Evaluation of a Three-Dimensional Printed Interventional Simulator for Cardiac Ablation Therapy Training

被引:0
|
作者
Saija, Carlo [1 ,2 ]
Sabu, Sachin [1 ,3 ]
Leung, Lisa [4 ]
Lowe, Ellie [1 ]
Al-Bahrani, Noor [1 ]
Pinto, Marco Antonio Coutinho [5 ]
Herridge, Mark [3 ]
Chowdhury, Nadia M. [1 ]
Gibson, Gregory [3 ]
Byrne, Calum [3 ]
Gabbeta, Adharvan [1 ]
Marion, Ewen [1 ]
Chavan, Rashi [1 ]
Behar, Jonathan [1 ,3 ]
Pontiki, Antonia Agapi [1 ]
Berthet-Rayne, Pierre [2 ]
Housden, Richard James [1 ]
Rhode, Kawal [1 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London WC2R 2LS, England
[2] Caranx Med, F-06200 Nice, France
[3] Guys & St Thomass NHS Fdn Trust, London SE1 7EH, England
[4] St George Hosp, London SW17 0QT, England
[5] Biosense Webster, Irvine, CA 92618 USA
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 18期
关键词
cardiac ablation; interventional training; medical simulator; 3D printing; cardiac phantom; fluoroscopy guidance; PERFORMANCE; PHANTOM;
D O I
10.3390/app14188423
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cardiac ablation (CA) is an interventional electrophysiological procedure used to disrupt arrhythmic substrates in the myocardium by inducing localized scarring. Current CA training relies on the master-apprentice model. In different fields of medicine including CA, virtual and physical simulators have proven to enhance, and even outperform, conventional training modalities while providing a risk-free learning environment. Despite the benefits, high costs and operational difficulties limit the widespread use of interventional simulators. Our previous research introduced a low-cost CA simulator using a 3D-printed biatrial cardiac model, successfully recording ten ablation lesions on the phantom myocardium. In this work, we present and evaluate an enhanced version: compared to the previous version, the cardiac phantom's electrical behavior and ablation settings were optimized to produce consistent lesions, while 3D-printed components improved the haptic and radiographic properties of the simulator. Seven cardiologists compared the experimental simulator's performance to the leading commercial system from Heartroid in a 24-question survey on a 5-point Likert scale. The four following areas of fidelity were considered: catheter entry, anatomical correctness, radiographic appearance, and mapping and ablation. The experimental simulator significantly outperformed the commercial system (p < 0.01), particularly in radiographic appearance (p < 0.01). The results show the potential for the experimental simulator in routine CA training.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Cardiac toxicity Prediction of drug using Three-dimensional Heart Simulator
    Okada, Jun-ichi
    Yoshinaga, Takashi
    Kurokawa, Junko
    Washio, Takumi
    Furukawa, Tetsushi
    Sawada, Kohei
    Sugiura, Seiryo
    Hisada, Toshiaki
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2016, 130 (03) : S61 - S61
  • [22] Three-dimensional printed electronics
    Jennifer A. Lewis
    Bok Y. Ahn
    Nature, 2015, 518 : 42 - 43
  • [23] Three-dimensional printed electronics
    Lewis, Jennifer A.
    Ahn, Bok Y.
    NATURE, 2015, 518 (7537) : 42 - 43
  • [24] Three-Dimensional Printed Hysteria
    Hassan, Karriem
    3D PRINTING AND ADDITIVE MANUFACTURING, 2020, 7 (02) : 45 - 47
  • [25] Innovating Flexor Tendon Repair Training with a Three-dimensional Printed Model
    Boyajian, Michael K.
    Davidson, Amelia L.
    Molair, Will
    Woo, Albert S.
    Crozier, Joseph W.
    Johnson, James E.
    Bhatt, Reena
    Danelson, Kerry A.
    Argenta, Anne
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2024, 12 (09)
  • [27] Creation of a three-dimensional printed spine model for training in pain procedures
    Koh, Jae Chul
    Jang, Yoo Kyung
    Seong, Hyunyoung
    Lee, Kae Hong
    Jun, Seungwoo
    Choi, Jong Bum
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (11)
  • [28] Three-dimensional printed ultrasound and photoacoustic training phantoms for vasculature access
    Nikitichev, Daniil I.
    Xia, Wenfeng
    West, Simeon J.
    Desjardins, Adrien E.
    Ourselin, Sebastien
    Vercauteren, Tom
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [29] Three-dimensional printed laryngeal model for training in emergency airway access
    Smith, M.
    Drew, T.
    Reidy, B.
    McCaul, C.
    MacMahon, P.
    Jones, J. F. X.
    BRITISH JOURNAL OF ANAESTHESIA, 2018, 121 (01) : E8 - E9
  • [30] Three-dimensional printed hydrogel model vs cadaver: comparing inflatable penile prosthesis training and evaluation
    Saba, Patrick
    Cook, Andrew
    Melnyk, Rachel
    Schuler, Nathan
    Holler, Tyler
    Witthaus, Michael
    Ralph, David
    Collins, Justin
    Bettocchi, Carlo
    Van Renterghem, Koenraad
    Ghazi, Ahmed
    JOURNAL OF SEXUAL MEDICINE, 2023, : 1126 - 1132