Long-optical-path scanning mechanism for optical coherence tomography

被引:0
|
作者
Shiina, Tatsuo [1 ]
Moritani, Yohei [1 ]
Ito, Masafumi [1 ]
Okamura, Yasuyuki [1 ]
机构
[1] Faculty of Systems Engineering, Wakayama University, 930 Sakaedani, Wakayama-shi, Wakayama 640-8510, Japan
来源
Applied Optics | 2003年 / 42卷 / 19期
关键词
Amplifiers (electronic) - Coherent light - Rotating disks - Scanning - Tomography;
D O I
暂无
中图分类号
学科分类号
摘要
A new scanning mechanism for changing long optical paths is proposed. This mechanism consists of corner reflectors arranged equally upon a disk and an outer mirror. Rotating the 120-mmφdisk cases a long-optical-path change in each reflector with a near linearity of more than 40 mm. An optical coherence tomography system is described that confirms the usefulness of the proposed mechanism. Its operating characteristics and accuracy are evaluated by analysis and experiment. The deviation of the optical-path change is less than 1.52% at a reflector rotation angle of ±10°. A high-speed lock-in amplifier is utilized for fundamental measurements of glass samples. © 2003 Optical Society of America.
引用
收藏
页码:3795 / 3799
相关论文
共 50 条
  • [31] Chinese vinegar classification via volatiles using long-optical-path infrared spectroscopy and chemometrics
    Dong, D.
    Zheng, W.
    Jiao, L.
    Lang, Y.
    Zhao, X.
    FOOD CHEMISTRY, 2016, 194 : 95 - 100
  • [32] Long-optical-path thin-layer spectroelectrochemical flow cell with inexpensive gold electrodes
    Daniel, D
    Gutz, IGR
    ELECTROANALYSIS, 2001, 13 (8-9) : 681 - 685
  • [33] Optical Coherence Tomography and Optical Coherence Tomography Angiography in Neglected Diseases
    Mahendradas, Padmamalini
    Acharya, Isha
    Rana, Vipin
    Bansal, Reema
    Ben Amor, Hager
    Khairallah, Moncef
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2024, 32 (07) : 1427 - 1434
  • [34] Optical coherence tomography and Doppler optical coherence tomography in the gastrointestinal tract
    Osiac, Eugen
    Saftoiu, Adrian
    Gheonea, Dan Ionut
    Mandrila, Ion
    Angelescu, Radu
    WORLD JOURNAL OF GASTROENTEROLOGY, 2011, 17 (01) : 15 - 20
  • [35] Optical coherence tomography and optical coherence tomography angiography in multiple sclerosis
    Gad A.H.E.
    Abd El Hamid N.A.
    El-Mofty R.M.A.-M.
    El Ghoneimy L.A.T.
    The Egyptian Journal of Neurology, Psychiatry and Neurosurgery, 59 (1)
  • [36] Optical coherence tomography and Doppler optical coherence tomography in the gastrointestinal tract
    Eugen Osiac
    Adrian Sǎftoiu
    Dan Ionut Gheonea
    Ion Mandrila
    Radu Angelescu
    World Journal of Gastroenterology, 2011, 17 (01) : 15 - 20
  • [37] Optical coherence tomography and optical coherence tomography angiography in uveitis: A review
    Invernizzi, Alessandro
    Cozzi, Mariano
    Staurenghi, Giovanni
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 (03): : 357 - 371
  • [38] Optical Coherence Tomography and Optical Coherence Tomography with Angiography in Multiple Sclerosis
    Chalkias, Ioannis-Nikolaos
    Bakirtzis, Christos
    Pirounides, Demetrios
    Boziki, Marina Kleopatra
    Grigoriadis, Nikolaos
    HEALTHCARE, 2022, 10 (08)
  • [39] Ultrahigh scanning speed optical coherence tomography using optical frequency comb generators
    Lee, SJ
    Widiyatmoko, B
    Kourogi, M
    Ohtsu, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2001, 40 (8B): : L878 - L880
  • [40] Double common-path interferometer for flexible optical probe of optical coherence tomography
    Park, Jae Seok
    Chen, Zhongping
    Jeong, Myung Yung
    Kim, Chang-Seok
    OPTICS EXPRESS, 2012, 20 (02): : 1102 - 1112