Experimental study on fire extinguishing efficiency of polymer hydrogel fire extinguishing agent in pine-fir mixed coniferous forest fires

被引:1
|
作者
Dai, Zhangyin [1 ]
Huang, Congbao [1 ]
Chen, Youcheng [1 ]
Zhong, Manyin [1 ]
He, Wenwu [1 ]
机构
[1] Guizhou Univ, Sch Min, Guiyang 550025, Guizhou, Peoples R China
关键词
Pine and fir; Wood stack fires; Leaf litter fires; Polymeric hydrogel; Extinguishing supply strength; Suppression effects; COMPONENTS;
D O I
10.1016/j.csite.2024.105413
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pine and fir wood is commonly used in furniture, gardening and construction industries, and has high economic value. It is in great demand in the timber industry. Therefore, pine and fir trees are now widely planted in China. However, pine and fir trees belong to flammable species, with a high content of oil and grease, and the ignition point of pine and fir leaf litter is extremely low. Once burning occurs, it spreads rapidly and can easily turn into a major forest fire. Therefore, the use of extinguishing agents to mitigate and prevent the spread of forest fires is of great importance. In this paper, fire and extinguishing tests were investigated using mixed wood stack burning of pine and fir and mixed fuel from leaf litter. The suppression effects of three different extinguishing agents, AFFF, CAF and hydrogel, on wood fires and leaf litter combustion were compared. And the suppression supply strength of different extinguishing agents to suppress pine and fir trees was determined. The results show that both hydrogel and CAF can effectively extinguish wood stack fires, and AFFF shows re-ignition phenomenon after extinguishing wood stack fires; Comparison of extinguishing time, cooling rate and heat dissipation capacity revealed that hydrogel was superior to CAF; Hydrogel has a highly efficient fire extinguishing properties. It is calculated that the amount of hydrogel used to extinguish pine and cedar fires is only 54 % of the water required, about 87 % of the amount of Class A foam required under the same circumstances, and about 79 % of the amount of aqueous film-forming foam required; Compared with the foam extinguishing agent, the hydrogel extinguishing agent showed better cooling effect, less extinguishing agent dosage, and shorter extinguishing time of 11 s when extinguishing fires in leaf litter; For the rapid spread of leaf litter combustion and easy to re-ignite characteristics, hydrogel has a significant anti-reignition effect.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Experimental study on fire extinguishing characteristics of Automatic sprinkler system
    Wu, Fan
    Cui, Yongyi
    Qu, Fang
    Mai, Lei
    PROCEEDINGS 2015 SIXTH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND ENGINEERING APPLICATIONS ISDEA 2015, 2015, : 389 - 392
  • [22] Influence of the Method of Water Supply to the Zone of a Forest Fire on the Efficiency of its Extinguishing
    G. V. Kuznetsov
    A. O. Zhdanova
    P. A. Strizhak
    Yu. K. Atroshenko
    Journal of Engineering Physics and Thermophysics, 2020, 93 : 1460 - 1469
  • [23] INFLUENCE OF THE METHOD OF WATER SUPPLY TO THE ZONE OF A FOREST FIRE ON THE EFFICIENCY OF ITS EXTINGUISHING
    Kuznetsov, G. V.
    Zhdanova, A. O.
    Strizhak, P. A.
    Atroshenko, Yu. K.
    JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2020, 93 (06) : 1460 - 1469
  • [24] Fire extinguishing efficiency of hydrocarbon and fluorinated film-forming foaming agent
    Vlasov, Nikolay
    Melnikov, Artem
    INTERNATIONAL SCIENCE CONFERENCE SPBWOSCE-2018: BUSINESS TECHNOLOGIES FOR SUSTAINABLE URBAN DEVELOPMENT, 2019, 110
  • [25] Study on water-based fire extinguishing agent formulations and properties
    Huang Yinsheng
    Zhang Wencheng
    Dai Xiaojing
    Zhao Yu
    2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 : 649 - 654
  • [26] Study on gel extinguishing agent and its application in fire fighting technology
    Chen, N
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 1036 - 1041
  • [27] An experimental study on the performance of fire extinguishing system according to the agent charging condition and nozzle type
    Kim, Junsung
    Ahn, Cheolhee
    Ahn, Hyeongjin
    Park, Jiwon
    Park, Warngyu
    Cheong, Cheolung
    Choi, Gyungmin
    Park, Yeseul
    HELIYON, 2023, 9 (09)
  • [28] Study of the Aging Impact on the Extinction Efficiency of an Extinguishing Powder for Sodium Fire
    Kusumanindyah, Nur
    Brissonneau, Laurent
    Gilardi, Thierry
    Gatumel, Cendrine
    Berthiaux, Henri
    15TH INTERNATIONAL SYMPOSIUM ON LOSS PREVENTION AND SAFETY PROMOTION (LOSS 2016), 2016, 48 : 367 - 372
  • [29] Enhancing extinguishing efficiency for lithium-ion battery fire: Investigating the extinguishing mechanism and surface/interfacial activity of F-500 microcapsule extinguishing agent
    Meng, Xiangdong
    Wang, Zhandong
    Liu, Bingzhi
    Gao, Yongxiang
    Zhang, Jinyang
    Sun, Jinhua
    Wang, Qingsong
    ETRANSPORTATION, 2024, 22
  • [30] Experimental study on the synergistic effect of fire extinguishing by water and potassium salts
    Zhang Tianwei
    Liu Hao
    Zhiyue Han
    Wang Yong
    Guo Zidong
    Wang Chaoqing
    Journal of Thermal Analysis and Calorimetry, 2019, 138 : 857 - 867