Pressure drop simulation and pipe size optimization in ammonia pump feeding refrigeration system

被引:0
|
作者
Research Institute of Energy Source and Motivity, Jimei University, Xiamen 361021, China [1 ]
机构
来源
Huagong Xuebao | 2008年 / SUPPL.卷 / 148-153期
关键词
Annual energy savings - Compressor suction - Performance parameters - Pressure drop model - Refrigeration compressors - Refrigeration system - Size optimization - Thermal parameters;
D O I
暂无
中图分类号
学科分类号
摘要
Mathematical models for pressure drop through both the compressor suction pipe and the evaporator returning pipe in ammonia pump feeding refrigeration system are developed. The system cycle's performance parameters are simulated by a computer program, which are developed based on both the pressure drop models and the thermal parameters models of the ammonia refrigerant. The program was used to simulate an ice making refrigeration loop with a capacity of 100 kW, a 102 m long compressor suction pipe and a 152 m long evaporator returning pipe. The simulation results show that, comparing to the traditional pipe selecting method, the pipe size optimized by the program is capable of increasing the system COP by 7.6% which corresponds to an annual energy saving of 9092 kWh. The further analysis shows the cost caused by the optimization can be recalled within two years. The life period of refrigeration compressor can be extended because its discharged temperature reduced evidently after pipe size optimization.
引用
收藏
页码:148 / 153
相关论文
共 50 条
  • [21] Failure analysis and optimization of high-pressure pipe in carbon dioxide heat pump air conditioning system
    Li, Ming
    Zhang, Yanji
    Liu, Yan
    Lu, Chunhong
    Chang, Wei
    ENGINEERING FAILURE ANALYSIS, 2024, 158
  • [22] Optimization of the Refrigeration System - A Dominant Factor in Planning Heat Pump Systems.
    Kerschbaumer, Gerhardt
    Fernwarme international, 1984, 13 (02): : 83 - 85
  • [23] Simulation-optimization approaches for water pump scheduling and pipe replacement problems
    Naoum-Sawaya, Joe
    Ghaddar, Bissan
    Arandia, Ernesto
    Eck, Bradley
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2015, 246 (01) : 293 - 306
  • [24] Pipe pressure drop and transfer bottle conveying characteristics in vertical pipe pneumatic logistics transmission system
    Wu, Banghan
    Lin, Dingbiao
    Lu, Haifeng
    Guo, Xiaolei
    Liu, Haifeng
    Huagong Xuebao/CIESC Journal, 2024, 75 (07): : 2465 - 2473
  • [25] Pressure Drop Control Using Multiple Orifice System in Compressible Pipe Flows
    Heuydong Kim School of Mechanical Engineering
    Journal of Thermal Science, 2001, (04) : 309 - 317
  • [26] Pressure drop control using multiple orifice system in compressible pipe flows
    Kim H.
    Setoguchi T.
    Matsuo S.
    Raghunathan S.R.
    Journal of Thermal Science, 2001, 10 (4) : 309 - 317
  • [27] Thermoeconomic evaluation and optimization of an aqua-ammonia vapour-absorption refrigeration system
    Misra, RD
    Sahoo, PK
    Gupta, A
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (01): : 47 - 59
  • [28] Simulation Study of the Pressure Control System for a Centrifugal Pump
    Gevorkov, Levon
    Vodovozov, Valery
    Raud, Zoja
    2016 57TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2016,
  • [29] NUMERICAL SIMULATION OF STRUCTURAL OPTIMIZATION FOR INLET PIPE OF CENTRIFUGAL PUMP IN CAP1400 POWER PLANT AUXILIARY SYSTEM
    Qu, Ting
    Zhang, Liang
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE2020), VOL 1, 2020,
  • [30] Experimental investigation on an ammonia-water-lithium bromide absorption refrigeration system without solution pump
    Wu, Tiehui
    Wu, Yuyuan
    Yu, Zhiqiang
    Zhao, Haichen
    Wu, Honglin
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (05) : 2314 - 2319