On the effect of a tangential intake on the performance of natural dry draft cooling towers in crosswind conditions

被引:1
|
作者
Zakeri, Behzad [1 ]
Khashehchi, Morteza [2 ]
Rahmanivahid, Pooyan [3 ]
Heidari, Milad [3 ]
机构
[1] Univ Bologna, Dept Ind Engn, Forli, Italy
[2] Mil Technol Coll, Syst Engn Dept, Muscat, Oman
[3] Global Coll Engn & Technol GCET, Mech Engn Dept, POB 2546,CPO Ruwi 112, Muscat, Oman
关键词
Natural dry draft cooling towers; Swirling plume; Crosswind; Cooling enhancement; VERTICAL DELTA RADIATORS; FLOW; WIND; EFFICIENCY; IMPROVEMENT; DEFLECTORS;
D O I
10.1016/j.tsep.2024.103036
中图分类号
O414.1 [热力学];
学科分类号
摘要
Crosswind has a negative effect on the performance of natural draft dry cooling towers, NDDCTs, serving thermal power plants. This, in turn, lowers the efficiency of the thermal power plant as less heat can be rejected to the ambient air through the tower. This occurs due to interaction of cross wind and cooling tower structure. This phenomenon leads to generation of primary and secondary vortices inside the tower which located in leeward side (downwind side) and windward side (upwind side) of the tower, respectively. In an innovative interpretation of the challenge, this paper aims at directing the crosswind flow through the tower shell above the heat exchangers to assist the buoyancy-induced plume. In particular, the intake of the crosswind through the tower is utilized as a tangentially-induced swirl source to help the upward draft, and its penetration in the ambient air, enhancing the tower performance which otherwise would have been significantly deteriorated. Two independent approaches are presented to assess the proposed design quantitatively. CFD simulation of a small scale tower model has revealed significant performance improvement (in terms of natural draft blockage and outlet flow velocity) when the crosswind is allowed to penetrate the tower shell, through an opening on the tower side-wall, above the heat exchangers. Results of the simulations have been validated against the experimental data collected using the tests ran on an identical model, with and without the side opening, in a wind tunnel.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] The performance of natural draft dry cooling towers under crosswind: CFD study
    Al-Waked, R
    Behnia, M
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (02) : 147 - 161
  • [2] A review of the crosswind effect on the natural draft cooling towers
    Li, Xiaoxiao
    Gurgenci, Hal
    Guan, Zhiqiang
    Wang, Xurong
    Xia, Lin
    APPLIED THERMAL ENGINEERING, 2019, 150 : 250 - 270
  • [3] PERFORMANCE DETERIORATION MECHANISM ANALYSIS OF NATURAL DRAFT COOLING TOWERS UNDER CROSSWIND CONDITIONS
    Sun Feng-zhong
    Zhao Yuan-bin
    Gao Ming
    Chen You-liang
    Shi Yue-tao
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 2, 2012, : 287 - 291
  • [4] Windbreak walls reverse the negative effect of crosswind in short natural draft dry cooling towers into a performance enhancement
    Lu, Y.
    Guan, Z.
    Gurgenci, H.
    Zou, Z.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 63 : 162 - 170
  • [5] Experimental study of crosswind effects on the performance of small cylindrical natural draft dry cooling towers
    Lu, Yuanshen
    Guan, Zhiqiang
    Gurgenci, Hal
    Hooman, Kamel
    He, Suoying
    Bharathan, Desikan
    ENERGY CONVERSION AND MANAGEMENT, 2015, 91 : 238 - 248
  • [6] Positive impact of a tower inlet cover on natural draft dry cooling towers under crosswind conditions
    Liu, Quanlong
    Xia, Lin
    Hu, Mengqi
    Li, Xiaoxiao
    Mi, Zihao
    Jia, Junjie
    APPLIED THERMAL ENGINEERING, 2018, 139 : 283 - 294
  • [7] The effect of windbreak walls on the thermal performance of natural draft dry cooling towers
    Al-Waked, R
    Behnia, M
    HEAT TRANSFER ENGINEERING, 2005, 26 (08) : 50 - 62
  • [8] Investigation on heat exchanger arrangement in solar enhanced natural draft dry cooling towers under various crosswind conditions
    Xu, Mengfei
    He, Suoying
    Cheng, Jun
    Gao, Ming
    Lu, Yuanshen
    Hooman, Kamel
    Xu, Yi
    Geng, Zhe
    Zhang, Shuzhen
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [9] Adoption of enclosure and windbreaks to prevent the degradation of the cooling performance for a natural draft dry cooling tower under crosswind conditions
    Wang, Weiliang
    Zhang, Hai
    Li, Zheng
    Lv, Junfu
    Ni, Weidou
    Li, Yongsheng
    ENERGY, 2016, 116 : 1360 - 1369
  • [10] Impact of tower spacing on the performance of multiple short natural draft dry cooling towers for calm conditions
    Khamooshi, Mehrdad
    Anderson, Timothy N.
    Nates, Roy J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (04) : 885 - 894