Testing the accuracy of low-beam-energy electron-excited X-ray microanalysis with energy-dispersive spectrometry

被引:0
|
作者
Newbury, Dale E. [1 ]
Ritchie, Nicholas W. M. [1 ]
机构
[1] National Institute of Standards and Technology, Gaithersburg,MD,20899-8370, United States
关键词
Indium phosphide - Nickel alloys - Nickel compounds - Vanadium pentoxide;
D O I
10.1007/s10853-024-10285-4
中图分类号
学科分类号
摘要
The accuracy of electron-excited X-ray microanalysis with energy-dispersive spectrometry (EDS) has been tested in the low beam energy range, specifically at an incident beam energy of 5 keV, which is the lowest beam energy for which a useful characteristic X-ray peak can be excited for all elements of the periodic table, excepting H and He. Elemental analysis results are reported for certified reference materials (CRM), stoichiometric compounds, minerals, and metal alloys of independently known or measured composition which had microscopic homogeneity suitable for microanalysis. Two-hundred sixty-three concentration measurements for 39 elements in 113 materials were determined following the k-ratio protocol and using the EDS analytical software NIST DTSA-II. The accuracy of the results, as characterized by the relative deviation from expected value (RDEV) metric, was such that more than 98% of the results were found to be captured within a range of ±5% RDEV, while 82% of the results fell in the range -2% to 2% RDEV. © This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply 2024.
引用
收藏
页码:19088 / 19111
相关论文
共 50 条
  • [31] Energy-dispersive X-ray diffraction using an annular beam
    Dicken, A. J.
    Evans, J. P. O.
    Rogers, K. D.
    Greenwood, C.
    Godber, S. X.
    Prokopiou, D.
    Stone, N.
    Clement, J. G.
    Lyburn, I.
    Martin, R. M.
    Zioupos, P.
    [J]. OPTICS EXPRESS, 2015, 23 (10): : 13443 - 13454
  • [32] LOCAL RESOLUBILITY IN ENERGY-DISPERSIVE ELECTRON-BEAM MICROANALYSIS
    DUDEK, HJ
    ZIEGLER, G
    [J]. MIKROSKOPIE, 1976, 32 (5-6) : 184 - 184
  • [33] Energy-Dispersive X-ray Spectrometry Performance on Multiple Transmission Electron Microscope Platforms
    Demarest, James
    Deeb, Chris
    Murray, Thomas
    Zhai, Hong-Ying
    [J]. ISTFA 2010: CONFERENCE PROCEEDINGS FROM THE 36TH INTERNATIONAL SYMPOSIUM FOR TESTING AND FAILURE ANALYSIS, 2010, : 301 - 303
  • [34] Energy-dispersive vs wavelength-dispersive X-ray fluorescence spectrometry
    Brill, M
    [J]. METALL, 1996, 50 (7-8): : 504 - 511
  • [35] Low-Voltage Scanning Electron Microscopy and Energy-Dispersive X-Ray Microanalysis of the Interface of Multilayer Polymer Composite
    Orekhov, A. S.
    Arkharova, N. A.
    Kononova, S. V.
    Klechkovskaya, V. V.
    [J]. CRYSTALLOGRAPHY REPORTS, 2018, 63 (05) : 745 - 748
  • [36] High-resolution, energy-dispersive microcalorimeter spectrometer for X-ray microanalysis
    Wollman, DA
    Irwin, KD
    Hilton, GC
    Dulcie, LL
    Newbury, DE
    Martinis, JM
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1997, 188 : 196 - 223
  • [37] Low-Voltage Scanning Electron Microscopy and Energy-Dispersive X-Ray Microanalysis of the Interface of Multilayer Polymer Composite
    A. S. Orekhov
    N. A. Arkharova
    S. V. Kononova
    V. V. Klechkovskaya
    [J]. Crystallography Reports, 2018, 63 : 745 - 748
  • [38] The transistor and energy-dispersive x-ray spectrometry: roots and milestones in x-ray analysis
    Ryon, RW
    [J]. X-RAY SPECTROMETRY, 2001, 30 (06) : 361 - 372
  • [39] USE OF SENSITIVITY AS A FUNCTION OF FLUORESCENT X-RAY-ENERGY IN ENERGY-DISPERSIVE X-RAY SPECTROMETRY
    WEGSCHEIDER, W
    ELLIS, AT
    GOLDBACH, K
    LEYDEN, DE
    MAHAN, KI
    [J]. ANALYTICA CHIMICA ACTA, 1986, 188 : 59 - 66
  • [40] REDUCTION OF BACKGROUND DUE TO BACKSCATTERED ELECTRONS IN ENERGY-DISPERSIVE X-RAY MICROANALYSIS
    HALL, TA
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1977, 110 (JUL): : 103 - 106