Effect of Hot Junction Size on the Temperature Measurement of Proton Exchange Membrane Fuel Cells Using NiCr/NiSi Thin-Film Thermocouple Sensors

被引:0
|
作者
Guo, Huijin [1 ]
Liu, Zhihui [2 ]
Guo, Tengda [2 ]
Sun, Yi [2 ,3 ]
Shen, Kai [4 ]
Wang, Bi [5 ]
Cheng, Yongjun [6 ]
Wang, Yuming [2 ]
Ma, Tiancai [1 ]
Wang, Zixi [2 ]
Ding, Wanyu [7 ]
机构
[1] Tongji Univ, Sch Automot Studies, Shanghai 201804, Peoples R China
[2] Tsinghua Univ, State Key Lab Tribol Adv Equipment, Beijing 100084, Peoples R China
[3] Dalian Jiaotong Univ, Coll Mech Engn, Dalian 116028, Peoples R China
[4] Dalian Jiaotong Univ, Minist Educ, Engn Res Ctr Continuous Extrus, Dalian 116028, Peoples R China
[5] State Key Lab High end Compressor & Syst Technol, Hefei 230031, Peoples R China
[6] Lab Low Frequency Electromagnet Commun Technol WMC, Wuhan 430200, Peoples R China
[7] Dalian Jiaotong Univ, Coll Mat Sci & Engn, Dalian 116028, Peoples R China
基金
国家重点研发计划;
关键词
Seebeck effect; thin film thermocouple; proton exchange membrane fuel cell; heat transfer; failure analysis; SURFACE; HEAT; AIR;
D O I
10.3390/mi15111375
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the process of using thin-film thermocouples for contact measurement of the reaction temperature in proton exchange membrane fuel cells (PEMFC), the impact of thin-film thermocouple volume on the system's reaction temperature field variation, reaction efficiency, and the lifespan of thermocouples under these conditions is not thoroughly studied. Using magnetron sputtering technology, NiCr/NiSi thin-film thermocouples (NiCr/NiSi TFTCs) with different junction sizes were fabricated on the proton exchange membrane (PEM). These NiCr/NiSi TFTCs exhibit excellent compactness, with thickness and planar dimensions in the micrometer range. When PEMFCs are equipped with built-in NiCr/NiSi TFTCs of different hot junction sizes, the time required for the system to reach a steady state varies with the size of the hot junction, with smaller hot junction sizes reaching a steady state more quickly. In a 500-h continuous operation test, the failure rates of NiCr/NiSi TFTCs also vary based on the hot junction size. Both smaller and larger hot junction sizes have relatively higher failure rates, whereas medium-sized junctions have a lower failure rate. These extensive and repetitive comparative experiments provide significant reference value for the size design of TFTCs operating inside PEMFCs, promoting both industrial production and scientific research.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Effect of water phase change on temperature distribution in proton exchange membrane fuel cells
    Ebrahim Afshari
    Seyed Ali Jazayeri
    Yaser Mollayi Barzi
    Heat and Mass Transfer, 2010, 46 : 1295 - 1305
  • [22] Effect of defective cells on the temperature distribution of a proton exchange membrane fuel cell stack
    Liu, Huaiyu
    Sun, Kai
    Tao, Xingxiao
    Zeng, Zhen
    Li, Qifeng
    Che, Zhizhao
    Wang, Tianyou
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 85 : 270 - 280
  • [23] Effect of water phase change on temperature distribution in proton exchange membrane fuel cells
    Afshari, Ebrahim
    Jazayeri, Seyed Ali
    Barzi, Yaser Mollayi
    HEAT AND MASS TRANSFER, 2010, 46 (11-12) : 1295 - 1305
  • [24] Measurement of humidity distribution in a proton exchange membrane fuel cell using channel embedded humidity sensors
    Dept. of Mechanical Engineering, Hannam Univ, Korea, Republic of
    Trans. Korean Soc. Mech. Eng., B, 5 (397-403): : 397 - 403
  • [25] HIGH-TEMPERATURE THERMOCOUPLE AND HEAT-FLUX GAUGE USING A UNIQUE THIN FILM-HARDWARE HOT JUNCTION
    LIEBERT, CH
    HOLANDA, R
    HIPPENSTEELE, SA
    ANDRACCHIO, CA
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1985, 107 (04): : 938 - 944
  • [26] Investigating the effect of operating temperature on dynamic behavior of droplets for proton exchange membrane fuel cells
    Hirpara, Viral
    Patel, Virat
    Zhang, Yuzhou
    Anderson, Ryan
    Zhu, Ning
    Zhang, Lifeng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (27) : 14145 - 14155
  • [27] Effect of Flow Field with Baffles on Performance of High Temperature Proton Exchange Membrane Fuel Cells
    Li, Shian
    Zhang, Shuqian
    Shen, Qiuwan
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2025, 13 (03)
  • [28] Improved Electrodes for High Temperature Proton Exchange Membrane Fuel Cells using Carbon Nanospheres
    Zamora, Hector
    Plaza, Jorge
    Canizares, Pablo
    Lobato, Justo
    Rodrigo, Manuel A.
    CHEMSUSCHEM, 2016, 9 (10) : 1187 - 1193
  • [29] METHOD AND MEASUREMENT OF ADIABATIC WALL TEMPERATURE DOWNSTREAM OF A HIGH PRESSURE TURBINE USING THIN-FILM SENSORS
    Pinilla, V.
    Solano, J. P.
    Paniagua, G.
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 5, PTS A AND B, 2012, : 1701 - 1708
  • [30] Effect of particle size on the activity and durability of the Pt/C electrocatalyst for proton exchange membrane fuel cells
    Xu, Zhuang
    Zhang, Huamin
    Zhong, Hexiang
    Lu, Qiuhong
    Wang, Yunfeng
    Su, Dangsheng
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2012, 111 : 264 - 270