Determination of nine bisphenol analogues in human urine by high-throughput solid-phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis

被引:2
|
作者
Jin, Weiyi [1 ]
Yang, Siyu [1 ]
Yin, Longlong [2 ]
Jia, Yeqing [1 ]
Li, Xinghua [1 ]
An, Kang [3 ]
Li, Jianping [1 ]
Zhang, Yi [1 ]
机构
[1] Tianjin Ctr Dis Control & Prevent, Inst Hlth Inspection & Testing, 6 Huayue Rd, Tianjin 300011, Peoples R China
[2] Shandong Ctr Dis Control & Prevent, Jinan, Peoples R China
[3] Shandong First Med Univ Shandong Acad Med Sci, Sch Publ Hlth & Hlth Adm, 6699 Qingdao Rd, Jinan 250021, Shandong, Peoples R China
关键词
Bisphenol analogues; 96-well SPE; UHPLC-MS/MS; MRM-IDA-EPI; Urine;
D O I
10.1016/j.chroma.2024.465096
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bisphenol analogues (BPs) are a class of typical environmental endocrine-disrupting chemicals (EDCs). This study aimed to establish a highly sensitive and high-throughput method utilizing 96-well solid-phase extraction (96-well SPE) in conjunction with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) employing multiple reaction monitoring (MRM), information-dependent acquisition (IDA), and enhanced product ion (EPI) scan modes for the identification and quantitative analysis of nine BPs in human urine. Urine samples were initially thawed to room temperature, followed by digestion using beta-glucuronidase in an ammonium acetate buffer solution at 37 degrees C overnight. Subsequently, they were purified using 96-well SPE and finally analyzed by UHPLC-MS/MS. The limits of detection (LOD) for the nine BPs ranged from 0.05 mu g center dot kg-1- 1 to 0.3 mu g kg- 1 . Average recoveries fell within the range of 92.8 % to 111.7 %. Moreover, both the intra-day and inter-day precisions were satisfactory, with relative standard deviations (RSDs) ranging from 2.2 % to 6.7 % and 3.5 % to 6.3 %, respectively. The targets in the samples exhibited a perfect match, with a purity fit value exceeding 70 % from the self-built library. The analytical method developed in this study demonstrates high accuracy and sensitivity. In addition, the MRM-IDA-EPI mode can effectively identifies the target BPs and prevents false positive detection of analytes in the urine.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (06) : 436 - 445
  • [32] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (08) : 591 - 600
  • [33] DETERMINATION OF GINGEROLS IN GINGER BY ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Ashraf, Kamran
    Mujeeb, Mohd
    Ahmad, Altaf
    Ahmad, Sayeed
    Ahmad, Niyaz
    Amir, Mohd
    ANALYTICAL LETTERS, 2014, 47 (12) : 2120 - 2128
  • [34] Target Analysis of Antibiotic Drugs in Poultry Feedstuff by Solid Phase Extraction and Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Oyedeji, Abdulrasaq O.
    Benson, Nsikak U.
    Williams, Akan B.
    Msagati, Titus A. M.
    3RD INTERNATIONAL CONFERENCE ON SCIENCE AND SUSTAINABLE DEVELOPMENT (ICSSD 2019): SCIENCE, TECHNOLOGY AND RESEARCH: KEYS TO SUSTAINABLE DEVELOPMENT, 2019, 1299
  • [35] Determination of Organophosphate Esters and Metabolites in Serum and Urine by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Wu, Wen-Qi
    Wang, Xiao-Xia
    Liu, Wen-Bin
    Gao, Li-Rong
    Yu, Yang
    Jia, Tian-Qi
    Shi, Zhe-Yuan
    He, Yun-Chen
    Deng, Jing-Li
    Chen, Chun-Ci
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 52 (09) : 1346 - 1354
  • [36] Automatic on-line solid-phase extraction with ultra-high performance liquid chromatography and tandem mass spectrometry for the determination of ten antipsychotics in human plasma
    Zhong, Qisheng
    Shen, Lingling
    Liu, Jiaqi
    Yu, Dianbao
    Li, Simin
    Li, Zhiru
    Yao, Jinting
    Huang, Taohong
    Kawano, Shin-ichi
    Hashi, Yuki
    Zhou, Ting
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (11) : 2129 - 2137
  • [37] Improved Determination of Dichloroacetic and Trichloroacetic Acids in Water by Solid Phase Extraction Followed by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
    Kadmi, Yassine
    Favier, Lidia
    Ionut, Simion Andrei
    Matei, Ecaterina
    Wolbert, Dominique
    ANALYTICAL LETTERS, 2016, 49 (03) : 433 - 443
  • [38] Determination of chlorpropham residues in animal-derived foods by solid phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry
    Yang Lixia
    Huang Xiaobei
    Zeng Xike
    Yi Zi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2022, 40 (01) : 41 - 47
  • [39] Solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry for determination of trace rosiglitazone in urine
    Chou, CC
    Lee, MR
    Cheng, FC
    Yang, DY
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1097 (1-2) : 74 - 83
  • [40] Fast determination of 14 mycotoxins in chestnut by dispersive solid-phase extraction coupled with ultra high performance liquid chromatography-tandem mass spectrometry
    Liang, Jingyun
    Dong, Yanjie
    Yuan, Xuexia
    Fan, Lixia
    Zhao, Shancang
    Wang, Lei