Development of microcomputer protection and measuring-control device for 35 kV distribution line

被引:0
|
作者
Zhang T. [1 ]
Zhai Y. [1 ]
Wu Z. [2 ]
机构
[1] School of Electronic Information and Electrical Engineering, Anyang Institute of Technology, Henan, Anyang
[2] XJ Electric Co., Ltd., Henan, Xuchang
来源
Zhai, Yafang (dqxyzyf@126.com) | 1600年 / Inderscience Publishers卷 / 12期
关键词
35; kV; AD7606; Distribution line; Electric parameter; MB9FB618S; Measuring-control device; Microcomputer protection; Protection logic; Real-time detection; SN65LBC184D;
D O I
10.1504/IJICA.2021.119326
中图分类号
学科分类号
摘要
According to the research status of a 35 kV microcomputer protection device, a new type of microcomputer protection and measuring-control device was designed to address common electrical failures during the running of 35 kV distribution line. In this device, a 32-bit high performance embedded microprocessor was used as the control centre, and the AD 7606 was used for analogue-to-digital conversion, which improves the data sampling accuracy. The device could realise real-time detection on electric parameters such as current, voltage, active power, reactive power, and provide the distribution line different protections, including current direction protection, over-current acceleration protection, zero sequence current direction protection and under frequency load shedding. In general, this device combines functions of protection, measurement, control and communication. With the characteristics of simple structure, easy operation, fully functioned and high reliability, this device also has high application value. Copyright © 2021 Inderscience Enterprises Ltd.
引用
收藏
页码:304 / 311
页数:7
相关论文
共 50 条
  • [31] Application of the microcomputer-based protection type LFP-941J to fast tripping of 110 kV transmission line
    Lu, Zhili
    Liang, Qiang
    Shen, Guorong
    Jing, Yong
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 1998, 22 (11): : 82 - 84
  • [32] Interface between 500 kV microcomputer-based line protection and ABB equipment in Ling'ao nuclear power station
    Kong, W.
    Han, H.
    He, X.
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2001, 25 (22):
  • [33] Development of high precision damping device for Baume degree on-line measuring
    Sun, Guangwei
    Jiang, Zhijian
    Mou, Yingfeng
    Li, Liyan
    2002, Science Press (23):
  • [34] Development of an On-line Monitoring System of Vacuum Degree in 35kV Vacuum Tube
    Xu, Lei
    Xu, Wen
    Liu, ChangZheng
    Liu, Zongjie
    Li, Juelong
    Ye, Haifeng
    Jiang, Xiuchen
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1994 - 2002
  • [35] The Research on Development of EHV Line Longitudinal Protection Debugging Device in Intelligent Substation
    Li, Rui
    Song, Shuyong
    Ma, Zhenguo
    Zhang, Yue
    MODERN TECHNOLOGIES IN MATERIALS, MECHANICS AND INTELLIGENT SYSTEMS, 2014, 1049 : 695 - +
  • [36] The Non-unit Transient-based Protection and Its Settings for 35 kV Distribution Lines Based on the Line Boundary Characteristic of Electronic Voltage Transformer
    Wu Y.
    Li Z.
    Xiao S.
    Huang Z.
    Li Z.
    Wei F.
    Lin X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (12): : 4666 - 4681
  • [37] Development of Current Detection Terminal of Wireless 10kV Distribution Line
    Du Peidong
    Wang Weizhou
    Liu Fuchao
    Zheng Jingjing
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND INTELLIGENT SYSTEMS (ICMEIS 2015), 2015, 26 : 36 - 41
  • [38] Development of a new on-line monitoring device for distribution network lines
    Tan W.
    Zhang W.
    Quan L.
    Chen Y.
    Song G.
    Zhang M.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (01): : 158 - 165
  • [39] Development of an arc-extinguishing lightning protection gap for 35kV overhead power lines
    Wang, Ju-feng
    Wu, Dong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (11) : 2897 - 2901
  • [40] Coordination of Relay Protection Operating Values with Various Current – Time Characteristics in 6 – 35 kV Distribution Networks
    M. V. Sharygin
    A. M. Alshaheri
    Power Technology and Engineering, 2025, 58 (5) : 866 - 871