Design and TEM simulation of a MEMS based microcantilever cardiac marker sensor

被引:1
|
作者
Vidhya S. [1 ]
Kumar G.P. [2 ]
Mathew L. [2 ]
机构
[1] Healthcare Practice, Frost and Sullivan P Ltd
[2] School of Biosciences and Technology, VIT University, Vellore
关键词
Acute myocardial infarction; Cardiac troponins; Microcantilever; Piezoresistive; Thermo-electromechanical analysis;
D O I
10.1115/1.3212821
中图分类号
学科分类号
摘要
Piezoresistive actuation of a microcantilever induced by biomolecular binding such as DNA hybridization and antibody-antigen binding is an important principle useful in biosensing applications. As the magnitude of the forces exerted is small, increasing the sensitivity of the microcantilever becomes critical. In this paper, we are considering to achieve this by geometric variation in the cantilever. The sensitivity of the cantilever was improved so that the device can sense the presence of antigen even if the magnitude of surface-stresses over the microcantilever was very small. We consider a "T-shaped" cantilever that eliminates the disadvantages while improving the sensitivity simultaneously. Simulations for validation have been performed using INTELLISUITE software (a micro-electromechanical system design and simulation package). The simulations reveal that the T-shaped microcantilever is almost as sensitive as a thin cantilever and has relatively very low buckling effect. Simulations also reveal that with an increase in thickness of the cantilever, there is a proportional decrease in the sensitivity. © 2010 by ASME.
引用
收藏
相关论文
共 50 条
  • [41] A novel design of a MEMS based tactile sensor
    Singh, R
    DESIGN, CHARACTERIZATION, AND PACKAGING FOR MEMS AND MICROELECTRONICS, 1999, 3893 : 250 - 261
  • [42] DESIGN AND FABRICATION OF A MICROCANTILEVER-BASED SENSOR FOR NERVE GAS DETECTION
    Li, Chengzhang
    Miller, Michele H.
    Nayyar, Jaspreet Singh
    Velayudham, Singaravelu
    Bergstrom, Paul L.
    Liu, Haiying
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE 2010), VOL 10, 2012, : 627 - 634
  • [43] A Hydrogen Sensor Based on Pd-Functionalized Microcantilever with Surface Design
    Chou, Yen-I
    Chiang, Hsu-Cheng
    Wang, Chi-Chuan
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2007, 10 (02): : 159 - 162
  • [44] A hydrogen sensor based on Pd-functionalized microcantilever with surface design
    Energy and Environment Laboratories, Industrial Technology Research Institute, Hsinchu, 310, Taiwan
    Tamkang J. Sci. Eng., 2007, 2 (159-162): : 159 - 162
  • [45] Design and simulation of a MEMS high G inertial impact sensor
    Wang, Y. P.
    Hsu, R. Q.
    Wu, C. W.
    2008 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2008, : 95 - +
  • [46] Design, Modeling and Simulation of MEMS Resonator for Humidity Sensor Application
    Mutharpavalar, Ashaashvini
    Ahmed, A. Y.
    Nor, Nursyarizal Mohd
    2020 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2020), 2020,
  • [47] Design and simulation of a piezoresistive MEMS pressure sensor for marine applications
    Aravamudhan, S
    Bhansali, S
    MULTIPHASE PHENOMENA AND CFD MODELING AND SIMULATION IN MATERIALS PROCESSES, 2004, : 347 - 355
  • [48] Simulation and design of a microcantilever for biosensing application
    Ion, M.
    Pachiu, C.
    Moldovan, C.
    CAS 2007 INTERNATIONAL SEMICONDUCTOR CONFERENCE, VOLS 1 AND 2, PROCEEDINGS, 2007, : 143 - 146
  • [49] Design and Analysis of MEMS based Cantilever Sensor for the Detection of Cardiac Markers in Acute Myocardial Infarction
    Vidhya, Sree
    Mathew, Lazar
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 810 - +
  • [50] Sensitivity Enhancement of MEMS Tactile Sensor by Redesign of Microcantilever and Strain Gauge
    Kaneta, Ren
    Hasegawa, Takumi
    Abe, Takashi
    Sohgawa, Masayuki
    2021 IEEE SENSORS, 2021,