Experimental study on fire extinguishing efficiency of polymer hydrogel fire extinguishing agent in pine-fir mixed coniferous forest fires

被引:1
|
作者
Dai, Zhangyin [1 ]
Huang, Congbao [1 ]
Chen, Youcheng [1 ]
Zhong, Manyin [1 ]
He, Wenwu [1 ]
机构
[1] Guizhou Univ, Sch Min, Guiyang 550025, Guizhou, Peoples R China
关键词
Pine and fir; Wood stack fires; Leaf litter fires; Polymeric hydrogel; Extinguishing supply strength; Suppression effects; COMPONENTS;
D O I
10.1016/j.csite.2024.105413
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pine and fir wood is commonly used in furniture, gardening and construction industries, and has high economic value. It is in great demand in the timber industry. Therefore, pine and fir trees are now widely planted in China. However, pine and fir trees belong to flammable species, with a high content of oil and grease, and the ignition point of pine and fir leaf litter is extremely low. Once burning occurs, it spreads rapidly and can easily turn into a major forest fire. Therefore, the use of extinguishing agents to mitigate and prevent the spread of forest fires is of great importance. In this paper, fire and extinguishing tests were investigated using mixed wood stack burning of pine and fir and mixed fuel from leaf litter. The suppression effects of three different extinguishing agents, AFFF, CAF and hydrogel, on wood fires and leaf litter combustion were compared. And the suppression supply strength of different extinguishing agents to suppress pine and fir trees was determined. The results show that both hydrogel and CAF can effectively extinguish wood stack fires, and AFFF shows re-ignition phenomenon after extinguishing wood stack fires; Comparison of extinguishing time, cooling rate and heat dissipation capacity revealed that hydrogel was superior to CAF; Hydrogel has a highly efficient fire extinguishing properties. It is calculated that the amount of hydrogel used to extinguish pine and cedar fires is only 54 % of the water required, about 87 % of the amount of Class A foam required under the same circumstances, and about 79 % of the amount of aqueous film-forming foam required; Compared with the foam extinguishing agent, the hydrogel extinguishing agent showed better cooling effect, less extinguishing agent dosage, and shorter extinguishing time of 11 s when extinguishing fires in leaf litter; For the rapid spread of leaf litter combustion and easy to re-ignite characteristics, hydrogel has a significant anti-reignition effect.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Experimental study on the effectiveness of dry water material to suppress oil pool fire and analysis of fire extinguishing mechanism
    Wu, Zhenkun
    Chai, Guoqiang
    Zhu, Guoqing
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (18) : 10193 - 10212
  • [42] Study on the fire extinguishing efficiency and mechanism of composite superfine dry powder containing ferrocene
    Yan, Chenlu
    Pan, Xuhai
    Hua, Min
    Li, Shunchao
    Guo, Xinxin
    Zhang, Chendong
    FIRE SAFETY JOURNAL, 2022, 130
  • [43] Experimental study on preparation of a new cleaner water-based powder agent and its extinguishing efficiency and thermodynamic mechanism on a typical fuel fire
    Chai, Guoqiang
    Xie, Ying
    Wang, Yang
    Zhu, Guoqing
    Markert, Frank
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (12) : 6483 - 6501
  • [44] Experimental Study on Total Flooding Extinguishing Test by New Ultra-fine Water Mist Fire Extinguisher Extinguishing Combustion of Paper
    Zhu, De-ming
    Liu, Jian-yong
    Yu, Yuan
    Liang, Dong
    2014 7TH INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION (ICICTA), 2014, : 252 - 255
  • [45] Research on the Fire Extinguishing Efficiency of Low-Pressure Water Mist in Urban Underground Utility Tunnel Cable Fires
    Jia, Boyan
    Xia, Yanwei
    Ning, Zhaoyu
    Li, Bin
    Zhang, Guowei
    Zhang, Zhiwei
    FIRE-SWITZERLAND, 2023, 6 (11):
  • [46] Numerical Simulation and Experimental Study of Gas-Solid Two-Phase Spraying of Dry Powder Fire-Extinguishing System Based on Fire-Extinguishing Inspection Robot
    Chu, Shengli
    Chen, Tao
    Gan, Yifan
    Liu, Yixin
    Zheng, Wenpei
    Tang, Yan
    Zhou, Wendong
    PROCESSES, 2024, 12 (06)
  • [47] Research on the influence of wollastonite fibers on the stability of foam extinguishment agent and its effect on the extinguishing efficiency of pool fire
    Li, Xiujuan
    Guo, Ruisong
    Qian, Xiaodong
    FIRE AND MATERIALS, 2020, 44 (08) : 1053 - 1063
  • [49] Experimental study on fire extinguishing of water mist with a newly prepared multi-component additive
    Wu, Binbin
    Liao, Guangxuan
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 317 - 323
  • [50] Experimental study on fire extinguishing with a newly prepared multi-component compressed air foam
    WANG XiShi LIAO YaoJian LIN Lin State Key Laboratory of Fire Science University of Science and Technology of China Hefei China
    Chinese Science Bulletin, 2009, 54 (03) : 492 - 496