A simple method for partial volume effect correction in PET images

被引:0
|
作者
Department of Nuclear Medicine, General Hospital of PLA, Beijing 100853, China [1 ]
不详 [2 ]
机构
来源
Hedianzixue Yu Tance Jishue | 2007年 / 6卷 / 1231-1238期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The partial volume effects (PVE) make the lesion distorted in PET images, which influences clinical diagnosis. A PVE correction method was set up in this study. According to the principle causing PVE, the relationships between the characteristic profiles of the transversal slice and the image of one dimension lesion were investigated based on a large of simulate experiment results for cylindrical lesions. The PVE correction for two dimension lesion image was simplified to perform with one dimension lesion image. It was named one dimension correction. Then the correction method was evaluated with the phantom study. Results: (1) One dimension correction method: The procedure of PVE correction consisted of three steps and the corrected value of lesion' size and radioactivity concentration were formulated. (2) Results of evaluation with the phantom study: The lesions' sizes and radioactivity concentrations were corrected satisfactorily, and the differences between the corrected and the true values were within 6% and 7% for the lesions larger than the system resolution (FWHM). For the smaller lesion, because of the heavier PVE there were much difference between the uncorrected and the true values of lesion' sizes and radioactivity concentrations, it reached more than 80%; it was reduced to about half after correction. A PVE correction approach for PET images of two dimension lesions, the one dimension correction, was proposed. It was simple and fast, and the correction results were satisfactory.
引用
收藏
页码:1231 / 1238
相关论文
共 50 条
  • [31] Deconvolution-based partial volume correction of PET images with parallel level set regularization
    Zhu, Yansong
    Bilgel, Murat
    Gao, Yuanyuan
    Rousset, Olivier G.
    Resnick, Susan M.
    Wong, Dean F.
    Rahmim, Arman
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (14):
  • [32] HIGHLY PRECISE PARTIAL VOLUME CORRECTION FOR PET IMAGES: AN ITERATIVE APPROACH VIA SHAPE CONSISTENCY
    Xu, Ziyue
    Bagci, Ulas
    Gao, Mingchen
    Mollura, Daniel J.
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1196 - 1199
  • [33] A simple algorithm for subregional striatal uptake analysis with partial volume correction in dopaminergic PET imaging
    Kun-Han Lue
    Hsin-Hon Lin
    Chih-Hao K. Kao
    Hung-Jen Hsieh
    Shu-Hsin Liu
    Keh-Shih Chuang
    Annals of Nuclear Medicine, 2014, 28 : 33 - 41
  • [34] A simple algorithm for subregional striatal uptake analysis with partial volume correction in dopaminergic PET imaging
    Lue, Kun-Han
    Lin, Hsin-Hon
    Kao, Chih-Hao K.
    Hsieh, Hung-Jen
    Liu, Shu-Hsin
    Chuang, Keh-Shih
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (01) : 33 - 41
  • [35] Partial volume effect estimation and correction in the aortic vascular wall in PET imaging
    Burg, S.
    Dupas, A.
    Stute, S.
    Dieudonne, A.
    Huet, P.
    Le Guludec, D.
    Buvat, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7527 - 7542
  • [36] An Investigation of Partial Volume Effect and Partial Volume Correction in Small Animal Positron Emission Tomography (PET) of the Rat Brain
    Lehnert, Wencke
    Gregoire, Marie-Claude
    Hu, Xiao
    Meikle, Steven R.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4485 - +
  • [37] Correction for partial volume effects in PET: Principle and validation
    Rousset, OG
    Ma, YL
    Evans, AC
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 904 - 911
  • [38] Extravascular density model for PET partial volume correction
    Wassenaar, Richard W.
    deKemp, Robert A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1809 - 1813
  • [39] Performance evaluation of PMOD integrated partial volume correction method for brain PET data
    Barret, Olivier
    Mularczyk, Pawel
    Mikolajczyk, Krzysztof
    Burger, Cyrill
    NEUROIMAGE, 2010, 52 : S10 - S10
  • [40] The effect of partial volume effect correction on PIB and FDG PET data in MCI and AD patients
    Shiga, Tohru
    Miederer, Isabelle
    Herrmann, Ken
    Henriksen, Gjermund
    Praus, Christine
    Schwaiger, Markus
    Drzezga, Alexander
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50