Decrease on temperature rise of ball screw by water cooling of the nut from outside

被引:0
|
作者
Nozaki T.
Otsuka J.
Toake Y.
Nakata A.
Yukihira K.-I.
Shirai K.
Nishide T.
机构
来源
| 1600年 / Japan Society for Precision Engineering卷 / 83期
关键词
Ball screw; Precision positioning; Temperature rise and water cooling;
D O I
10.2493/jjspe.83.89
中图分类号
学科分类号
摘要
In regard with the precision positioning devices using the ball screw, its temperature rises during operation and this causes positioning error. In this paper, a ball screw temperature is decreased by cooling the nut from outside using two kinds of water jackets. This method is effective and very cheap. In case of the first jacket (D type), the water circulates along the double spiral grooves while in case of the second jacket (G type), cooling water moves going and returning inside the flow path along the longitudinal direction and the water circulates in the holes. By these two kind of jackets, the nut is cooled and at the same time the ball screw is cooled indirectly. The temperature of the ball screw and nut are measured by surface temperature measuring instrument and thermocouples. As a result, the followings are clarified. (1) D type is more effective than G type. (2) The ball screw temperature can be estimated by measuring the nut surface temperature.
引用
收藏
页码:89 / 93
页数:4
相关论文
共 50 条
  • [31] Prediction of Temperature Rise in Water-Cooling DC Busbar Through Coupled Force and Natural Convection Thermal-Fluid Analysis
    Guo, Bin
    Song, Zhiquan
    Fu, Peng
    Jiang, Li
    Wang, Min
    Dong, Ling
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (12) : 3346 - 3352
  • [32] Water temperature regimen analysis of intensive fishfarms associated with cooling effluents from power plants
    Gutierrez-Estrada, J. C.
    Pulido-Calvo, I.
    BIOSYSTEMS ENGINEERING, 2007, 96 (04) : 581 - 591
  • [33] Author Correction: Change in cooling degree days with global mean temperature rise increasing from 1.5 °C to 2.0 °C
    Nicole D. Miranda
    Jesus Lizana
    Sarah N. Sparrow
    Miriam Zachau-Walker
    Peter A. G. Watson
    David C. H. Wallom
    Radhika Khosla
    Malcolm McCulloch
    Nature Sustainability, 2023, 6 : 1716 - 1716
  • [34] Development of a system based on water atomization to decrease, prior to treatment, the temperature of the gas emitted from aluminium cells
    Bonnier, M.
    Massambi, S.
    Jolas, J-M.
    Girault, G.
    Demetriou, V.
    Wheaton, D.
    LIGHT METALS 2007, 2007, : 193 - +
  • [35] EVIDENCE FROM STATISTICAL MATERIAL OF AN ARTIFICIAL TEMPERATURE INCREASE IN STECHLINSEE AS A RESULT OF COOLING-WATER INFLOW
    NEUBERT, W
    ZEITSCHRIFT FUR METEOROLOGIE, 1978, 28 (03): : 170 - 173
  • [36] A novel high-temperature water cooling system utilizing cascaded cold energy from underground water plants in northern China
    Tai, Chuanmin
    Zhang, Yunqing
    Liu, Zhanli
    Ji, Xingliang
    Lei, Wenjun
    Tian, Guansan
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 64
  • [37] Evaluating building stones: Physical-mechanical changes from high-temperature fire and water cooling
    Pires, Vera
    Sitzia, Fabio
    Lisci, Carla
    Cordeiro, Licinio
    HELIYON, 2024, 10 (16)
  • [38] Numerical Simulation of Coolant Temperature Rise by Copper Metal foam Insert in Water-cooled Air-Kerosene Combustion Gas Heated Cooling Channel
    Rose, J. B. Ralphin
    George, S. K.
    Rashid, K.
    JOURNAL OF APPLIED FLUID MECHANICS, 2016, 9 (06) : 3033 - 3043
  • [39] Thermal effluent from the power sector: an analysis of once-through cooling system impacts on surface water temperature
    Madden, N.
    Lewis, A.
    Davis, M.
    ENVIRONMENTAL RESEARCH LETTERS, 2013, 8 (03):
  • [40] Failure Analysis of a Low-Temperature Carbon Steel Pipe from a Nuclear Power Station Cooling Water System
    Ruminski A.