Investigation on heat exchanger arrangement in solar enhanced natural draft dry cooling towers under various crosswind conditions

被引:14
|
作者
Xu, Mengfei [1 ]
He, Suoying [1 ]
Cheng, Jun [2 ]
Gao, Ming [1 ]
Lu, Yuanshen [3 ]
Hooman, Kamel [3 ]
Xu, Yi [1 ]
Geng, Zhe [4 ]
Zhang, Shuzhen [4 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Shandong Engn Lab High Efficiency Energy Conserva, Jinan 250061, Shandong, Peoples R China
[2] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
[3] Univ Queensland, Sch Mech & Min Engn, St Lucia, Qld 4072, Australia
[4] Shandong Hetong Informat Technol CO LTD, Jinan 250013, Shandong, Peoples R China
关键词
Solar enhanced natural draft dry cooling towers; Heat exchanger; Circular arrangement; Sawtooth arrangement; NUMERICAL-SIMULATION; PERFORMANCE ENHANCEMENT; THERMAL PERFORMANCE; WETTED MEDIA; OPTIMIZATION; DESIGN; FLOW; SYSTEM; LIMITATIONS;
D O I
10.1016/j.csite.2021.101505
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar enhanced natural draft dry cooling tower (SENDDCT) is a novel heat rejection device for thermal power plant, which uses solar energy to reheat the air after the heat exchanger and therefore improves the ventilation of the tower for performance enhancement. This paper develops 3-D models to compare the effects of circular/sawtooth arrangements of heat exchanger on cooling performance of a 140 m high SENDDCT. The result shows that sawtooth arrangement can improve the ventilation and heat dissipation rate of SENDDCTs. Under no crosswind condition, the flow field distributions of sawtooth and circular arrangements are similar in the tower. The ventilation and heat dissipation rate of sawtooth arrangement increases by 34.0 % and 46.8 % respectively when compared with circular arrangement under no crosswind condition. Under crosswind condition, the flow field of sawtooth arrangement is less affected by crosswind than that of circular arrangement. The ventilation rate and heat dissipation rate of sawtooth arrangement increases by 38.5 % and 65.0 % respectively when compared with circular arrangement at crosswind speed of 3 m/s. This study verifies that the sawtooth arrangement can weaken the crosswind effect and improve the cooling performance of SENDDCT and provides guidance for the optimal arrangement of heat exchanger for the SENDDCT.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] DESIGN OF SOLAR ENHANCED NATURAL DRAFT DRY COOLING TOWER FOR SOLAR THERMAL POWER PLANTS
    Guan, Zhiqiang
    Gurgenci, Hal
    Zou, Zheng
    JOURNAL OF THE INTERNATIONAL ASSOCIATION FOR SHELL AND SPATIAL STRUCTURES, 2016, 57 (01): : 97 - 103
  • [42] Natural draft direct dry cooling system performance at various application scales under windless and windy conditions
    Strydom, Wian
    Pretorius, Johannes
    Hoffmann, Jaap
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [43] Effects of solar radiation intensity and ambient temperature on heat transfer performance of solar enhanced natural draft dry cooling tower
    Xin, Guanglei
    Zhu, Jialing
    Jiang, Feng
    Zhao, Yangyang
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (01): : 41 - 46
  • [44] Study on the influence of building aerodynamic shadows on the heat transfer performance of natural draft dry cooling towers
    Zhao, Jincheng
    Ma, Mingrui
    Wang, Zhichao
    Tan, Dunhu
    Chen, Lin
    Zhang, Feng
    Han, Xu
    Wang, Zhi
    AIP ADVANCES, 2023, 13 (11)
  • [45] Impact of tower spacing on the performance of multiple short natural draft dry cooling towers for calm conditions
    Khamooshi, Mehrdad
    Anderson, Timothy N.
    Nates, Roy J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (04) : 885 - 894
  • [46] Investigation into the positive effects of wind deflectors on natural draft wet cooling towers under crosswinds
    Chen, Youliang
    Cheng, Shi
    Zi, Pingyang
    Liu, Zhongyuan
    Fan, Rong
    2020 6TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2020, 508
  • [47] PERFORMANCE ANALYSIS OF HEAT EXCHANGER FOR COOLING APPLICATIONS UNDER DRY AND WET CONDITIONS
    Kumar, Manav
    Kumar, K. Kiran
    Mondal, Sharifuddin
    HEAT TRANSFER RESEARCH, 2023, 54 (09) : 27 - 48
  • [48] A novel natural draft dry cooling system with bilaterally arranged air-cooled heat exchanger
    Kong, Yanqiang
    Wang, Weijia
    Yang, Lijun
    Du, Xiaoze
    Yang, Yongping
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 112 : 318 - 334
  • [49] Triangularly arranged heat exchanger bundles to restrain wind effects on natural draft dry cooling system
    Liao, H. T.
    Yang, L. J.
    Du, X. Z.
    Yang, Y. P.
    APPLIED THERMAL ENGINEERING, 2016, 99 : 313 - 324
  • [50] Influence of ambient conditions and water flow on the performance of pre-cooled natural draft dry cooling towers
    He, Suoying
    Guan, Zhiqiang
    Gurgenci, Hal
    Jahn, Ingo
    Lu, Yuanshen
    Alkhedhair, Abdullah M.
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 621 - 631