Enhancement in performance of parabolic trough collector with serrated twisted-tape inserts

被引:0
|
作者
Rawani A. [1 ]
Sharma S.P. [1 ]
Singh K.D.P. [1 ]
机构
[1] Department of Mechanical Engineering, National Institute of Technology, Jamshedpur, Jharkhand
来源
Int. J. Thermodyn. | / 2卷 / 111-119期
关键词
Collector efficiency factor; Collector heat removal factor; Efficiency; Useful heat gain;
D O I
10.5541/ijot.5000210005
中图分类号
学科分类号
摘要
The aim of this study is to analytically investigate the performance of parabolic trough collector (PTC) with serrated twisted tape insert in the absorber tube. The heat transfer equations for fully developed flow under quasi-steady state conditions have been developed in order to analyze entropy generation, exergy efficiency, thermal efficiency, rise in fluid temperature and to study the effect of system and operating parameters on performance. A computer program, based on mathematical models is developed in C++ language to estimate the temperature rise of fluid for evaluation of performances under specified conditions. For numerical simulations four different twist ratio, x = 1,2,3,4 and mass flow rate 0.06 kg/s to 0.16 kg/s (3000≤Re≤9000) are used. This study shows that twisted tape insert when used shows great promise for enhancing the performance of PTC. Results show that for x=1, Nusselt number/heat transfer coefficient is found to be 4.38 and 3.51 times over plain absorber of PTC at mass flow rate of 0.06 kg/s and 0.16 kg/s respectively; while corresponding enhancement in thermal efficiency is 15.7% and 5.41% respectively. Also the exergy efficiency has been found to be 12.10% and 12.62% and enhancement factor is 1.157 and 1.053 for same set of conditions.
引用
收藏
页码:111 / 119
页数:8
相关论文
共 50 条
  • [41] Experimental study of the effect of twisted-tape inserts on flow boiling heat transfer enhancement and pressure drop penalty
    Mogaji, Taye Stephen
    Kanizawa, Fabio Toshio
    Bandarra Filho, Enio Pedone
    Ribatski, Gherhardt
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (02): : 504 - 515
  • [42] Hydrothermal effects of using two twisted tape inserts in a parabolic trough solar collector filled with MgO-MWCNT/thermal oil hybrid nanofluid
    Alnaqi, Abdulwahab A.
    Alsarraf, Jalal
    Al-Rashed, Abdullah A. A. A.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 47
  • [43] Performance prediction of extended surface absorber solar air collector with twisted tape inserts
    Kumar, Rajesh
    Chand, Prabha
    SOLAR ENERGY, 2018, 169 : 40 - 48
  • [44] Turbulent Flow in Circular Tubes with Twisted-Tape Inserts and Axial Interrupted Ribs
    Zhang, Y. M.
    Han, J. C.
    Lee, C. P.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2017, 24 (1-6) : 243 - 254
  • [45] Chaotic mixing characteristics in static mixers with different axial twisted-tape inserts
    Meng, Huibo
    Song, Mingyuan
    Yu, Yanfang
    Wang, Feng
    Wu, Jianhua
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2015, 93 (10): : 1849 - 1859
  • [46] Heat transfer by laminar flow in a vertical and horizontal pipe with twisted-tape inserts
    A. Klaczak
    Heat and Mass Transfer, 2001, 37 : 443 - 448
  • [47] Pool boiling heat transfer enhancement by twisted-tape fins
    Ebrahimi-Dehshali, Massoud
    Najm-Barzanji, Seyyed Zagros
    Hakkaki-Fard, Ali
    APPLIED THERMAL ENGINEERING, 2018, 135 : 170 - 177
  • [48] Thermal performance enhancement of a novel receiver for parabolic trough solar collector
    Justin Byiringiro
    Meriem Chaanaoui
    Belkheir Hammouti
    Byiringiro, Justin (j.byiringiro@ueuromed.org), 2025, 246 (01)
  • [49] Heat transfer enhancement by tapered twisted tape inserts
    Piriyarungrod, N.
    Eiamsa-ard, S.
    Thianpong, C.
    Pimsarn, M.
    Nanan, K.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2015, 96 : 62 - 71
  • [50] SATURATED FORCED-CONVECTIVE BOILING HEAT-TRANSFER WITH TWISTED-TAPE INSERTS
    JENSEN, MK
    BENSLER, HP
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1986, 108 (01): : 93 - 99