Experimental study of transformer residual flux and the method of restraining inrush current

被引:0
|
作者
机构
[1] Hase, Yoshihide
[2] Kamesawa, Tomoyuki
[3] Inoue, Shinji
[4] Yamamura, Shunichiro
来源
| 1600年 / John Wiley and Sons Inc卷 / 188期
关键词
SUMMARY Whenever a power transformer in a no-load condition is manually tripped; a residual flux appears in the transformer core; which causes an inrush current when the transformer is later re-energized. However; the true nature of residual fluxes has not yet been experimentally elucidated. The authors interpreted the residual flux as representing the ending states of transient phenomena after tripping; and tested this interpretation experimentally. In the authors' interpretation; a three-phase balanced transient phenomenon of the voltage; current; and core flux occurs immediately after the transformer is tripped at the time top0; and it continues until time t op1. The true nature of the residual flux is the core fluxes φa(t op 1); φb(t op 1); φc(t op 1) at top1. Furthermore; these residual fluxes as well as the voltages and currents during the transient interval are practically three-phase balanced; so that they can be expressed as three-phase balanced equilateral triangular phasors. The core flux values and waveforms cannot be directly measured but they can be digitally generated as the integrals of the voltage waveform. Thus a test of the residual flux under the above interpretation can be performed indirectly by preparing (1) measured voltage waveforms just after transformer tripping; (2) flux waveforms mathematically generated by voltage integration just after tripping; and (3) measured transient inrush current i rush a; i rush b; i rush c; occurring immediately after the transformer is re-energized at time θcl; and then comparing these three data as characteristics in the 3-D coordinates of [θ op 0; θ; cl; i rush ] and of [θ op 1; i rush ]. Verification tests were performed utilizing a simulation test circuit in which large numbers of on-off switching tests of a transformer were conducted. The test results clearly indicated that the inrush current reaches its maximum whenever θcl is in antiphase with θop1 (instead of θop0); and reaches its minimum whenever θcl is in phase with θop1. These test results confirmed the authors' interpretation of the true nature of the transient phenomena and the residual flux after tripping. The test results suggest essential algorithms for inrush current restraining control in order to appropriately restrain inrush current phenomena. Field test results at a 66-kV wind power station where commercial equipment based on the above described theory and method were in service are also presented. © 2014 Wiley Periodicals; Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [1] Experimental Study of Transformer Residual Flux and the Method of Restraining Inrush Current
    Hase, Yoshihide
    Kamesawa, Tomoyuki
    Inoue, Shinji
    Yamamura, Shunichiro
    ELECTRICAL ENGINEERING IN JAPAN, 2014, 188 (04) : 54 - 67
  • [2] Experimental study of transformer residual flux and the method of restraining inrush current
    Hase, Yoshihide
    Kamesawa, Tomoyuki
    Inoue, Shinji
    Yamamura, Shunichiro
    IEEJ Transactions on Power and Energy, 2013, 133 (07) : 606 - 615
  • [3] A Method for Calculation of the Inrush Current in Single Phase Transformer including the Residual Flux
    Waindok, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (5B): : 194 - 201
  • [4] The Inrush current analysis and restraining method of Energizing No-load Transformer
    Chen, Ning
    Wang, Chuanyong
    Zhang, Jian
    Yang, Fengwen
    Chen, Yuchen
    Hong, Wei
    2016 3RD INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2016, : 204 - 207
  • [5] Development of a transformer magnetizing circuit model for inrush current and residual flux calculations
    Yonezawa, Rikido
    Noda, Taku
    Suzuki, Naoto
    Nagashima, Hiroshi
    Nomiyama, Fumitoshi
    Yamaguchi, Norikazu
    Honma, Hitoshi
    Kitamura, Seishou
    IEEJ Transactions on Power and Energy, 2014, 134 (09) : 749 - 758
  • [6] The Application of Inrush Current Restraining Technology in Transformer Economic Operation
    Yang Yong
    Liu Zhizhen
    Cong Min
    Qi Guozheng
    Hu Gang
    2015 18TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2015, : 1386 - 1389
  • [7] Accurate transformer inrush current analysis by controlling closing instant and residual flux
    Sung, Byung Chul
    Kim, Seongil
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [8] Transformer Inrush Current Restraining Scheme Based on Closing Voltage Amplitude Controlling Method
    Wang Weixu
    Cong Wei
    Sheng Yaru
    Xiao Jing
    Cao Jianmei
    Hao Qingshui
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 727 - 731
  • [9] Influence of circuit breaker operation upon transformer's residual flux and inrush current
    Horiszny, Jacek
    PRZEGLAD ELEKTROTECHNICZNY, 2007, 83 (11): : 208 - 211
  • [10] Analysis of the residual flux influence on inrush current and electromagnetic force in large power transformer
    Ge, Wenqi
    Zhao, Jianhai
    Wang, Youhua
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2426 - 2429