Investigation on heat exchanger arrangement in solar enhanced natural draft dry cooling towers under various crosswind conditions

被引:14
|
作者
Xu, Mengfei [1 ]
He, Suoying [1 ]
Cheng, Jun [2 ]
Gao, Ming [1 ]
Lu, Yuanshen [3 ]
Hooman, Kamel [3 ]
Xu, Yi [1 ]
Geng, Zhe [4 ]
Zhang, Shuzhen [4 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Shandong Engn Lab High Efficiency Energy Conserva, Jinan 250061, Shandong, Peoples R China
[2] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
[3] Univ Queensland, Sch Mech & Min Engn, St Lucia, Qld 4072, Australia
[4] Shandong Hetong Informat Technol CO LTD, Jinan 250013, Shandong, Peoples R China
关键词
Solar enhanced natural draft dry cooling towers; Heat exchanger; Circular arrangement; Sawtooth arrangement; NUMERICAL-SIMULATION; PERFORMANCE ENHANCEMENT; THERMAL PERFORMANCE; WETTED MEDIA; OPTIMIZATION; DESIGN; FLOW; SYSTEM; LIMITATIONS;
D O I
10.1016/j.csite.2021.101505
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar enhanced natural draft dry cooling tower (SENDDCT) is a novel heat rejection device for thermal power plant, which uses solar energy to reheat the air after the heat exchanger and therefore improves the ventilation of the tower for performance enhancement. This paper develops 3-D models to compare the effects of circular/sawtooth arrangements of heat exchanger on cooling performance of a 140 m high SENDDCT. The result shows that sawtooth arrangement can improve the ventilation and heat dissipation rate of SENDDCTs. Under no crosswind condition, the flow field distributions of sawtooth and circular arrangements are similar in the tower. The ventilation and heat dissipation rate of sawtooth arrangement increases by 34.0 % and 46.8 % respectively when compared with circular arrangement under no crosswind condition. Under crosswind condition, the flow field of sawtooth arrangement is less affected by crosswind than that of circular arrangement. The ventilation rate and heat dissipation rate of sawtooth arrangement increases by 38.5 % and 65.0 % respectively when compared with circular arrangement at crosswind speed of 3 m/s. This study verifies that the sawtooth arrangement can weaken the crosswind effect and improve the cooling performance of SENDDCT and provides guidance for the optimal arrangement of heat exchanger for the SENDDCT.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] The performance of natural draft dry cooling towers under crosswind: CFD study
    Al-Waked, R
    Behnia, M
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (02) : 147 - 161
  • [2] Positive impact of a tower inlet cover on natural draft dry cooling towers under crosswind conditions
    Liu, Quanlong
    Xia, Lin
    Hu, Mengqi
    Li, Xiaoxiao
    Mi, Zihao
    Jia, Junjie
    APPLIED THERMAL ENGINEERING, 2018, 139 : 283 - 294
  • [3] On the effect of a tangential intake on the performance of natural dry draft cooling towers in crosswind conditions
    Zakeri, Behzad
    Khashehchi, Morteza
    Rahmanivahid, Pooyan
    Heidari, Milad
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 56
  • [4] PERFORMANCE DETERIORATION MECHANISM ANALYSIS OF NATURAL DRAFT COOLING TOWERS UNDER CROSSWIND CONDITIONS
    Sun Feng-zhong
    Zhao Yuan-bin
    Gao Ming
    Chen You-liang
    Shi Yue-tao
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 2, 2012, : 287 - 291
  • [5] Study of Heat Rejection in Triple Natural Draft Dry Cooling Towers under Crosswind Using Radiator-type Windbreakers
    Hozhabr, Amir
    Radi, Ramin
    Chenari, Hossein
    Choganil, Arash
    Esmaeelipour, Masoud
    ADVANCED MATERIALS, MECHANICS AND INDUSTRIAL ENGINEERING, 2014, 598 : 265 - 270
  • [6] Numerical investigation of swirl effects on a short natural draft dry cooling tower under windless and crosswind conditions
    Dai, Yuchen
    Lu, Yuanshen
    Klimenko, Alexander Y.
    Wang, Ying
    Hooman, Kamel
    APPLIED THERMAL ENGINEERING, 2021, 188
  • [7] 3D numerical study using three novel windbreak walls in natural draft dry cooling towers for performance enhancement under various crosswind conditions
    Shirazi, Mehran
    Jahangiri, Ali
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 25
  • [8] Experimental study of crosswind effects on the performance of small cylindrical natural draft dry cooling towers
    Lu, Yuanshen
    Guan, Zhiqiang
    Gurgenci, Hal
    Hooman, Kamel
    He, Suoying
    Bharathan, Desikan
    ENERGY CONVERSION AND MANAGEMENT, 2015, 91 : 238 - 248
  • [9] Numerical study on water distribution of natural draft wet cooling towers under crosswind
    Bai, Guanghui
    Chang, Hao
    Li, Wei
    Chen, Yongji
    Li, Guojun
    MECHANICAL ENGINEERING JOURNAL, 2022, 9 (04):
  • [10] The effect of the heat exchanger arrangement and wind-break walls on the performance of natural draft dry-cooling towers subjected to cross-winds
    duPreez, AF
    Kroger, DG
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1995, 58 (03) : 293 - 303