PIXE analysis is very useful for the simultaneous determination of various elements. Typically, when micro-PIXE analysis of biological samples with high water content is performed in a vacuum, freeze-drying methods are used to fix the structure and remove any ice crystals present in a controlled manner to prevent changes or redistribution of elemental content in the sample. This method is essential for cell size analysis. However, we considered that fixation is not always necessary for macroscopic analysis of plant tissue size. Therefore, we investigated the extent to which elemental density changes with vacuum extraction from elemental density ratios obtained from micro-PIXE analysis of Arabidopsis thaliana leaves in-air and in-vacuum. The deformation caused by beam irradiation and the quantitative changes of C, O, and H in the samples were also evaluated by STIM and RBS analyses of Arabidopsis thaliana petal.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] PIXE and micro-PIXE studies of ion release around endosseous implants in animals
    INFN, Legnaro, Italy
    Nucl Instrum Methods Phys Res Sect B, (289-293):
  • [42] PIXE and micro-PIXE studies of ion release around endosseous implants in animals
    Egeni, GP
    Jaksic, M
    Moschini, G
    Passi, P
    Piattelli, A
    Rossi, P
    Rudello, V
    Tauro, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 109 : 289 - 293
  • [43] EXPERIMENTAL COMPARISON OF MICRO-PIXE WITH OTHER METHODS UTILIZED FOR BIOMINERALIZATION STUDIES
    CICHOCKI, T
    HECK, D
    JARCZYK, L
    ROKITA, E
    STRZALKOWSKI, A
    SYCH, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 31 (03): : 449 - 455
  • [44] Micro-PIXE mapping of sodium and chlorine in selected seagrasses
    Przybylowicz, WJ
    Pineda, CA
    Barnabas, AD
    Mesjasz-Przybylowicz, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 150 (1-4): : 282 - 290
  • [45] Micro-PIXE studies on gallium incorporation in mineralized tissue
    Rokita, E
    Korbas, M
    Mutsaers, PHA
    Taton, G
    de Voigt, MJA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 529 - 532
  • [46] Lapis lazuli provenance study by means of micro-PIXE
    Re, Alessandro
    Lo Giudice, Alessandro
    Angelici, Debora
    Calusi, Silvia
    Giuntini, Lorenzo
    Massi, Mirko
    Pratesi, Giovanni
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (20): : 2373 - 2377
  • [47] Preliminary studies on applications of micro-PIXE to atmospheric aerosols
    Kasahara, M
    Ma, CJ
    Kamiya, T
    Sakai, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 622 - 627
  • [48] Elemental imaging of rat epididymis by micro-PIXE analysis
    Homma-Takeda, S
    Nishimura, Y
    Watanabe, Y
    Imaseki, H
    Yukawa, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 210 : 368 - 372
  • [49] Micro-PIXE studies of char populations in northern Canada
    Campbell, J.L.
    Babaluk, J.A.
    Halden, N.M.
    Kristofferson, A.H.
    Maxwell, J.A.
    Mejia, S.R.
    Reist, J.D.
    Teesdale, W.J.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1999, 150 (1-4): : 260 - 266
  • [50] MICRO-PIXE ANALYSIS OF SILICATE REFERENCE-STANDARDS
    CZAMANSKE, GK
    SISSON, TW
    CAMPBELL, JL
    TEESDALE, WJ
    AMERICAN MINERALOGIST, 1993, 78 (9-10) : 893 - 903