Determination of nine bisphenol analogues in human urine by high-throughput solid-phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis

被引:0
|
作者
Jin W. [1 ]
Yang S. [1 ]
Yin L. [2 ]
Jia Y. [1 ]
Li X. [1 ]
An K. [3 ]
Li J. [1 ]
Zhang Y. [1 ]
机构
[1] Institute of Health Inspection and Testing, Tianjin Centers for Disease Control and Prevention, 6 Huayue Road, Hedong District, Tianjin
[2] Shandong Center for Disease Control and Prevention, Jinan
[3] School of Public Health and Health Administration, Shandong First Medical University & Shandong Academy of Medical Sciences, 6699 Qingdao Road, Jinan City, 250021, Shandong Province
关键词
96-well SPE; Bisphenol analogues; MRM-IDA-EPI; UHPLC-MS/MS; Urine;
D O I
10.1016/j.chroma.2024.465096
中图分类号
学科分类号
摘要
Bisphenol analogues (BPs) are a class of typical environmental endocrine-disrupting chemicals (EDCs). This study aimed to establish a highly sensitive and high-throughput method utilizing 96-well solid-phase extraction (96-well SPE) in conjunction with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) employing multiple reaction monitoring (MRM), information-dependent acquisition (IDA), and enhanced product ion (EPI) scan modes for the identification and quantitative analysis of nine BPs in human urine. Urine samples were initially thawed to room temperature, followed by digestion using β-glucuronidase in an ammonium acetate buffer solution at 37 °C overnight. Subsequently, they were purified using 96-well SPE and finally analyzed by UHPLC-MS/MS. The limits of detection (LOD) for the nine BPs ranged from 0.05 μg∙kg−1 to 0.3 μg kg−1. Average recoveries fell within the range of 92.8 % to 111.7 %. Moreover, both the intra-day and inter-day precisions were satisfactory, with relative standard deviations (RSDs) ranging from 2.2 % to 6.7 % and 3.5 % to 6.3 %, respectively. The targets in the samples exhibited a perfect match, with a purity fit value exceeding 70 % from the self-built library. The analytical method developed in this study demonstrates high accuracy and sensitivity. In addition, the MRM-IDA-EPI mode can effectively identifies the target BPs and prevents false positive detection of analytes in the urine. © 2024 Elsevier B.V.
引用
下载
收藏
相关论文
共 50 条
  • [21] Biomonitoring method for bisphenol A in human urine by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Anderson, David J.
    Brozek, Eric M.
    Cox, Kyley J.
    Porucznik, Christina A.
    Wilkins, Diana G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 953 : 53 - 61
  • [22] A multiclass method for the determination of pharmaceuticals in drinking water by solid phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry
    de Oliveira, Julia A.
    Izeppi, Lenise J. P.
    Loose, Roberta F.
    Muenchen, Daniela K.
    Prestes, Osmar D.
    Zanella, Renato
    ANALYTICAL METHODS, 2019, 11 (17) : 2333 - 2340
  • [23] Determination of Three Catecholamines in Livestock Meat by Solid Phase Extraction Combined with Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
    Ren, Nan
    Zhao, Wentao
    Chen, Chao
    Wu, Yanchao
    Zhang, Yingying
    Li, Yingying
    Guo, Wenping
    Fan, Wei
    Wang, Shouwei
    Shipin Kexue/Food Science, 2019, 40 (24): : 300 - 305
  • [24] Sensitive determination of a pharmaceutical compound and its metabolites in human plasma by ultra-high performance liquid chromatography-tandem mass spectrometry with on-line solid-phase extraction
    Heinig, K.
    Wirz, T.
    Bucheli, F.
    Monin, V.
    Gloge, A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (04) : 742 - 749
  • [25] Determination of Eugenol in Aquatic Products by Dispersive Solid-Phase Extraction and Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Sun, Peng
    Gao, Yuling
    Lian, Yongfu
    FOOD ANALYTICAL METHODS, 2017, 10 (10) : 3217 - 3224
  • [26] Determination of Eugenol in Aquatic Products by Dispersive Solid-Phase Extraction and Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Peng Sun
    Yuling Gao
    Yongfu Lian
    Food Analytical Methods, 2017, 10 : 3217 - 3224
  • [27] Development and validation of a high-throughput double solid phase extraction-liquid chromatography-tandem mass spectrometry method for the determination of tetrodotoxin in human urine and plasma
    Fong, Bonnie Mei-Wah
    Tam, Sidney
    Tsui, Sik-Hon
    Leung, Kelvin Sze-Yin
    TALANTA, 2011, 83 (03) : 1030 - 1036
  • [28] Determination of DCPTA in Mung Bean by Dispersive Solid-Phase Extraction and Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Gao, Yuling
    Li, WeiQing
    Li, Dongxue
    Yan, Rui
    Guo, Yongxia
    FOOD ANALYTICAL METHODS, 2020, 13 (08) : 1666 - 1672
  • [29] Determination of perfluormated compounds in human urine by ultra high performance liquid chromatography-tandem mass spectrometry
    Guo Feifei
    Wang Yuxin
    Li Jingguang
    Zhang Jialing
    Zhao Yunfeng
    Wu Yongning
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (02) : 126 - 130
  • [30] DETERMINATION OF GINGEROLS IN GINGER BY ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Ashraf, Kamran
    Mujeeb, Mohd
    Ahmad, Altaf
    Ahmad, Sayeed
    Ahmad, Niyaz
    Amir, Mohd
    ANALYTICAL LETTERS, 2014, 47 (12) : 2120 - 2128