Structures of Giant Magnetoresistance Sensors for Magnetic Bead Detection

被引:0
|
作者
Tan, Xi [1 ]
Li, Zhixue [1 ]
Gao, Xiaoping [2 ]
Wu, Huiliang [1 ]
Huang, Dandan [1 ]
Liu, Weining [1 ]
Zhao, Mingyang [1 ]
Cheng, Qionglin [1 ]
Ren, Yaqian [1 ]
Chen, Yawen [1 ]
Yi, Ming [1 ]
Ding, Qi [1 ]
Song, Yuzhe [2 ]
Li, Hairong [1 ]
机构
[1] Lanzhou Univ, Sch Phys Sci & Technol, Lanzhou 730000, Peoples R China
[2] Gansu Acad Sci, Inst Sensor Technol, Key Lab Sensor & Sensing Technol, Lanzhou 730000, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Magnetic sensors; Perpendicular magnetic anisotropy; Magnetic moments; Strips; Biosensors; Resistance; Giant magnetoresistance (GMR) sensor; magnetic bead; signal-to-noise ratio (SNR); simulation; GMR SENSORS; BIOSENSORS; NANOPARTICLES; IMMUNOASSAY; CHIP;
D O I
10.1109/JSEN.2024.3426616
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study explores the fabrication of giant magnetoresistance (GMR) sensors through the microelectromechanical systems (MEMS) process. Moreover, it investigates the magnetic properties of these sensors across various structural parameters. In particular, the study evaluates the effects of variations in four specific parameters of a GMR sensor on magnetic bead signals, aiming to achieve high sensitivity of the sensor and a high signal-to-noise ratio (SNR) output. Dual ac modulation is employed for magnetic bead signal detection. The results indicate that a sensor with a linewidth of 1 mu m and line spacing of 5 mu m exhibits the highest signal output and a higher SNR.
引用
收藏
页码:36587 / 36593
页数:7
相关论文
共 50 条
  • [41] Quantitative detection of magnetic particles in a chromatographic membrane by a giant magnetoresistance sensor
    Lee, Kisu
    Lee, Seungkyo
    Kim, Jeong-Ryul
    Cho, B. K.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (07)
  • [42] Contactless potentiometer based on giant magnetoresistance sensors
    Clemens, W
    vandenBerg, HAM
    Rupp, G
    Schelter, W
    Vieth, M
    Wecker, J
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) : 4310 - 4312
  • [43] A novel CMOS transducer for giant magnetoresistance sensors
    Luong, Van Su
    Lu, Chih-Cheng
    Yang, Jing-Wen
    Jeng, Jen-Tzong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [44] Quantitative detection of magnetic particles in a chromatographic membrane by a giant magnetoresistance sensor
    Lee, Kisu
    Lee, Seungkyo
    Kim, Jeong-Ryul
    Cho, B.K.
    Journal of Applied Physics, 2009, 105 (07):
  • [45] Development of Sensors Based on Giant Magnetoresistance Material
    Djamal, Mitra
    Ramli
    ISEEC, 2012, 32 : 60 - 68
  • [46] Enhancing the Linearity of Giant Magnetoresistance Sensors by Magnetic Anisotropic Design and Low Temperature Annealing
    Wang, Liqian
    Hu, Zhongqiang
    Wu, Jingen
    Zhao, Xinger
    Guan, Mengmeng
    Wang, Chenying
    Luo, Ningzhao
    Xian, Dan
    Wang, Zhiguang
    Zhou, Ziyao
    Jiang, Zhuangde
    Liu, Ming
    IEEE SENSORS JOURNAL, 2021, 21 (24) : 27393 - 27399
  • [47] Controlled trapping and detection of magnetic particles by a magnetic microactuator and a giant magnetoresistance (GMR) sensor
    Giouroudi, Ioanna
    Gooneratne, Chinthaka
    Kokkinis, Georgios
    MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS III, 2014, 605 : 352 - 355
  • [48] Domain wall contribution to giant magnetoresistance of magnetic multilayer structures with slight roughness
    Morosov, AI
    Sigov, AS
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1997, 165 (1-3) : 367 - 369
  • [49] Giant Magnetoresistance (GMR) Sensors Based on Co/Cu Multilayers for Biomaterial Detection Applications
    Suharyadi, Edi
    Pardede, Indra
    Hasibuan, Ferawati A.
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 566 - 571
  • [50] Giant Thermal Magnetoresistance in Plasmonic Structures
    Latella, Ivan
    Ben-Abdallah, Philippe
    PHYSICAL REVIEW LETTERS, 2017, 118 (17)