 ]
Liu, Jiang [1 ]
Liu, Yongjian [1 ,2 ]
Lyu, Yi [1 ]
Gong, Boxu [1 ]
Ma, Yinping [2 ]
机构
[1] Changan Univ, Sch Highway, Xian 710064, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Bridge engineering; Concrete filled steel shell composite pylon; Hydration reaction; Temperature field; Cracking risk;
D O I
10.1016/j.istruc.2024.107860
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the large volume and significant hydration heat of concrete filled steel shell composite (CFSSC) pylons, concrete cracking during the hydration heat process can hinder the normal operation of the CFSSC pylons. To investigate the temperature field, thermal effect and influencing parameters of hydration action in CFSSC pylons, a research is conducted based on the Longgun River Bridge's CFSSC pylon. Upon verifying the consistency between simulation and measured results, a comparative analysis is conducted on the temperature field and thermal effect of the CFSSC pylon and concrete pylon. The effects of five parameters, including the final cement heat release, peak time of hydration rate, initial temperature, ambient temperature, and insulation layer thickness, are analyzed. The results indicate that the maximum temperature of the CFSSC pylon reaches 73.47 degrees C, with a maximum temperature difference of 40.75 degrees C. The maximum strain of concrete is 160 mu epsilon, the area and the depth of the cracking risk reachs 20 m2 and 24.5 cm. The surface temperature of the CFSSC pylon is 3.9 degrees C higher than that of the concrete pylon, and the tensile stress on the top surface of the CFSSC pylon's concrete is 1.09 MPa higher and 1.24 MPa lower on the sides compared to the concrete pylon. Applying lateral constraints to the top surface of the CFSSC pylon could reduce the cracking risk significantly. Adjusting each parameter reduces the concrete temperature difference by up to 20 % to 45 %. After proposing an optimization schemes, the maximum temperature is reduced by 14.25 degrees C and the maximum temperature difference is reduced by 29.58 degrees C. The cracking area is less than 0.5 m2, and the crack depth is less than 5.5 cm. Based on the preceding analysis, this paper could offer invaluable guidance for the design and construction of CFSSC pylons.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Experimental research on confinement effect of axial compression composite concrete-filled square steel tubular short columns
    Li, Bin
    Gao, Chun-Yan
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2012, 44 (SUPPL.1): : 33 - 37
  • [22] Tensile stiffness of perfobond rib connectors in steel-concrete composite pylon of bridges
    Sun, Lipeng
    Liu, Yongjian
    Wang, Haitao
    Shi, Fengrong
    Liu, Jiang
    Jiang, Lei
    ENGINEERING STRUCTURES, 2023, 284
  • [23] Effect of Steel Fibers on Heat of Hydration and Mechanical Properties of Concrete Containing Fly Ash
    Mehmood, Sajid
    Butt, Faheem
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2019, 38 (01) : 83 - 94
  • [24] A review on research and applications of concrete-filled steel-plate composite bridge tower
    Jiansheng F.
    Yaoyu Z.
    Bing C.
    Leyong W.
    Liji H.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2023, 56 (04): : 61 - 71
  • [25] Experimental research on concrete filled steel plate composite coupling beams (I): Seismic behavior
    Nie, Jianguo
    Hu, Hongsong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2014, 35 (05): : 1 - 9
  • [26] Experimental research on the composite column with cone of concrete filled steel tube under axial loads
    Dept. of Civil Eng., South China Univ. of Technol., Guangzhou 510640, China
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2002, 32 (05): : 715 - 718
  • [27] EFFECT OF MATERIALS COMPONENT ON HYDRATION HEAT OF CONCRETE
    Wang, Peiming
    Pan, Wei
    Ma, Baoguo
    Wen, Xiaodong
    MICROSTRUCTURE RELATED DURABILITY OF CEMENTITIOUS COMPOSITES, VOLS 1 AND 2, 2008, 61 : 61 - +
  • [28] Influence Analysis of Parameters Variation on Dynamic Characteristic for Concrete Filled Steel Tubulur Arch Bridge
    Sun, Hao
    Li, Xiaogang
    Liu, Shilin
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 1429 - +
  • [29] Influence of heat of hydration on the mechanical properties and the durability of concrete
    Moriwake, A
    Fukute, T
    Suzuki, Y
    2001 SECOND INTERNATIONAL CONFERENCE ON ENGINEERING MATERIALS, VOL II, 2001, : 567 - 578
  • [30] Research on constitutive relationships of concrete filled steel tube
    Chen, X. M.
    Duan, J.
    Li, Y. G.
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON CIVIL, ARCHITECTURAL AND HYDRAULIC ENGINEERING (ICCAHE 2016), 2016, 95 : 470 - 476