Determination of nine bisphenol analogues in human urine by high-throughput solid-phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis

被引:2
|
作者
Jin, Weiyi [1 ]
Yang, Siyu [1 ]
Yin, Longlong [2 ]
Jia, Yeqing [1 ]
Li, Xinghua [1 ]
An, Kang [3 ]
Li, Jianping [1 ]
Zhang, Yi [1 ]
机构
[1] Tianjin Ctr Dis Control & Prevent, Inst Hlth Inspection & Testing, 6 Huayue Rd, Tianjin 300011, Peoples R China
[2] Shandong Ctr Dis Control & Prevent, Jinan, Peoples R China
[3] Shandong First Med Univ Shandong Acad Med Sci, Sch Publ Hlth & Hlth Adm, 6699 Qingdao Rd, Jinan 250021, Shandong, Peoples R China
关键词
Bisphenol analogues; 96-well SPE; UHPLC-MS/MS; MRM-IDA-EPI; Urine;
D O I
10.1016/j.chroma.2024.465096
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bisphenol analogues (BPs) are a class of typical environmental endocrine-disrupting chemicals (EDCs). This study aimed to establish a highly sensitive and high-throughput method utilizing 96-well solid-phase extraction (96-well SPE) in conjunction with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) employing multiple reaction monitoring (MRM), information-dependent acquisition (IDA), and enhanced product ion (EPI) scan modes for the identification and quantitative analysis of nine BPs in human urine. Urine samples were initially thawed to room temperature, followed by digestion using beta-glucuronidase in an ammonium acetate buffer solution at 37 degrees C overnight. Subsequently, they were purified using 96-well SPE and finally analyzed by UHPLC-MS/MS. The limits of detection (LOD) for the nine BPs ranged from 0.05 mu g center dot kg-1- 1 to 0.3 mu g kg- 1 . Average recoveries fell within the range of 92.8 % to 111.7 %. Moreover, both the intra-day and inter-day precisions were satisfactory, with relative standard deviations (RSDs) ranging from 2.2 % to 6.7 % and 3.5 % to 6.3 %, respectively. The targets in the samples exhibited a perfect match, with a purity fit value exceeding 70 % from the self-built library. The analytical method developed in this study demonstrates high accuracy and sensitivity. In addition, the MRM-IDA-EPI mode can effectively identifies the target BPs and prevents false positive detection of analytes in the urine.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determination of eight environmental phenols in human urine samples by high-throughput solid-phase extraction-ultra-performance liquid chromatography-tandem mass spectrometry
    Lin Xiao
    Qiu Tian
    Zhang Xu
    Hu Xiaojian
    Yang Yanwei
    Zhu Ying
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (12) : 1456 - 1464
  • [2] High-Throughput Analysis of Amphetamines in Blood and Urine with Online Solid-Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry
    Fernandez, Maria del Mar Ramirez
    Wille, Sarah M. R.
    Samyn, Nele
    Wood, Michelle
    Lopez-Rivadulla, Manuel
    De Boeck, Gert
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (09) : 578 - 587
  • [3] Determination of Bisphenol A and Bisphenol S in Drinking Water by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Solid-Phase Extraction
    Yang, Jinquan
    He, Xiaomin
    Shi, Minfang
    Chen, Hao
    Li, Yongrong
    Zhu, Youlin
    Shipin Kexue/Food Science, 2019, 40 (20): : 332 - 337
  • [4] Determination of Bisphenol A, Bisphenol F and Bisphenol S in Milk by High Liquid Chromatography-Tandem Mass Spectrometry with Solid-Phase Extraction
    Li X.
    Wang H.
    Zhang W.
    Zhang Y.
    Ba D.
    Ran L.
    Journal of Chinese Institute of Food Science and Technology, 2022, 22 (04): : 382 - 386
  • [5] DETERMINATION OF AFLATOXINS IN RICE AND MAIZE BY ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY WITH ACCELERATED SOLVENT EXTRACTION AND SOLID-PHASE EXTRACTION
    Li, Cheng
    Xie, Gang
    Lu, Anxiang
    Ping, Hua
    Ma, Zhihong
    Luan, Yunxia
    Wang, Jihua
    ANALYTICAL LETTERS, 2014, 47 (09) : 1485 - 1499
  • [6] Simultaneous determination of seven bisphenol analogues in surface water by solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry
    Wang, Qiuxu
    Feng, Qiyan
    Hu, Guanjiu
    Gao, Zhanqi
    Zhu, Xueqiang
    Epri, James Epua
    MICROCHEMICAL JOURNAL, 2022, 175
  • [7] Determination of Ellagic Acid in Wine by Solid-Phase Extraction–Ultra-High Performance Liquid Chromatography–Tandem Mass Spectrometry
    Rui Chen
    Jiaxuan Li
    Zhiwei Yang
    Fei Gao
    Pengyu Qi
    Xiang Li
    Fengmei Zhu
    Jun Li
    Jinjie Zhang
    Food Analytical Methods, 2019, 12 : 1103 - 1110
  • [8] Solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry
    Huang, Jin-Feng
    Xian, Yan-Ping
    Li, Xiu-Ying
    Cai, Wei-Hong
    Li, He
    Lin, Sen-Yu
    He, Min-Heng
    Guo, Xin-Dong
    Modern Food Science and Technology, 2014, 30 (12) : 241 - 246
  • [9] Automated high-throughput method using solid-phase microextraction-liquid chromatography-tandem mass spectrometry for the determination of ochratoxin A in human urine
    Vatinno, R.
    Vuckovic, D.
    Zambonin, C. G.
    Pawliszyn, J.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1201 (02) : 215 - 221
  • [10] An Ultra-High-Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry Method with Online Solid-Phase Extraction Sample Preparation for the High-Throughput and Sensitive Determination of Ostarine in Human Urine
    Sliz, Kristian
    Piestansky, Juraj
    Mikus, Peter
    METHODS AND PROTOCOLS, 2024, 7 (01)