Optimal phase sequence of 750 kV four-circuit transmission lines considering electromagnetic environment

被引:0
|
作者
Wang S. [1 ]
Zhang P. [1 ]
Feng N. [2 ]
Si Z. [3 ]
Yang F. [3 ]
Gao F. [1 ]
Shen W. [1 ]
机构
[1] State Grid Shaanxi Electric Power Research Institute, Xi’an, 710100, Shaanxi Province
[2] State Grid Shaanxi Electric Power Corporation, Xi’an
[3] State Key Laboratory of Power Transmission Equipment & System Security and New Technology (Chongqing University), Chongqing
关键词
16;
D O I
10.2528/PIERM19082805
中图分类号
学科分类号
摘要
In order to evaluate the electromagnetic environment of 750 kV four-circuit transmission lines accurately and design the optimal tower type and phase sequence of the four-circuit lines, the finite element method is used to analyze the distribution characteristics of power frequency electromagnetic field under the line. The excitation function method and empirical formula method are used to calculate the radio interference and audible noise distribution under the line, respectively. Electromagnetic environment parameters of various phase sequences of two tower types are analyzed to determine the optimal phase sequence of 750 kV four-circuit transmission lines. The results show that the electromagnetic environment of transmission lines is strongly influenced by different tower types and phase sequences. The magnetic flux density and radio interference of the various phase sequences of the two tower types reach the limit of code, and 43.52% and 64.81% phase sequences reach the audible noise limit conditions, respectively. Electric field intensity is a main influence factor of electromagnetic environment. The optimal phase sequence layouts of the two tower types are 1661 and 1522, and the electric field intensities are 9.66 kV/m and 9.12 kV/m. The calculation method and results can be used for reference in practical engineering. © 2020, Electromagnetics Academy. All rights reserved.
引用
收藏
页码:201 / 209
页数:8
相关论文
共 50 条
  • [1] Optimal Phase Sequence of 750 kV Four-Circuit Transmission Lines Considering Electromagnetic Environment
    Wang, Sen
    Zhang, Peng
    Feng, Nanzhan
    Si, Zhanchao
    Yang, Fan
    Gao, Feng
    Shen, Wei
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2020, 88 : 201 - 209
  • [2] Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological Conditions
    Liu, Yunpeng
    Chen, Sijia
    Huang, Shilong
    IEEE ACCESS, 2018, 6 : 67427 - 67433
  • [3] Investigation on the Electromagnetic Interference of Four-circuit Transmission Lines
    Zhuang Xiaoyun
    Li Yongming
    Ma Jun
    SPORTS, ARTS MATERIALS AND MANAGEMENT SCIENCE, 2012, 507 : 106 - +
  • [4] Conductor Arrangement and Phase Sequence Optimization Scheme for 500 kV Four-Circuit Transmission Lines on Same Tower
    Lu D.
    Lang X.
    Yang B.
    Li Z.
    Geng H.
    Energy Engineering: Journal of the Association of Energy Engineering, 2023, 120 (10): : 2287 - 2306
  • [5] Electromagnetic environment of 750 kV single-circuit compact transmission lines
    Wan, Bao-Quan
    Wu, Xiong
    Zhang, Ye-Mao
    Cao, Sheng-Shun
    Zhu, Yue
    Liu, Da-Shi
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (03): : 597 - 600
  • [6] Research on phase conductors configuration of parallel four-circuit transmission lines on the same tower
    School of Electrical Engineering, Wuhan University, Wuhan 430072, China
    不详
    Gaodianya Jishu, 2006, 3 (18-20):
  • [7] Corona Loss of 750 kV Four-circuit Lines with Six-layer Cross-arms on the Same Tower
    Liu Y.
    Huang S.
    Chen S.
    Liu Q.
    Huo F.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (04): : 1118 - 1123
  • [10] Method for Parameter Decoupling for Four-circuit Transmission Lines on The Same Tower
    Su Zhipeng
    Wang Pingping
    Yang Zheng
    Xu, Zhenyu
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,