A study of structural effects on the focusing and imaging performance of hard X-rays with 20-30 nm zone plates

被引:1
|
作者
Tong, Xujie [1 ]
Dhamgaye, Vishal [2 ]
Chen, Qiucheng [1 ]
Wu, Qingxin [1 ]
Deng, Biao [3 ]
Zhang, Ling [3 ]
Fox, Oliver [2 ]
Wang, Hongchang [2 ]
Zhao, Jun [1 ,3 ]
Chen, Yifang [1 ]
Xu, Zijian [3 ]
Li, Peng [2 ]
Sawhney, Kawal [2 ]
机构
[1] Fudan Univ, Sch Informat Sci & Technol, Shanghai Key Lab Metasurfaces Light Manipulat, Nanolithog & Applicat Res Grp, Shanghai 200433, Peoples R China
[2] Diamond Light Source Ltd, Harwell Sci & Innovat Campus, Didcot OX11 0DE, Oxon, England
[3] Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai Synchrotron Radiat Facil, Shanghai 201210, Peoples R China
基金
中国国家自然科学基金;
关键词
zone plates; zone structural effects; focusing efficiency; X-ray microscopy; beam-propagation method; NANOFABRICATION;
D O I
10.1107/S1600577524009615
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hard X-ray microscopes with 20-30 nm spatial resolution ranges are an advanced tool for the inspection of materials at the nanoscale. However, the limited efficiency of the focusing optics, for example, a Fresnel zone plate (ZP) lens, can significantly reduce the power of a nanoprobe. Despite several reports on ZP lenses that focus hard X-rays with 20 nm resolution - mainly constructed by zone-doubling techniques - a systematic investigation into the limiting factors has not been reported. We report the structural effects on the focusing and imaging efficiency of 20-30 nm-resolution ZPs, employing a modified beam-propagation method. The zone width and the duty cycle (zone width/ring pitch) were optimized to achieve maximum efficiency, and a comparative analysis of the zone materials was conducted. The optimized zone structures were used in the fabrication of Pt-hydrogen silsesquioxane (HSQ) ZPs. The highest focusing efficiency of the Pt-HSQ-ZP with a resolution of 30 nm was 10% at 7 keV and >5% in the range 6-10 keV, whereas the highest efficiency of the Pt-HSQ-ZP with a resolution of 20 nm was realized at 7 keV with an efficiency of 7.6%. Optical characterization conducted at X-ray beamlines demonstrated significant enhancement of the focusing and imaging efficiency in a broader range of hard X-rays from 5 keV to 10 keV, demonstrating the potential application in hard X-ray focusing and imaging.
引用
收藏
页码:1457 / 1463
页数:7
相关论文
共 35 条
  • [31] Tomographic imaging based on scattered radiation from polyethylene using 10, 15, 20, 25 and 30 keV synchrotron X-rays with simple approximations
    Rao, DV
    Yuasa, T
    Akatsuka, T
    Tromba, G
    Hasan, MZ
    Takeda, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (03): : 209 - 216
  • [32] Performance of Magnetic Resonance Imaging in Detection of Chronic Structural Changes in Sacroiliac Joints As Compared to Conventional X-Rays in Axial Spondyloarthritis.
    Poddubnyy, Denis
    Gaydukova, Inna
    Haibel, Hildrun
    Song, In-Ho
    Sieper, Joachim
    ARTHRITIS AND RHEUMATISM, 2012, 64 (10): : S244 - S244
  • [33] ARE X-RAYS THE ADEQUATE IMAGING MODALITY FOR STRUCTURAL DAMAGE ASSESSMENT OF THE SACRO-ILIAC JOINTS? COMPARATIVE STUDY OF 29 SPONDYLOARTHRITIS PATIENTS WITH STRUCTURAL DAMAGE OF THE SACROILIAC JOINTS AND 48 CONTROLS
    Molto, A.
    Freire, V.
    Feydy, A.
    Paternotte, S.
    Maksyrnowych, W. P.
    Benhamou, M.
    Rannou, F.
    Dougados, M.
    Gossec, L.
    ANNALS OF THE RHEUMATIC DISEASES, 2014, 73 : 1113 - 1113
  • [34] The Performance of Radiography (X-rays) of the Sacroiliac Joints (SIJ) in Comparison with Magnetic Resonance Imaging (MRI) Studies in Individuals with Inflammatory Back Pain (IBP) Identified in a Community Study
    Muela, Y.
    Casasola-Vargas, J. C.
    Pelaez-Ballestas, I
    Burgos-Vargas, R.
    JOURNAL OF RHEUMATOLOGY, 2011, 38 (06) : 1192 - 1192
  • [35] STRUCTURAL STUDY USING X-RAYS ON HYDRATED COMPLEX CR207MG.2((CH2)6N4).6H20
    DAHAN, F
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE C, 1971, 273 (14): : 805 - &