Optimal phase sequence of 750 kV four-circuit transmission lines considering electromagnetic environment

被引:0
|
作者
Wang S. [1 ]
Zhang P. [1 ]
Feng N. [2 ]
Si Z. [3 ]
Yang F. [3 ]
Gao F. [1 ]
Shen W. [1 ]
机构
[1] State Grid Shaanxi Electric Power Research Institute, Xi’an, 710100, Shaanxi Province
[2] State Grid Shaanxi Electric Power Corporation, Xi’an
[3] State Key Laboratory of Power Transmission Equipment & System Security and New Technology (Chongqing University), Chongqing
关键词
16;
D O I
10.2528/PIERM19082805
中图分类号
学科分类号
摘要
In order to evaluate the electromagnetic environment of 750 kV four-circuit transmission lines accurately and design the optimal tower type and phase sequence of the four-circuit lines, the finite element method is used to analyze the distribution characteristics of power frequency electromagnetic field under the line. The excitation function method and empirical formula method are used to calculate the radio interference and audible noise distribution under the line, respectively. Electromagnetic environment parameters of various phase sequences of two tower types are analyzed to determine the optimal phase sequence of 750 kV four-circuit transmission lines. The results show that the electromagnetic environment of transmission lines is strongly influenced by different tower types and phase sequences. The magnetic flux density and radio interference of the various phase sequences of the two tower types reach the limit of code, and 43.52% and 64.81% phase sequences reach the audible noise limit conditions, respectively. Electric field intensity is a main influence factor of electromagnetic environment. The optimal phase sequence layouts of the two tower types are 1661 and 1522, and the electric field intensities are 9.66 kV/m and 9.12 kV/m. The calculation method and results can be used for reference in practical engineering. © 2020, Electromagnetics Academy. All rights reserved.
引用
收藏
页码:201 / 209
页数:8
相关论文
共 50 条
  • [41] Electromagnetic Environment of 750 kV Economical Fault Current Limiter Under Power Frequency Short-circuit
    Hou D.
    Liu J.
    Liu C.
    Zou J.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (11): : 4638 - 4646
  • [43] Study on electromagnetic environment of ±800 kV UHV DC and 1000 kV UHV AC parallel transmission lines
    Wang, Guangzhou
    Yao, Degui
    Zhang, Songyang
    Wang, Donghui
    Wang, Leilei
    Guo, Xing
    Yang, Fan
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [44] Novel scheme of fault phase selection for mixed-voltage four-circuit lines on same tower based on waveform correlation
    Zheng T.
    Yu S.
    Wu J.
    Luo M.
    Zheng, Tao (zhengtao_sf@126.com), 1600, Electric Power Automation Equipment Press (40): : 138 - 143and149
  • [45] Calculation and Analysis on Unbalanced Currents of Yandun-Tianshan 750kV Double-circuit Transmission Lines
    Wang X.
    Xiang Z.
    Song X.
    Liang S.
    Li S.
    Wang C.
    Fu T.
    Dianwang Jishu/Power System Technology, 2022, 46 (07): : 2842 - 2849
  • [46] Numerical analysis of potential distribution of porcelain insulator strings for 750 kV double-circuit transmission lines on the same tower
    Liu, Yu-Gen
    Tian, Jin-Hu
    Liu, Xiao-Wei
    Cheng, Xi
    Xiao, Lei-Shi
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (07): : 1644 - 1650
  • [47] Analysis of ecological environment for 500kV four circuits power transmission lines on same tower
    Zhang, Bingyi
    Wang, Xiaohui
    Zhao, Min
    Zhao, Yisong
    Wang, Xiaoyan
    Feng, Guihong
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 764 - +
  • [48] DEVICE FOR SINGLE- AND TRIPLE-PHASE AUTOMATIC RECLOSURE OF 500-750 kv TRANSMISSION LINES.
    Strelkov, V.I.
    Fokin, G.G.
    Yakubson, G.G.
    Kostina, A.D.
    Soviet electrical engineering, 1985, 56 (03): : 30 - 35
  • [49] Study on Electromagnetic Environment of ±500 kV Triple-circuit Flexible DC Transmission Line on Same Tower
    Ma X.
    He K.
    Xie L.
    Lu J.
    Ju Y.
    Ma, Xiaoqian (mxqian228@163.com), 1978, Power System Technology Press (44): : 1978 - 1984
  • [50] Influence of zero-sequence mutual inductance on earth-fault distance protection for four-circuit transmission lines belonging to different voltage classes on same tower under different operation modes
    Zhao, Kaichao
    Zhou, Zexin
    Du, Dingxiang
    Dianwang Jishu/Power System Technology, 2010, 34 (12): : 193 - 197