A new method for fault line selection based on correlation between zero-sequence voltage in bus and zero-sequence current in feeders

被引:0
|
作者
Xiang, Yunkun [1 ]
Jiang, Yun
Ning, Yuanzhi
Tao, Fang [1 ]
Liu, Bohan [1 ]
机构
[1] Changsha Univ Sci & Technol, Coll Elect & Informat Engn, Changsha, Hunan, Peoples R China
关键词
Keywords resonant grounding system; fault line selection; zero-sequence voltage in bus; correlation coefficient;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
It is difficult to select the fault line due to the weak current when the single-phase grounding fault occurs in the resonant grounding system. A new method based on correlation between zero-sequence voltage in bus and zero-sequence current in feeders is proposed in this paper. The correlation coefficient is less than zero because the polarity of zero-sequence voltage and zero-sequence current is opposite in fault line, and correlation coefficient is large than zero because the polarity in sound line is same. Therefore, the feeder what corresponding to the minimum correlation coefficient is the fault line. Most simulation results show that in resonant grounding system, compared with the integrated correlation coefficient analysis between pure fault components of zero-sequence current from every line, this method can be applied to select fault line more better, and misjudgment will not be caused.(1)
引用
收藏
页码:1196 / 1199
页数:4
相关论文
共 50 条
  • [1] Optimization of zero-sequence voltage compensation for zero-sequence directional elements
    Xu, Hao
    Yin, Chaoyong
    Dong, Guoqin
    Wang, Shannuo
    Xu, Liqiang
    Ouyang, Fan
    Zhu, Weijun
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 197
  • [2] Zero-Sequence Current Suppression Method for Fault-Tolerant OW-PMSM Drive With Asymmetric Zero-Sequence Voltage Injection
    Zhang, Chong
    Gan, Chun
    Ni, Kai
    Yu, Zhiyue
    Chen, Yu
    Shi, Haochen
    Qu, Ronghai
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (03) : 2351 - 2362
  • [3] Single-phase grounding fault line selection method based on zero-sequence current increment
    Hao, Bai
    ENERGY REPORTS, 2022, 8 : 305 - 312
  • [4] Grounding fault location method based on waveform similarity of zero-sequence current
    You X.
    Ge X.
    Wu P.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (14): : 125 - 130
  • [5] Analysis of influence of unbalanced zero-sequence current on pilot zero-sequence protection and its countermeasures
    Tian, Baojiang
    Zhang, Taisheng
    Chen, Jun
    Zang, Rui
    Liao, Xiaoyu
    Wang, Jingjun
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (19): : 132 - 135
  • [6] Induction Motor Fault Diagnosis Based on Zero-Sequence Current Analysis
    Duda, Arkadiusz
    Drozdowski, Piotr
    ENERGIES, 2020, 13 (24)
  • [7] A Principle of Fault Line Selection Based on Increasing Zero-sequence Current in Non-ground Neutral System
    Huang, Tantan
    Zhang, Huifen
    Gao, Zhipeng
    Guo, Yao
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 2052 - 2056
  • [8] Study on a new filter to suppress the zero-sequence current
    Li, Yang-Chun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (07): : 91 - 93
  • [9] Fault detection method for unbalanced distribution networks based on flexible regulation of zero-sequence voltage
    Zhang W.
    Wang L.
    Xue Y.
    Xu B.
    Wang C.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (11): : 159 - 169
  • [10] Zero-Sequence Circulating Current Reduction Method for Parallel HEPWM Inverters Between AC Bus and DC Bus
    Chen, Tsung-Po
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (01) : 290 - 300