Online monitoring the discharging products of SF6 with photoelectron ionization mass spectrometry

被引:0
|
作者
Tang, Bin [1 ]
Zhao, Wu-Duo [2 ]
Zhu, Li-Ping [1 ]
Hou, Ke-Yong [2 ]
Huang, Yun-Guang [1 ]
Li, Hai-Yang [2 ]
机构
[1] Electric Power Research Institute, Guangxi Power Grid Corporation, Nanning,530023, China
[2] Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian,116023, China
关键词
Gas chromatography - SF6 insulation - Electric circuit breakers - Electric substations - Electric switchgear - Partial discharges - Photoelectrons - Gases - Ionization of gases - Mass spectrometry - Byproducts - Gas plants - HVDC power transmission - Infrared spectroscopy - Photons;
D O I
10.7538/zpxb.2015.36.05.0454
中图分类号
学科分类号
摘要
Sulfur hexafluoride (SF6) is a gas used in electrical substations at electric power plants as an insulator in circuit breakers and switchgear. SF6 gas can generate a variety of decomposed products due to discharge or overheat inside the high-voltage devices. The discharging fault inside of the electric device insulated by SF6 is closely related to the composition and content of SF6 gas discharge products. Some of the byproducts are active and unstable, which create difficulties on testing them and have to be analyzed through a variety of testing methods. Gas chromatography, gas chromatography-mass spectrometry and infrared spectrometry have been developed to rapidly analyze the discharge products, but these methods are time-consuming and very hard to realize the in situ analysis and on-line diagnostics. An online monitoring system for discharging products of SF6 with photoelectron ionization (PEI) time-of-flight mass spectrometry was developed in this paper. It can be used for diagnosis of discharging fault inside of the electric device by real-time monitoring for discharging products of SF6. The mass spectrum of SF6 gas discharge products and the kinetics were investigated using a gas discharging study with home-made low direct current voltage system. The main byproducts of SO2F2, SOF2, SO2 and SF4 can be clearly detected. This method is expected to provide the power production field with online mass spectrometry monitoring and track the fault inside of the SF6 electrical equipment on its running condition. ©, 2015, Chinese Society for Mass Spectrometry. All right reserved.
引用
下载
收藏
页码:454 / 459
相关论文
共 50 条
  • [21] MASS-SPECTROMETRY OF ARCS IN SF6 CIRCUIT-BREAKERS
    RUEGSEGGER, W
    MEIER, R
    KNEUBUHL, FK
    SCOTZAU, HJ
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1985, 37 (03): : 115 - 135
  • [22] Threshold ionization mass spectrometry measurements of neutral density in dual frequency SF6/O2 plasmas
    Jaiprakash, VC
    Thompson, BE
    PLASMA PROCESSING XII, 1998, 98 (04): : 101 - 113
  • [23] MEASUREMENT OF IONIZATION AND ATTACHMENT COEFFICIENTS IN SF6
    BOYD, HA
    CRICHTON, GC
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1971, 118 (12): : 1872 - &
  • [24] Online detection technology for SF6 decomposition products in electrical equipment: a review
    Fan, Xiaopeng
    Li, Li
    Zhou, Yongyan
    Tang, Nian
    Zou, Zhuanglei
    Li, Xiaodian
    Huang, Guojun
    Liu, Mingzheng
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (06) : 707 - 711
  • [25] SPARKING POTENTIALS AND IONIZATION COEFFICIENTS IN SF6
    MALLER, VN
    NAIDU, MS
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1976, 123 (01): : 107 - 108
  • [26] INTERACTIONS OF ELECTRONS WITH SF6 - IONIZATION AND ATTACHMENT
    MARK, TD
    STAMATOVIC, A
    SCHEIER, P
    ZEITSCHRIFT FUR PHYSIK D-ATOMS MOLECULES AND CLUSTERS, 1989, 12 (1-4): : 303 - 305
  • [27] Design of Online Condition Monitoring Hardware device for SF6 Circuit Breaker
    Mallikar-Godbole, Lubdha
    Kushare, B. E.
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND CONTROL (ISCO'16), 2016,
  • [28] Influence of SF6 Concentration in SF6/N2 Gas Mixture on Decomposition Products Analysis Based on Photoacoustic Spectrometry Detection
    Li K.
    Ma F.
    Zhu H.
    Zhu F.
    Han D.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (17): : 3773 - 3780
  • [29] MASS-SPECTROMETRY OF HIGH-PRESSURE ARCS IN AIR AND SF6
    RUEGSEGGER, W
    KNEUBUHL, FK
    SCHOTZAU, HJ
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1983, 31 (01): : 9 - 13
  • [30] IONIZATION AND ATTACHMENT COEFFICIENTS MEASURED IN SF6/AR AND SF6/KR GAS-MIXTURES
    QIU, Y
    XIAO, DM
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1994, 27 (12) : 2663 - 2665