Optimal phase sequence of 750 kV four-circuit transmission lines considering electromagnetic environment

被引:0
|
作者
Wang S. [1 ]
Zhang P. [1 ]
Feng N. [2 ]
Si Z. [3 ]
Yang F. [3 ]
Gao F. [1 ]
Shen W. [1 ]
机构
[1] State Grid Shaanxi Electric Power Research Institute, Xi’an, 710100, Shaanxi Province
[2] State Grid Shaanxi Electric Power Corporation, Xi’an
[3] State Key Laboratory of Power Transmission Equipment & System Security and New Technology (Chongqing University), Chongqing
关键词
16;
D O I
10.2528/PIERM19082805
中图分类号
学科分类号
摘要
In order to evaluate the electromagnetic environment of 750 kV four-circuit transmission lines accurately and design the optimal tower type and phase sequence of the four-circuit lines, the finite element method is used to analyze the distribution characteristics of power frequency electromagnetic field under the line. The excitation function method and empirical formula method are used to calculate the radio interference and audible noise distribution under the line, respectively. Electromagnetic environment parameters of various phase sequences of two tower types are analyzed to determine the optimal phase sequence of 750 kV four-circuit transmission lines. The results show that the electromagnetic environment of transmission lines is strongly influenced by different tower types and phase sequences. The magnetic flux density and radio interference of the various phase sequences of the two tower types reach the limit of code, and 43.52% and 64.81% phase sequences reach the audible noise limit conditions, respectively. Electric field intensity is a main influence factor of electromagnetic environment. The optimal phase sequence layouts of the two tower types are 1661 and 1522, and the electric field intensities are 9.66 kV/m and 9.12 kV/m. The calculation method and results can be used for reference in practical engineering. © 2020, Electromagnetics Academy. All rights reserved.
引用
收藏
页码:201 / 209
页数:8
相关论文
共 50 条
  • [21] Research for the Maintenance Way of Partial Outage on 500kv/220 kV Four-circuit Mixed-voltage Transmission Lines on the Same Tower
    Li, Jinliang
    Wang, Zhigang
    Xia, Zengming
    Wang, Tiqing
    Zeng, Wenyuan
    Yan, Yu
    Yang, Qi
    Li, Wen
    Long, Chenhai
    Ren, Huisong
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [22] Research on electromagnetic environment of ±800 kV and ±500 kV double-circuit DC transmission lines on the same tower
    Wu, Gaobo
    Li, Jian
    Chen, Yuan
    Luo, Chujun
    Wang, Rusong
    Lin, Fang
    Dianwang Jishu/Power System Technology, 2015, 39 (09): : 2532 - 2538
  • [23] Analysis of the performance of a phase selector for a cross-voltage fault in mixed-voltage four-circuit transmission lines and countermeasures
    Zheng T.
    Wu Q.
    Yu S.
    Wu J.
    Wang X.
    Luo M.
    He J.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (08): : 44 - 51
  • [24] New method of measuring the zero-sequence distributed parameters of non-full-line parallel four-circuit transmission lines
    Mou, Hongjiang
    Hu, Zhijian
    Gao, Mingxin
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 139
  • [25] The Optimal Phase Sequence Arrangement of Multi-circuit Transmission Lines on the Same Tower
    Li, Helong
    Wang, Xueming
    Zhao, Jinquan
    Zheng, Zhibin
    2017 13TH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, FUZZY SYSTEMS AND KNOWLEDGE DISCOVERY (ICNC-FSKD), 2017, : 2525 - 2529
  • [26] Performance research on ZigBee wireless sensor network self-organizing network for 220 kV four-circuit transmission lines on the same tower
    Zhou, Te
    Yang, Chao
    Chen, Honghu
    Han, Yang
    Bao, Weihan
    Cheng, Qing
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 53
  • [27] Performance analysis of a zero-sequence directional relay for a single-circuit fault in mixed-voltage four-circuit transmission lines on the same tower
    Liu Z.
    Gao H.
    Guo Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (24): : 1 - 12
  • [28] Voltage Sharing Characteristics of Full Composite Cross Arm and Semi-composite Cross Arm of 500 kV Four-circuit Transmission Lines
    Liu C.
    Zhang X.
    Liu P.
    Zhang H.
    Ye Z.
    Peng Z.
    Zhao Y.
    Dianwang Jishu/Power System Technology, 2022, 46 (10): : 4131 - 4139
  • [29] Deep learning-based fault location using PMU in tapped four-circuit transmission lines
    Zhiyu Yan
    Yanan Yang
    International Journal of Dynamics and Control, 2024, 12 : 1270 - 1278
  • [30] Deep learning-based fault location using PMU in tapped four-circuit transmission lines
    Yan, Zhiyu
    Yang, Yanan
    INTERNATIONAL JOURNAL OF DYNAMICS AND CONTROL, 2024, 12 (05) : 1270 - 1278