Compact Electron Paramagnetic Resonance on a Chip Spectrometer Using a Single Sided Permanent Magnet

被引:1
|
作者
Segantini, Michele [1 ]
Marcozzi, Gianluca [1 ]
Elrifai, Tarek [2 ]
Shabratova, Ekaterina [1 ,3 ]
Hoeflich, Katja [3 ]
Deaconeasa, Mihaela [4 ]
Niemann, Volker [4 ]
Pietig, Rainer [4 ]
McPeak, Joseph E. [1 ]
Anders, Jens [2 ,5 ,6 ]
Naydenov, Boris [1 ]
Lips, Klaus [1 ,7 ]
机构
[1] Helmholtz Zentum Berlin Mat & Energie GmbH, D-14109 Berlin, Germany
[2] Univ Stuttgart, Inst Smart Sensors, D-70569 Stuttgart, Germany
[3] Leibniz Inst Hochstfrequenztechn, Ferdinand Braun Inst GGmbH, D-12489 Berlin, Germany
[4] Bruker BioSpin GmbH, D-76275 Ettlingen, Germany
[5] Ctr Integrated Quantum Sci & Technol, D-70569 Stuttgart, Germany
[6] Ctr Integrated Quantum Sci & Technol, D-70569 Ulm, Germany
[7] Free Univ Berlin, Berlin Joint EPR Lab, Fachbereich Phys, D-14195 Berlin, Germany
来源
ACS SENSORS | 2024年 / 9卷 / 10期
关键词
EPR; EPRoC; single side permanentmagnet; spin counting; in situ; in vivo; operando; molecular tumbling; OXIDATIVE STABILITY; RELAXATION-TIMES; OLIVE OILS; EPR; SPECTROSCOPY;
D O I
10.1021/acssensors.4c00788
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electron paramagnetic resonance (EPR) spectroscopy provides information about the physical and chemical properties of materials by detecting paramagnetic states. Conventional EPR measurements are performed in high Q resonator using large electromagnets which limits the available space for operando experiments. Here we present a solution toward a portable EPR sensor based on the combination of the EPR-on-a-Chip (EPRoC) and a single-sided permanent magnet. This device can be placed directly into the sample environment (i.e., catalytic reaction vessels, ultrahigh vacuum deposition chambers, aqueous environments, etc.) to conduct in situ and operando measurements. The EPRoC reported herein is comprised of an array of 14 voltage-controlled oscillator (VCO) coils oscillating at 7 GHz. By using a single grain of crystalline BDPA, EPR measurements at different positions of the magnet with respect to the VCO array were performed. It was possible to create a 2D spatial map of a 1.5 mm x 5 mm region of the magnetic field with 50 mu m resolution. This allowed for the determination of the magnetic field intensity and homogeneity, which are found to be 254.69 mT and 700 ppm, respectively. The magnetic field was mapped also along the vertical direction using a thin film a-Si layer. The EPRoC and permanent magnet were combined to form a miniaturized EPR spectrometer to perform experiments on tempol (4-hydroxy-2,2,6,6-teramethylpiperidin-1-oxyl) dissolved in an 80% glycerol and 20% water solution. It was possible to determine the molecular tumbling correlation time and to establish a calibration procedure to quantify the number of spins within the sample.
引用
收藏
页码:5099 / 5108
页数:10
相关论文
共 50 条
  • [31] Tabletop 700 MHz electron paramagnetic resonance imaging spectrometer
    Buchanan, Laura A.
    Rinard, George A.
    Quine, Richard W.
    Eaton, Sandra S.
    Eaton, Gareth R.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2018, 48B (02)
  • [32] X-band pulsed electron paramagnetic resonance spectrometer
    Duchiewicz, J
    Dobrucki, AL
    Francik, A
    Czoch, R
    Sadowski, A
    Liber, A
    MIKON-98: 12TH INTERNATIONAL CONFERENCE ON MICROWAVES & RADAR, VOLS 1-4, 1998, : 643 - 647
  • [33] L-Band Electron Paramagnetic Resonance (EPR) Spectrometer
    Idzkowski, B.
    Duchiewicz, J.
    Dobrucki, A.
    Duchiewicz, T.
    Francik, A.
    Sadowski, S.
    Walesiak, S.
    Kutynia, A.
    Blaszczyk, J.
    18TH INTERNATIONAL CONFERENCE ON MICROWAVES, RADAR AND WIRELESS COMMUNICATIONS (MIKON-2010), VOL 1 AND VOL 2, 2010,
  • [34] MILLIMETER RANGE RESONATOR FOR ELECTRON-PARAMAGNETIC RESONANCE SPECTROMETER
    LUKIN, SN
    NEMCHENK.ED
    ORANSKII, LG
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1974, (04): : 116 - 117
  • [35] Thermal analysis of a single sided axial flux Permanent Magnet Motor
    Vilar, ZW
    Patterson, D
    Dougal, RA
    IECON 2005: THIRTY-FIRST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2005, : 2570 - 2574
  • [36] A Single-Chip Electron Paramagnetic Resonance Transceiver in 0.13-μm SiGe BiCMOS
    Yang, Xuebei
    Babakhani, Aydin
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (11) : 3727 - 3735
  • [37] Comparative Investigation of Single-sided and Double-sided Permanent Magnet Linear Motor
    Lu, Qinfen
    Cheng, Chuanying
    Zhang, Xinmin
    Huang, Liren
    Yang, Zilong
    Ma, Dayong
    Ye, Yunyue
    Fang, Youtong
    2012 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2012), 2012,
  • [38] Comparative Study of Permanent Magnet Machines with Single-Sided and Dual-Sided Magnets
    Li, Ya
    Yang, Hui
    Lin, Heyun
    Wang, Keyi
    Lyu, Shukang
    2018 XIII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2018, : 2430 - 2436
  • [39] In situ electron paramagnetic resonance spectroscopy using single nanodiamond sensors
    Qin, Zhuoyang
    Wang, Zhecheng
    Kong, Fei
    Su, Jia
    Huang, Zhehua
    Zhao, Pengju
    Chen, Sanyou
    Zhang, Qi
    Shi, Fazhan
    Du, Jiangfeng
    NATURE COMMUNICATIONS, 2023, 14 (01)
  • [40] In situ electron paramagnetic resonance spectroscopy using single nanodiamond sensors
    Zhuoyang Qin
    Zhecheng Wang
    Fei Kong
    Jia Su
    Zhehua Huang
    Pengju Zhao
    Sanyou Chen
    Qi Zhang
    Fazhan Shi
    Jiangfeng Du
    Nature Communications, 14