Effect of Hot Junction Size on the Temperature Measurement of Proton Exchange Membrane Fuel Cells Using NiCr/NiSi Thin-Film Thermocouple Sensors

被引:0
|
作者
Guo, Huijin [1 ]
Liu, Zhihui [2 ]
Guo, Tengda [2 ]
Sun, Yi [2 ,3 ]
Shen, Kai [4 ]
Wang, Bi [5 ]
Cheng, Yongjun [6 ]
Wang, Yuming [2 ]
Ma, Tiancai [1 ]
Wang, Zixi [2 ]
Ding, Wanyu [7 ]
机构
[1] Tongji Univ, Sch Automot Studies, Shanghai 201804, Peoples R China
[2] Tsinghua Univ, State Key Lab Tribol Adv Equipment, Beijing 100084, Peoples R China
[3] Dalian Jiaotong Univ, Coll Mech Engn, Dalian 116028, Peoples R China
[4] Dalian Jiaotong Univ, Minist Educ, Engn Res Ctr Continuous Extrus, Dalian 116028, Peoples R China
[5] State Key Lab High end Compressor & Syst Technol, Hefei 230031, Peoples R China
[6] Lab Low Frequency Electromagnet Commun Technol WMC, Wuhan 430200, Peoples R China
[7] Dalian Jiaotong Univ, Coll Mat Sci & Engn, Dalian 116028, Peoples R China
基金
国家重点研发计划;
关键词
Seebeck effect; thin film thermocouple; proton exchange membrane fuel cell; heat transfer; failure analysis; SURFACE; HEAT; AIR;
D O I
10.3390/mi15111375
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the process of using thin-film thermocouples for contact measurement of the reaction temperature in proton exchange membrane fuel cells (PEMFC), the impact of thin-film thermocouple volume on the system's reaction temperature field variation, reaction efficiency, and the lifespan of thermocouples under these conditions is not thoroughly studied. Using magnetron sputtering technology, NiCr/NiSi thin-film thermocouples (NiCr/NiSi TFTCs) with different junction sizes were fabricated on the proton exchange membrane (PEM). These NiCr/NiSi TFTCs exhibit excellent compactness, with thickness and planar dimensions in the micrometer range. When PEMFCs are equipped with built-in NiCr/NiSi TFTCs of different hot junction sizes, the time required for the system to reach a steady state varies with the size of the hot junction, with smaller hot junction sizes reaching a steady state more quickly. In a 500-h continuous operation test, the failure rates of NiCr/NiSi TFTCs also vary based on the hot junction size. Both smaller and larger hot junction sizes have relatively higher failure rates, whereas medium-sized junctions have a lower failure rate. These extensive and repetitive comparative experiments provide significant reference value for the size design of TFTCs operating inside PEMFCs, promoting both industrial production and scientific research.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Thin film electrodes from Pt nanorods supported on aligned N-CNTs for proton exchange membrane fuel cells
    Mardle, Peter
    Ji, Xiaochao
    Wu, Jing
    Guan, Shaoliang
    Dong, Hanshan
    Du, Shangfeng
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2020, 260 (260)
  • [42] Analyzing characteristic and modeling of high-temperature proton exchange membrane fuel cells with CO poisoning effect
    Lei, Gang
    Zheng, Hualin
    Zhang, Jun
    Chin, Cheng Siong
    Xu, Xinhai
    Zhou, Weijiang
    Zhang, Caizhi
    ENERGY, 2023, 282
  • [43] Investigation of non-uniform temperature distribution in air-cooled proton exchange membrane fuel cells with multizone temperature measurement
    Yu, Wei
    Sun, Liangbo
    Zhu, Wenli
    Li, Yana
    Pei, Houchang
    Xing, Lu
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2024, 21 (10) : 2228 - 2238
  • [44] Effect of carbon fiber cloth with different structure on the performance of low temperature proton exchange membrane fuel cells
    Liu, Ching-Han
    Ko, Tse-Hao
    Kuo, Wen-Shyong
    Chou, Huan-Kai
    Chang, Hsu-Wen
    Liao, Yuan-Kai
    JOURNAL OF POWER SOURCES, 2009, 186 (02) : 450 - 454
  • [45] Effect of Ni proportion on the performance of proton exchange membrane fuel cells using PtNi/C electrocatalysts
    Fernanda T. da Silva
    Vicenti A. Dalmazzo
    Márcia R. Becker
    Michèle O. de Souza
    Roberto F. de Souza
    Emilse M. A. Martini
    Ionics, 2014, 20 : 381 - 388
  • [46] Effect of Ni proportion on the performance of proton exchange membrane fuel cells using PtNi/C electrocatalysts
    da Silva, Fernanda T.
    Dalmazzo, Vicenti A.
    Becker, Marcia R.
    de Souza, Michele O.
    de Souza, Roberto F.
    Martini, Emilse M. A.
    IONICS, 2014, 20 (03) : 381 - 388
  • [47] Experimental Study on the Effect of Hydrogen Sulfide on High-Temperature Proton Exchange Membrane Fuel Cells by Using Electrochemical Impedance Spectroscopy
    Kang, Ren-Jun
    Chen, Yong-Song
    CATALYSTS, 2018, 8 (10):
  • [48] Combined heat and power using high-temperature proton exchange membrane fuel cells for housing facilities
    Sanz i Lopez, Victor
    Lopez, Guillermo
    Costa-Castello, Ramon
    Batlle, Carles
    2021 26TH IEEE INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION (ETFA), 2021,
  • [49] High-Temperature Proton-Exchange-Membrane Fuel Cells Using an Ether-Containing Polybenzimidazole Membrane as Electrolyte
    Li, Jin
    Li, Xiaojin
    Zhao, Yun
    Lu, Wangting
    Shao, Zhigang
    Yi, Baolian
    CHEMSUSCHEM, 2012, 5 (05) : 896 - 900
  • [50] Temperature Distributions Measurement of High Intensity Focused Ultrasound using a Thin-film Thermocouple Array and Estimation of Thermal Error caused by Viscous Heating
    Matsuki, Kosuke
    Narumi, Ryuta
    Azuma, Takashi
    Yoshinaka, Kiyoshi
    Sasaki, Akira
    Okita, Kohei
    Takagi, Shu
    Matsumoto, Yoichiro
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3722 - 3725