Decrease on temperature rise of ball screw by water cooling of the nut from outside

被引:0
|
作者
Nozaki T.
Otsuka J.
Toake Y.
Nakata A.
Yukihira K.-I.
Shirai K.
Nishide T.
机构
来源
| 1600年 / Japan Society for Precision Engineering卷 / 83期
关键词
Ball screw; Precision positioning; Temperature rise and water cooling;
D O I
10.2493/jjspe.83.89
中图分类号
学科分类号
摘要
In regard with the precision positioning devices using the ball screw, its temperature rises during operation and this causes positioning error. In this paper, a ball screw temperature is decreased by cooling the nut from outside using two kinds of water jackets. This method is effective and very cheap. In case of the first jacket (D type), the water circulates along the double spiral grooves while in case of the second jacket (G type), cooling water moves going and returning inside the flow path along the longitudinal direction and the water circulates in the holes. By these two kind of jackets, the nut is cooled and at the same time the ball screw is cooled indirectly. The temperature of the ball screw and nut are measured by surface temperature measuring instrument and thermocouples. As a result, the followings are clarified. (1) D type is more effective than G type. (2) The ball screw temperature can be estimated by measuring the nut surface temperature.
引用
收藏
页码:89 / 93
页数:4
相关论文
共 50 条
  • [11] Study on thermal behavior analysis of nut/shaft air cooling ball screw for high-precision feed drive
    Xu, Zhe-Zhu
    Liu, Xiao-Jing
    Lyu, Sung-Ki
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (01) : 123 - 128
  • [12] UTILIZATION OF WASTE HEAT FOR THE TEMPERATURE RISE OF THE WORT COOLING WATER
    SCHWARZ, K
    LEBENSMITTELINDUSTRIE, 1985, 32 (05): : 218 - &
  • [13] Cooling effect and temperature regulation of oil cooling system for ball screw feed drive system of precision machine tool
    Shi, Hu
    He, Bin
    Yue, Yinyun
    Min, Chaoqing
    Mei, Xuesong
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [15] Generator temperature rise calculation with direct water cooling in the stator winding
    Kalmykov, I.
    García, A.
    Borgna, H.
    International Journal on Hydropower and Dams, 2001, 8 (03): : 92 - 95
  • [16] Absorption cooling sources atmospheric emissions decrease by implementation of simple algorithm for limiting temperature of cooling water
    Wojdyga, Krzysztof
    Malicki, Marcin
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY SYSTEMS AND ENVIRONMENTAL ENGINEERING (ASEE17), 2017, 22
  • [17] EXPERIMENTAL STUDY OF INFLUENCE ON TEMPERATURE RISE DUE TO RETRACTION OF WATER INTAKE IN COOLING WATER ENGINEERING
    Tian, Chun
    Cheng, Qiang
    Hao, Ruixia
    ADVANCES IN WATER RESOURCES AND HYDRAULIC ENGINEERING, VOLS 1-6, 2009, : 1235 - 1239
  • [18] Research on the effects of cooling water velocity on temperature rise of the water-cooled motor in electric vehicles
    Li, Cui-Ping
    Chai, Feng
    Cheng, Shu-Kang
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2012, 16 (09): : 1 - 8
  • [19] Analysis of Screw Chiller's Refrigeration Performance under Large Temperature Difference Cooling-Water
    Chen, Gang
    Cheng, Xin
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 2319 - 2322
  • [20] Optimisation of Cooling-Water Systems Considering Temperature-Rise and Pressure-Drop
    Sun, Jin
    Feng, Xiao
    Wang, Yufei
    PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3, 2014, 39 : 49 - 54