Experimental study of transformer residual flux and the method of restraining inrush current

被引:0
|
作者
机构
[1] Hase, Yoshihide
[2] Kamesawa, Tomoyuki
[3] Inoue, Shinji
[4] Yamamura, Shunichiro
来源
| 1600年 / John Wiley and Sons Inc卷 / 188期
关键词
SUMMARY Whenever a power transformer in a no-load condition is manually tripped; a residual flux appears in the transformer core; which causes an inrush current when the transformer is later re-energized. However; the true nature of residual fluxes has not yet been experimentally elucidated. The authors interpreted the residual flux as representing the ending states of transient phenomena after tripping; and tested this interpretation experimentally. In the authors' interpretation; a three-phase balanced transient phenomenon of the voltage; current; and core flux occurs immediately after the transformer is tripped at the time top0; and it continues until time t op1. The true nature of the residual flux is the core fluxes φa(t op 1); φb(t op 1); φc(t op 1) at top1. Furthermore; these residual fluxes as well as the voltages and currents during the transient interval are practically three-phase balanced; so that they can be expressed as three-phase balanced equilateral triangular phasors. The core flux values and waveforms cannot be directly measured but they can be digitally generated as the integrals of the voltage waveform. Thus a test of the residual flux under the above interpretation can be performed indirectly by preparing (1) measured voltage waveforms just after transformer tripping; (2) flux waveforms mathematically generated by voltage integration just after tripping; and (3) measured transient inrush current i rush a; i rush b; i rush c; occurring immediately after the transformer is re-energized at time θcl; and then comparing these three data as characteristics in the 3-D coordinates of [θ op 0; θ; cl; i rush ] and of [θ op 1; i rush ]. Verification tests were performed utilizing a simulation test circuit in which large numbers of on-off switching tests of a transformer were conducted. The test results clearly indicated that the inrush current reaches its maximum whenever θcl is in antiphase with θop1 (instead of θop0); and reaches its minimum whenever θcl is in phase with θop1. These test results confirmed the authors' interpretation of the true nature of the transient phenomena and the residual flux after tripping. The test results suggest essential algorithms for inrush current restraining control in order to appropriately restrain inrush current phenomena. Field test results at a 66-kV wind power station where commercial equipment based on the above described theory and method were in service are also presented. © 2014 Wiley Periodicals; Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [21] Experimental Study on Controlled Unloaded Transformer Switching Considering Residual Flux
    Chen Chuanjiang
    Fang Chun-en
    Xiao Yang
    Li Wei
    Zhang Bi-de
    Ren Xiao
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 527 - 530
  • [22] New magnetizing inrush restraining algorithm for power transformer protection
    Kulidjian, A
    Kasztenny, B
    Campbell, B
    SEVENTH INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN POWER SYSTEM PROTECTION, 2001, (479): : 181 - 184
  • [23] Transformer Inrush - Harmonics in the Current
    Jiri, Bermann
    Martin, Prochazka
    PROCEEDINGS OF THE 2018 19TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2018, : 130 - 133
  • [24] POWER TRANSFORMER INRUSH CURRENT
    GEISER, DT
    QST, 1984, 68 (12) : 50 - 51
  • [25] Inrush Current of Superconducting Transformer
    Wojtasiewicz, G.
    Komarzyniec, G.
    Janowski, T.
    Kozak, S.
    Kozak, J.
    Majka, M.
    Kondratowicz-Kucewicz, B.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [26] The Inrush Current Eliminator of Transformer
    Wu, Li-Cheng
    Liu, Chih-Wen
    PROCEEDINGS OF THE 2011 2ND INTERNATIONAL CONGRESS ON COMPUTER APPLICATIONS AND COMPUTATIONAL SCIENCE, VOL 1, 2012, 144 : 411 - 419
  • [27] A Method for Identification of Transformer Inrush Current Based on Box Dimension
    Gong, Maofa
    Zheng, Ran
    Hou, Linyuan
    Wei, Jingyu
    Wu, Na
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2017, 2017
  • [28] Identification Method of Transformer Inrush Current Based on Skewness Coefficient
    Hu S.
    Jiang Y.
    Huang C.
    Jiang, Yaqun (yaqunjiang@21cn.com), 1954, Power System Technology Press (42): : 1954 - 1959
  • [29] Reduction of Inrush Current for Transformer Using Sequential Switching Method
    Gohil, Ketan
    Patel, Jatinkumar
    Parekh, Chirag
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 3942 - 3948
  • [30] Flux Error Function Based Controlled Switching Method for Minimizing Inrush Current in 3-Phase Transformer
    Pachore, Parvraj
    Gupta, Yugal
    Anand, Sandeep
    Sarkar, Subrata
    Mathur, Paresh
    Singh, Pushpendra Kumar
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (02) : 870 - 879