Selectivity Enhancement Scheme for Zero-sequence Current Protection Based on Distance Relay for High-resistance Grounding Fault

被引:0
|
作者
Li, Yong [1 ,2 ]
Li, Yinhong [3 ,4 ]
Liu, Huanzhang [1 ,2 ]
Liu, Yang [1 ,2 ]
机构
[1] Central China Branch of State Grid Corporation of China, Wuhan,430077, China
[2] Lamor Innovation Studio of Liu Huanzhang, Wuhan,430077, China
[3] School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan,430074, China
[4] State Key Laboratory of Advanced Electromagnetic Technology, Huazhong University of Science and Technology, Wuhan,430074, China
关键词
Electric equipment protection - Electric grounding - Electric power system protection - Short circuit currents - Site selection;
D O I
10.7500/AEPS20240228008
中图分类号
学科分类号
摘要
The last section of zero-sequence current protection of AC line adopts 300 A, which has the risk of disordered tripping. Therefore, a new principle of high-resistance grounding distance relay based on zero-sequence reactance line and non-fault phase polarization is proposed. The relay adopts the technical route of phase selection before measurement. The phase selection element combines zero-sequence reactance line and non-fault phase polarization method to form a variety of combined criteria to complete the phase selection. Due to the phase difference between the zero-sequence current at the protection installation site and the zero-sequence current at the fault point, the zero-sequence reactance lines of the single-phase grounding fault phase and the leading phase of the inter-phase grounding fault have aliasing region when the fault point is near the setting point. The large variation of the operation voltage of the non-fault phase is not conducive to distinguishing the two types of faults in the aliasing region, and thus the phase selection element is divided into low-resistance module and high-resistance module. The low-resistance module adopts the zero-sequence reactance line with the downward bias, which is used to identify the near-end and low-resistance short circuit. With the assistance of the low-resistance module, the high-resistance module only needs to deal with the faults near the setting point, which reduces the difficulty in distinguishing the two types of faults. After phase selection, the operation voltage before fault is obtained by non-fault phase polarization method, so as to determine the operation characteristics of the relay. The ability of high-resistance distance relay to withstand the transition resistance is far beyond the requirements of the regulations, which improves the selectivity of grounding backup protection to high-resistance faults. © 2024 Automation of Electric Power Systems Press. All rights reserved.
引用
收藏
页码:169 / 179
相关论文
共 50 条
  • [41] Induction Motor Fault Diagnosis Based on Zero-Sequence Current Analysis
    Duda, Arkadiusz
    Drozdowski, Piotr
    ENERGIES, 2020, 13 (24)
  • [42] Fault line detection method for a flexible grounding system based on a zero-sequence current amplitude ratio multiplication coefficient
    Zhou Y.
    Tang T.
    Zeng X.
    Luo C.
    Yang Z.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (23): : 112 - 120
  • [43] Single- phase Grounding Fault Detection Method in Resonant Grounding System Based on the Ratio of Instantaneous Zero-Sequence Voltage to Current Derivative
    Sun, Tiepeng
    Liu, Ying
    Tan, Huidan
    Tian, Junyang
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 1012 - 1016
  • [44] Differential protection based on zero-sequence voltages for generator stator ground fault
    Tai Nengling
    Stenzel, Juergen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 116 - 121
  • [45] A new method for fault line selection based on correlation between zero-sequence voltage in bus and zero-sequence current in feeders
    Xiang, Yunkun
    Jiang, Yun
    Ning, Yuanzhi
    Tao, Fang
    Liu, Bohan
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1196 - 1199
  • [46] MICROPROCESSOR-BASED ALGORITHM FOR HIGH-RESISTANCE EARTH-FAULT DISTANCE PROTECTION - REPLY
    YANG, QS
    MORRISON, IF
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1985, 132 (02) : 95 - 95
  • [47] A fault section location method based on the slope similarity of zero-sequence current waveform for the non-effectively grounding system
    Zhang, Xinhui
    Guo, Aiyu
    Hu, Changyong
    Xie, Shuyu
    Wang, Jinghua
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2025, 165
  • [48] Frequency Response Testing of Zero-Sequence Current Transformers for Mining Ground Fault Protection Relays
    Kulinski, Krzysztof
    Heyduk, Adam
    INTERNATIONAL JOURNAL OF ELECTRONICS AND TELECOMMUNICATIONS, 2020, 66 (04) : 701 - 705
  • [49] Single Phase To Ground Fault Location Based On Phase Of Zero-sequence Current
    Li Jinjie
    Qi Yulin
    Gao Qiaomei
    Sun Shihao
    2013 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2013, : 856 - 859
  • [50] Detection and Discrimination of Interturn Fault and High-Resistance Connection Fault in PMSM Based on Deviation Angle of Zero Sequence Voltage
    Zhu, Ying
    Cai, Shouguo
    Li, Bin
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (03): : 7623 - 7632