Image Quality Comparison of Three 3D Mobile X-Ray Imaging Guidance Devices Used in Spine Surgery: A Phantom Study

被引:0
|
作者
Dabli, Djamel [1 ]
Salvat, Cecile [2 ]
Fitton, Isabelle [3 ]
Ty, Claire Van Ngoc [3 ]
Palanchon, Peggy [4 ]
Beregi, Jean-Paul [1 ]
Greffier, Joel [1 ]
Hadid-Beurrier, Lama [2 ]
机构
[1] Montpellier Univ, Nimes Univ Hosp, IMAGINE UR UM 103, Dept Med Imaging, F-30029 Nimes 9, France
[2] Lariboisiere Univ Hosp, Med Phys & Radiat Protect Dept, AP HP, F-75010 Paris, France
[3] Paris City Univ, Georges Pompidou European Hosp, Dept Radiol, AP HP, F-75015 Paris, France
[4] CHU Angers, Dept Radiodiagnost, 4 Rue Larrey, F-49933 Angers, France
关键词
3D imaging; spine surgery; noise power spectrum; task transfer function; BEAM COMPUTED-TOMOGRAPHY; CT; NAVIGATION; OPTIMIZATION; FLUOROSCOPY;
D O I
10.3390/s24216883
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An image-quality CT phantom was scanned with three different 3D X-ray imaging guidance devices in the operating theatre: O-Arm, Loop-X, and Airo TruCT. Default acquisition and reconstruction parameters for lumbar spine procedures were used on each device. The tube current was set to a dose level of around 27 mGy. A task-based image quality assessment was performed by calculating the noise power spectrum (NPS) and task transfer function (TTF). A detectability index (d') was calculated for three simulated bone lesions. The noise magnitude of the O-Arm was higher than the Airo TruCT, and the Loop-X had higher noise than the Airo TruCT. The highest average NPS frequency was for the O-Arm images, and the lowest was for the Loop-X. The TTFs at 50% values were similar for the Airo TruCT and Loop-X devices. Compared to Airo TruCT, the TTF at 50% value increased with the O-Arm by 53.12% and 41.20% for the Teflon and Delrin inserts, respectively. Compared to Airo TruCT, the d' value was lower with Loop-X by -26.73%, -27.02%, and -23.95% for lytic lesions, sclerotic lesions, and high-density bone, respectively. Each 3D-imaging spine surgery guidance device has its own strengths and weaknesses in terms of image quality. Cone-beam CT systems apparently offer the best compromise between noise and spatial resolution for spine surgery.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] 3D X-ray image guidance in interventional radiology
    Niessen, W. J.
    van de Kraats, E. B.
    Baert, S. A. M.
    van Walsum, Th.
    2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 1000 - 1003
  • [2] Comparison of high-resolution 3D X-ray microCT and tomosynthesis imaging: A breast phantom study
    Singh, Jolene M.
    Bui, Anthony H.
    Michaelson, James S.
    CANCER RESEARCH, 2014, 74 (19)
  • [3] Image Quality and Dose Comparison of 3 Mobile Intraoperative Three-Dimensional Imaging Systems in Spine Surgery
    Foster, Norah
    Shaffrey, Christopher
    Buchholz, Avery
    Turner, Raymond
    Yang, Lexie Zidanyue
    Niedzwiecki, Donna
    Goode, Allen
    WORLD NEUROSURGERY, 2022, 160 : E142 - E151
  • [4] An Optimised 3D Breast Phantom for X-Ray Breast Imaging Techniques
    Bliznakova, K.
    Kazakli, S.
    Pallikarakis, N.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 2455 - 2458
  • [5] Evaluation of a no-reference image quality metric for projection X-ray imaging using a 3D printed patient-specific phantom
    Buytaert, Dimitri
    Taeymans, Yves
    De Wolf, Daniel
    Bacher, Klaus
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 89 : 29 - 40
  • [6] 3D X-ray induced acoustic computed tomography: a phantom study
    Choi, Seongwook
    Lee, Donghyun
    Park, Eun-Yeong
    Min, Jung-Joon
    Lee, Changho
    Kim, Chulhong
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2020, 2020, 11240
  • [7] 3D X-RAY IMAGE COMPOSITION
    Armeanu, Constantin Catalin
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2016, 78 (01): : 309 - 320
  • [8] Image quality models for 2D and 3D x-ray imaging systems: A perspective vignette
    Siewerdsen, Jeffrey H. H.
    MEDICAL PHYSICS, 2023, 50 (S1) : 109 - 116
  • [9] Multiscale 3D X-ray imaging
    R. Joseph Kline
    Nature Electronics, 2019, 2 : 435 - 436
  • [10] Multiscale 3D X-ray imaging
    Kline, R. Joseph
    NATURE ELECTRONICS, 2019, 2 (10) : 435 - 436