Image Quality Comparison of Three 3D Mobile X-Ray Imaging Guidance Devices Used in Spine Surgery: A Phantom Study

被引:0
|
作者
Dabli, Djamel [1 ]
Salvat, Cecile [2 ]
Fitton, Isabelle [3 ]
Ty, Claire Van Ngoc [3 ]
Palanchon, Peggy [4 ]
Beregi, Jean-Paul [1 ]
Greffier, Joel [1 ]
Hadid-Beurrier, Lama [2 ]
机构
[1] Montpellier Univ, Nimes Univ Hosp, IMAGINE UR UM 103, Dept Med Imaging, F-30029 Nimes 9, France
[2] Lariboisiere Univ Hosp, Med Phys & Radiat Protect Dept, AP HP, F-75010 Paris, France
[3] Paris City Univ, Georges Pompidou European Hosp, Dept Radiol, AP HP, F-75015 Paris, France
[4] CHU Angers, Dept Radiodiagnost, 4 Rue Larrey, F-49933 Angers, France
关键词
3D imaging; spine surgery; noise power spectrum; task transfer function; BEAM COMPUTED-TOMOGRAPHY; CT; NAVIGATION; OPTIMIZATION; FLUOROSCOPY;
D O I
10.3390/s24216883
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An image-quality CT phantom was scanned with three different 3D X-ray imaging guidance devices in the operating theatre: O-Arm, Loop-X, and Airo TruCT. Default acquisition and reconstruction parameters for lumbar spine procedures were used on each device. The tube current was set to a dose level of around 27 mGy. A task-based image quality assessment was performed by calculating the noise power spectrum (NPS) and task transfer function (TTF). A detectability index (d') was calculated for three simulated bone lesions. The noise magnitude of the O-Arm was higher than the Airo TruCT, and the Loop-X had higher noise than the Airo TruCT. The highest average NPS frequency was for the O-Arm images, and the lowest was for the Loop-X. The TTFs at 50% values were similar for the Airo TruCT and Loop-X devices. Compared to Airo TruCT, the TTF at 50% value increased with the O-Arm by 53.12% and 41.20% for the Teflon and Delrin inserts, respectively. Compared to Airo TruCT, the d' value was lower with Loop-X by -26.73%, -27.02%, and -23.95% for lytic lesions, sclerotic lesions, and high-density bone, respectively. Each 3D-imaging spine surgery guidance device has its own strengths and weaknesses in terms of image quality. Cone-beam CT systems apparently offer the best compromise between noise and spatial resolution for spine surgery.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] An instrument for 3D x-ray nano-imaging
    Holler, M.
    Raabe, J.
    Diaz, A.
    Guizar-Sicairos, M.
    Quitmann, C.
    Menzel, A.
    Bunk, O.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (07):
  • [32] Glowing nanocrystals enable 3D X-ray imaging
    Albano N. Carneiro Neto
    Oscar L. Malta
    Nature, 2021, 590 : 396 - 397
  • [33] 3D x-ray reconstruction using lightfield imaging
    Saha, Sajib
    Tahtali, Murat
    Lambert, Andrew
    Pickering, Mark
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [34] Combining 3D Structured Light Imaging and Spine X-ray Data Improves Visualization of the Spinous Lines in the Scoliotic Spine
    Pasko, Slawomir
    Glinkowski, Wojciech
    APPLIED SCIENCES-BASEL, 2021, 11 (01): : 1 - 18
  • [35] Image quality and X-ray dose for translation reconstruction overview imaging of the spine, colon and legs
    Verdonck, B
    Nijlunsing, R
    Melman, N
    Geijer, H
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 500 - 505
  • [36] Influences on 3D image quality in a high-resolution X-ray laminography system
    Ebensperger, T.
    Rimbach, C.
    Zabier, S.
    Hanke, R.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [37] X-ray detection with 3D Medipix2 devices
    Fleta, C.
    Pennicard, D.
    Bates, R.
    O'Shea, V.
    Parkes, C.
    Lozano, M.
    Pellegrini, G.
    Marchal, J.
    Tartoni, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 89 - 91
  • [38] Forensic oral imaging quality of hand-held dental X-ray devices: Comparison of two image receptors and two devices
    Pittayapat, P.
    Thevissen, P.
    Fieuws, S.
    Jacobs, R.
    Willems, G.
    FORENSIC SCIENCE INTERNATIONAL, 2010, 194 (1-3) : 20 - 27
  • [39] Image quality and dose efficiency of high energy phase sensitive x-ray imaging: Phantom studies
    Wong, Molly Donovan
    Wu, Xizeng
    Liu, Hong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (03) : 321 - 334
  • [40] 3D imaging with an isocentric mobile C-arm - Comparison of image quality with spiral CT
    Kotsianos, D
    Wirth, S
    Fischer, T
    Euler, E
    Rock, C
    Linsenmaier, U
    Pfeifer, KJ
    Reiser, M
    EUROPEAN RADIOLOGY, 2004, 14 (09) : 1590 - 1595