Longitudinal monitoring of reconstructed activity concentration on a clinical time-of-flight PET/CT scanner

被引:1
|
作者
MacDonald L.R. [1 ]
Perkins A.E. [2 ]
Tung C.-H. [2 ]
机构
[1] University of Washington, Radiology Department, 1715 Northeast Columbia Road, Box 357987, Seattle, 98195-7987, WA
[2] Philips Healthcare, 595 Miner Road, Highland Heights, 44143, OH
基金
美国国家卫生研究院;
关键词
PET/CT; quality control procedure; quantitative imaging biomarker; quantitative imaging biomarker alliance; SUV variance;
D O I
10.1117/1.JMI.4.1.011004
中图分类号
学科分类号
摘要
Positron emission tomography (PET) images are potential quantitative biomarkers. Understanding long-term (months/years) biomarker variability is important for establishing confidence intervals on studies using such biomarkers over these time frames. PET biomarkers are derived from activity concentration (ρ) extracted from PET images. Over 30 months, we measured the stability of decay-normalized counts (Nn) and ρ by scanning the same 4.5-cm-diameter Ge-68 cylinder weekly, the same Na-22 point source daily, and a refilled 20-cm F-18 cylinder phantom monthly on a clinical TOF-PET/CT scanner. Longitudinal and adjacent-measurement variability was characterized. We found no drift in ρ or Nn for properly calibrated images over 24 months. During this time, ρmean ranged ±5% to 6% for count-matched Ge-68 and F-18 images, with coefficient of variation (COV) across time of 2.3% (Ge-68, 81 scans) and 3.2% (F-18, 24 scans). At typical patient image count levels the Ge-68 ρmean (ρmax) COV across time was 6.9% (9.6%). Changes in ρmean between adjacent F-18 scans (Δdays=34) ranged between ±10%, with corresponding date-matched changes in Ge-68 ρmean ranging ±2%. We recommend (1) tracking trends in Nn with image ρ as a check of quantitative data corrections/calibrations and (2) tracking both mean and COV of ρ (single time point measures) to hundredths precision using standardized uptake values. © 2016 Society of Photo-Optical Instrumentation Engineers (SPIE).
引用
收藏
相关论文
共 50 条
  • [21] An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging
    Lois, Cristina
    Jakoby, Bjoern W.
    Long, Misty J.
    Hubner, Karl F.
    Barker, David W.
    Casey, Michael E.
    Conti, Maurizio
    Panin, Vladimir Y.
    Kadrmas, Dan J.
    Townsend, David W.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) : 237 - 245
  • [22] EVALUATION OF FRACTIONAL ERRORS IN PIXELS AND REGIONS IN A TIME-OF-FLIGHT PET SCANNER
    CINOTTI, L
    LAVENNE, F
    LEBARS, D
    LANDAIS, P
    CAMPAGNOLO, R
    ROUSSET, O
    MAUGUIERE, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (08): : 1113 - 1120
  • [23] First experimental results of time-of-flight reconstruction on an LSO PET scanner
    Conti, M
    Bendriem, B
    Casey, M
    Chen, M
    Kehren, F
    Michel, C
    Panin, V
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19): : 4507 - 4526
  • [24] Time-of-Flight PET
    Lewellen, TK
    SEMINARS IN NUCLEAR MEDICINE, 1998, 28 (03) : 268 - 275
  • [25] Using time-of-flight information for PET, PET/CT and PET/MRI reconstruction
    Nuyts, Johan
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (01):
  • [26] Optimisation of penalized likelihood estimation reconstruction on a digital time-of-flight PET-CT scanner for four different PET tracers
    Lindstrom, E.
    Sundin, A.
    Trampal, C.
    Lindsjo, L.
    Sorensen, J.
    Lubberink, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S341 - S342
  • [27] Protocol Optimisation of [68Ga]-PSMA PET/CT Imaging on a High Sensitivity Time-of-Flight Pet Scanner\c
    Bailey, E. A.
    Hsiao, E.
    Schembri, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S93 - S94
  • [28] A quantitative clinical evaluation of simultaneous reconstruction of attenuation and activity in time-of-flight PET
    Haiqiong Zhang
    Jingnan Wang
    Nan Li
    Yue Zhang
    Jie Cui
    Li Huo
    Hui Zhang
    BMC Medical Imaging, 23
  • [29] A quantitative clinical evaluation of simultaneous reconstruction of attenuation and activity in time-of-flight PET
    Zhang, Haiqiong
    Wang, Jingnan
    Li, Nan
    Zhang, Yue
    Cui, Jie
    Huo, Li
    Zhang, Hui
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [30] Performance of philips gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities
    Surti, Suleman
    Kuhn, Austin
    Werner, Matthew E.
    Perkins, Amy E.
    Kolthammer, Jeffrey
    Karp, Joel S.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (03) : 471 - 480