RELAP5-3D validation studies based on the High Temperature Test facility

被引:0
|
作者
Kile, Robert F. [1 ,2 ]
Epiney, Aaron S. [2 ]
Brown, Nicholas R. [1 ]
机构
[1] Univ Tennessee, Knoxville, TN 37996 USA
[2] Idaho Natl Lab, Idaho Falls, ID USA
关键词
Gas-cooled reactor; Thermal hydraulics; Benchmark; Reactor safety; HTTF; Validation; RELAP5-3D; HTTR; BENCHMARK;
D O I
10.1016/j.nucengdes.2024.113401
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. We developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5-3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code's capabilities for HTGR modeling with a more finely nodalized model.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] THERMAL MODELING OF THE HTR-10 USING THE RELAP5-3D CODE
    Scari, Maria Elizabeth
    Costa, Antonella Lombardi
    Pereira, Claubia
    Mello da Silva, Clarysson Alberto
    Fortini Veloso, Maria Auxiliadora
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2A, 2014,
  • [42] 基于RELAP5-3D钠物性模型改造及验证
    谭伟
    袁显宝
    阮杨
    科技资讯, 2024, 22 (05) : 98 - 101
  • [43] New Simulation Schemes and Capabilities for the PHISICS/RELAP5-3D Coupled Suite
    Rabiti, C.
    Alfonsi, A.
    Epiney, A.
    NUCLEAR SCIENCE AND ENGINEERING, 2016, 182 (01) : 104 - 118
  • [44] Comparative RELAP5-3D analysis in support of the NPP DBA analysis in Ukraine
    Shkarupa, A.
    Kadenko, I.
    Malanich, A.
    Kovtonyuk, A.
    Ivanov, K.
    PROGRESS IN NUCLEAR ENERGY, 2006, 48 (08) : 891 - 911
  • [45] BWR Station Blackout: A RISMC Analysis Using RAVEN and RELAP5-3D
    Mandelli, D.
    Smith, C.
    Riley, T.
    Nielsen, J.
    Alfonsi, A.
    Cogliati, J.
    Rabiti, C.
    Schroeder, J.
    NUCLEAR TECHNOLOGY, 2016, 193 (01) : 161 - 174
  • [46] A knowledge gap analysis for transient CHF prediction within RELAP5-3D
    Meehan, Nicholas A.
    Folsom, Charles P.
    Brown, Nicholas R.
    NUCLEAR ENGINEERING AND DESIGN, 2024, 422
  • [47] A RELAP5-3D/LSTM model for the analysis of drywell cooling fan failure
    Guillen, D. P.
    Anderson, N.
    Krome, C.
    Boza, R.
    Griffel, L. M.
    Zouabe, J.
    Al Rashdan, A. Y.
    PROGRESS IN NUCLEAR ENERGY, 2020, 130
  • [48] Development of an Integrated Code System Using R5EXEC and RELAP5-3D
    Aumiller, David
    Buschman, Francis
    Tomlinson, Edward
    Gill, Daniel
    NUCLEAR TECHNOLOGY, 2016, 193 (01) : 183 - 199
  • [49] Implementation and Assessment of Moody Homogeneous Equilibrium Critical Flow Model of RELAP5-3D
    Dai, Liang-Che
    Yang, Chung-Yu
    Yuann, Yng-Ruey
    Pei, Bau-Shei
    Shih, Chun-Kuan
    NUCLEAR SCIENCE AND ENGINEERING, 2016, 182 (01) : 96 - 103
  • [50] Improvement of the RELAP5-3D condensation heat transfer model in the presence of noncondensable gases
    Anderson N.
    Sabharwall P.
    Sabharwall, Piyush (piyush.sabharwall@inl.gov), 1600, American Society of Mechanical Engineers (ASME) (142):