Process optimization in glass wafer cut-off grinding - Cut-off grinding with direct substrate fixation on cutting foils to save costs and time

被引:0
|
作者
Jahnel K. [1 ]
Maier W. [2 ]
Wilhelm D.P. [1 ]
Hähnel S. [1 ]
Grunwald T. [1 ]
Bergs T. [1 ]
机构
[1] Fraunhofer-Institut für Produktionstechnologie IPT, Steinbachstr. 17, Aachen
[2] Ingeneric GmbH, Zum Carl-Alexander-Park 7, Baesweile
来源
WT Werkstattstechnik | 2023年 / 113卷 / 06期
关键词
Fertigungstechnik; Schleifen; Spanntechnik;
D O I
10.37544/1436-4980-2023-06-41
中图分类号
学科分类号
摘要
Fast Axis Collimators (FAC) are essential optical elements for diode laser systems. The increasing number of damages occurring in the current process of cut-off grinding with downstream cleaning of FAC optics made of pressed anti-reflective coated glass wafers limits the use of optics in high-power applications. Using cutting film for substrate fixation during cut-off grinding of FAC optics allows for defect-free cutting and clean release from the cutting film while saving costs and production time. © 2023, VDI Fachmedien GmBH & Co. KG. All rights reserved.
引用
收藏
页码:249 / 254
页数:5
相关论文
共 36 条
  • [31] Slotted-electrical discharge diamond cut-off grinding of Al/SiC/B4C hybrid metal matrix composite
    Yadav, Ravindra Nath
    Yadava, Vinod
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (01) : 309 - 316
  • [32] Experimental investigation of electrochemical cut-off grinding for Inconel-718 and comparative study with Ti-6Al-4V alloy
    Yadav, Sunil Kumar
    Yadav, Sanjeev Kumar Singh
    ADVANCES IN MATERIALS AND PROCESSING TECHNOLOGIES, 2024, 10 (04) : 3358 - 3373
  • [33] Lupus Anticoagulant Diagnosis in Activated Partial Thromboplastin Time Mixing Test: Optimization of the Index of Circulating Anticoagulant Cut-Off Value
    Kumano, Osamu
    Ieko, Masahiro
    Naito, Sumiyoshi
    Yoshida, Mika
    Takahashi, Nobuhiko
    Suzuki, Takeshi
    Aoki, Takashi
    CLINICAL LABORATORY, 2014, 60 (12) : 2115 - 2118
  • [34] Signal to cut-off (S/CO) ratio and detection of HCV genotype 1 by real-time PCR one-step method: is there any direct relationship?
    Albertoni, Guilherme
    Arnoni, C. P.
    Araujo, P. R. B.
    Carvalho, F. O.
    Barreto, J. A.
    BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2010, 14 (02): : 147 - 152
  • [35] Real-Time Monitoring of Results During First Year of Dutch Colorectal Cancer Screening Program and Optimization by Altering Fecal Immunochemical Test Cut-Off Levels
    Toes-Zoutendijk, Esther
    van Leerdam, Monique E.
    Dekker, Evelien
    van Hees, Frank
    Penning, Corine
    Nagtegaal, Iris
    van der Meulen, Miriam P.
    van Vuuren, Anneke J.
    Kuipers, Ernst J.
    Bonfrer, Johannes M. G.
    Biermann, Katharina
    Thomeer, Maarten G. J.
    van Veldhuizen, Harriet
    Kroep, Sonja
    van Ballegooijen, Marjolein
    Meijer, Gerrit A.
    de Koning, Harry J.
    Spaander, Manon C. W.
    Lansdorp-Vogelaar, Iris
    GASTROENTEROLOGY, 2017, 152 (04) : 767 - +
  • [36] UPLC-MS/MS method for the simultaneous quantification of caffeine and illicit psychoactive drugs in hair using a single-step high-speed grinding extraction - Insights into a cut-off value for caffeine abuse
    Jiang, Shan
    Zhong, Yuling
    Qiao, Hongwei
    Di, Bin
    Chen, Jie
    Su, Mengxiang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 209