Stress distribution of the variable dynamic loading in the dental implant: A three-dimensional finite element analysis

被引:8
|
作者
Djebbar N. [1 ,2 ]
Serier B. [1 ]
Bouiadjra B.B. [1 ]
机构
[1] Department of Mechanical Engineering, University of HassibaBenbouali, Essalem City, No 19 National Road, Chlef
[2] LMPM, Department of Mechanical Engineering, University of SidiBel Abbes, BP 89, Ben M'hidicity, SidiBel Abbes
来源
| 1600年 / Trans Tech Publications Ltd卷 / 31期
关键词
Biomechanics; Bone; Dynamic loading; Finite element analysis;
D O I
10.4028/www.scientific.net/JBBBE.31.44
中图分类号
学科分类号
摘要
Stable osseointegration between implant threads and the surrounding marginal bone, provides the mechanical base of an implant for daily chewing activity. The contact area of implantbone interfaces and the concentrated stresses, on the marginal bones are principal concerns of implant designers. In this work, we numerically analyze by the finite element method the distribution of the equivalent stress and their level in the bone, the most fragile element of the dental prosthesis. Each set of the model contained a crown, framework, abutment, implant and bone, subjected to variable dynamic loading according to time. © 2017 Trans Tech Publications, Switzerland.
引用
收藏
页码:44 / 52
页数:8
相关论文
共 50 条
  • [21] A three-dimensional finite element analysis of osseointegrated implant on stress distribution of different abutment designs and fixture diameters
    Kwon, HB
    Kim, YS
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1267 - 1267
  • [22] Three-dimensional finite element analysis of stress distribution in retention screws of different crown-implant ratios
    Moraes, S. L. D.
    Pellizzer, E. P.
    Verri, F. R.
    Santiago, J. F., Jr.
    Silva, J. V. L.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (07) : 689 - 696
  • [23] Three-Dimensional Nonlinear Finite Element Analysis and Microcomputed Tomography Evaluation of Microgap Formation in a Dental Implant Under Oblique Loading
    Joern, Daniela
    Kohorst, Philipp
    Besdo, Silke
    Borchers, Lothar
    Stiesch, Meike
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) : E32 - E42
  • [24] Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis
    Geramizadeh, Maryam
    Katoozian, Hamidreza
    Amid, Reza
    Kadkhodazadeh, Mahdi
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2018, 44 (02) : 59 - 65
  • [25] Three-dimensional finite element analysis of the effects of implant diameter and photofunctionalization on peri-implant stress
    Ohyama, Tetsuo
    Yasuda, Hiroyasu
    Shibuya, Norio
    Tadokoro, Satomi
    Nakabayashi, Shinya
    Namaki, Shunsuke
    Hara, Yaeko
    Ogawa, Takahiro
    Ishigami, Tomohiko
    JOURNAL OF ORAL SCIENCE, 2017, 59 (02) : 273 - 278
  • [26] Three-dimensional finite element analysis of platform switched implant
    Moon, Se-Young
    Lim, Young-Jun
    Kim, Myung-Joo
    Kwon, Ho-Beom
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (01): : 31 - 37
  • [27] A three-dimensional finite element analysis with various implant designs
    Yoo, Dong-Ki
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    Lim, Young-Jun
    Kim, Sung-Hun
    Han, Chong-Hyun
    ASBM7: ADVANCED BIOMATERIALS VII, 2007, 342-343 : 885 - +
  • [28] Influence of inhomogeneous dental posts on stress distribution in tooth root and interfaces: Three-dimensional finite element analysis
    Mahmoudi, Mojtaba
    Saidi, Ali Reza
    Amini, Parviz
    Hashemipour, Maryam Alsadat
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (06): : 742 - 751
  • [29] Modeling of Dental Implant Osseointegration Progress by Three-Dimensional Finite Element Method
    Roatesi, Iulia
    Roatesi, Simona
    APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [30] Finite Element Analysis of Stress Distribution in Immediately Loaded Dental Implant
    Bahrami, Babak
    Ghalichi, Farzan
    Mirzakouchaki, Behnam
    Ashtiani, Mohammed N.
    Marghoub, Arsalan
    2012 19TH IRANIAN CONFERENCE OF BIOMEDICAL ENGINEERING (ICBME), 2012, : 154 - 157