Evaluation of a Three-Dimensional Printed Interventional Simulator for Cardiac Ablation Therapy Training

被引:0
|
作者
Saija, Carlo [1 ,2 ]
Sabu, Sachin [1 ,3 ]
Leung, Lisa [4 ]
Lowe, Ellie [1 ]
Al-Bahrani, Noor [1 ]
Pinto, Marco Antonio Coutinho [5 ]
Herridge, Mark [3 ]
Chowdhury, Nadia M. [1 ]
Gibson, Gregory [3 ]
Byrne, Calum [3 ]
Gabbeta, Adharvan [1 ]
Marion, Ewen [1 ]
Chavan, Rashi [1 ]
Behar, Jonathan [1 ,3 ]
Pontiki, Antonia Agapi [1 ]
Berthet-Rayne, Pierre [2 ]
Housden, Richard James [1 ]
Rhode, Kawal [1 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London WC2R 2LS, England
[2] Caranx Med, F-06200 Nice, France
[3] Guys & St Thomass NHS Fdn Trust, London SE1 7EH, England
[4] St George Hosp, London SW17 0QT, England
[5] Biosense Webster, Irvine, CA 92618 USA
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 18期
关键词
cardiac ablation; interventional training; medical simulator; 3D printing; cardiac phantom; fluoroscopy guidance; PERFORMANCE; PHANTOM;
D O I
10.3390/app14188423
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cardiac ablation (CA) is an interventional electrophysiological procedure used to disrupt arrhythmic substrates in the myocardium by inducing localized scarring. Current CA training relies on the master-apprentice model. In different fields of medicine including CA, virtual and physical simulators have proven to enhance, and even outperform, conventional training modalities while providing a risk-free learning environment. Despite the benefits, high costs and operational difficulties limit the widespread use of interventional simulators. Our previous research introduced a low-cost CA simulator using a 3D-printed biatrial cardiac model, successfully recording ten ablation lesions on the phantom myocardium. In this work, we present and evaluate an enhanced version: compared to the previous version, the cardiac phantom's electrical behavior and ablation settings were optimized to produce consistent lesions, while 3D-printed components improved the haptic and radiographic properties of the simulator. Seven cardiologists compared the experimental simulator's performance to the leading commercial system from Heartroid in a 24-question survey on a 5-point Likert scale. The four following areas of fidelity were considered: catheter entry, anatomical correctness, radiographic appearance, and mapping and ablation. The experimental simulator significantly outperformed the commercial system (p < 0.01), particularly in radiographic appearance (p < 0.01). The results show the potential for the experimental simulator in routine CA training.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Three-dimensional printed dry lab training models to simulate roboticassisted pancreaticojejunostomy
    Wei, Fangqiang
    Xu, Mingen
    Lai, Xuecong
    Zhang, Jiye
    Yiengpruksawan, Anusak
    Lu, Yi
    Liu, Junwei
    Wang, Zhifei
    ANZ JOURNAL OF SURGERY, 2019, 89 (12) : 1631 - 1635
  • [42] Three-dimensional printed model of impacted third molar for surgical extraction training
    Feng, Jing
    Qi, Wenting
    Duan, Shengfeng
    Bao, Chongyun
    Zhang, Xiaohui
    Cai, Bohong
    Liu, Xian
    JOURNAL OF DENTAL EDUCATION, 2021, 85 (12) : 1828 - 1836
  • [43] Preoperative skill evaluation in transabdominal preperitoneal (TAPP) inguinal hernia repair using a three-dimensional printed TAPP repair simulator
    Nishihara, Yuichi
    Isobe, Yoh
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (01): : 270 - 274
  • [44] Creation and validation of three-dimensional printed models for basic nasal endoscopic training
    Chen Zhuo
    Lyu Lei
    Zhao Yulin
    Liu Wentao
    Wu Shuangxia
    Wang Chao
    Zhang Yaqian
    Huang Shuman
    Dong Dong
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2019, 9 (06) : 695 - 701
  • [45] Novel device prototyping for endoscopic cell sheet transplantation using a three-dimensional printed simulator
    Osada, Hiroaki
    Ho, Wen-Jin
    Yamashita, Hideki
    Yamazaki, Kazuhiro
    Ikeda, Tadashi
    Minatoya, Kenji
    Masumoto, Hidetoshi
    REGENERATIVE THERAPY, 2020, 15 : 258 - 264
  • [46] Preoperative skill evaluation in transabdominal preperitoneal (TAPP) inguinal hernia repair using a three-dimensional printed TAPP repair simulator
    Yuichi Nishihara
    Yoh Isobe
    Surgical Endoscopy, 2021, 35 : 270 - 274
  • [47] Three-Dimensional Printed Cardiac Models Demonstrating Extensive Cardiac Calcification Assist in Preprocedural Planning
    Foley, Ross
    Walsh, Kevin
    O'Cearbhaill, Eoin
    Mcmahon, Colin J.
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2025,
  • [48] Is a Three-Dimensional Printed Cardiac Model Better Than a Traditional Cardiac Model for Medical Education?
    Huang, Chin-Chou
    ACTA CARDIOLOGICA SINICA, 2017, 33 (06) : 670 - 671
  • [49] Three-dimensional metrology for printed electronics
    Bromberg, Vadim
    Harding, Kevin
    DIMENSIONAL OPTICAL METROLOGY AND INSPECTION FOR PRACTICAL APPLICATIONS VI, 2017, 10220
  • [50] Three-Dimensional Printed Graphene Foams
    Sha, Junwei
    Li, Yilun
    Salvatierra, Rodrigo Villegas
    Wang, Tuo
    Dong, Pei
    Ji, Yongsung
    Lee, Seoung-Ki
    Zhang, Chenhao
    Zhang, Jibo
    Smith, Robert H.
    Ajayan, Pulickel M.
    Lou, Jun
    Zhao, Naiqin
    Tour, James M.
    ACS NANO, 2017, 11 (07) : 6860 - 6867