Excess particle collection efficiency by a porous-metal substrate during inertial impaction process

被引:0
|
作者
Huang, C.-H. [1 ]
Tsai, C.-J. [1 ]
Shih, T.-S. [2 ]
机构
[1] Institute of Environmental Engineering, National Chiao Tung University, No. 75 Poai St., Hsin Chu, Taiwan
[2] Institute of Occupation Safety and Health, Council of Labor Affairs, Taipei, Taiwan
关键词
Air - Algorithms - Asymptotic stability - Curve fitting - Finite volume method - Flow measurement - Mathematical models - Navier Stokes equations - Nozzles - Particle size analysis;
D O I
暂无
中图分类号
学科分类号
摘要
The excess particle collection efficiency by a porous-metal substrate in an inertial impactor was investigated. Results indicated that the discrepancy between experimental data and theoretical results of particle collection efficiency is significant, especially for the case with a small nozzle diameter. This disagreement was due to excess particle collection resulting from air penetrating into the porous metal disk. The excess particle collection efficiency by the porous-metal substrate was investigated using numerical models.
引用
收藏
相关论文
共 50 条