Dynamic characteristic analysis of electromagnetic field of ABS solenoid valve

被引:0
|
作者
Zhang, Peng [1 ]
Yang, Yi [1 ]
Dong, Xinhua [1 ]
Sheng, Deke [1 ]
Hu, Suxi [1 ]
机构
[1] School of Mechanical Electronic and Information Engineering, China University of Mining and Technology, Beijing,100083, China
来源
Paper Asia | 2018年 / COMPENDIUM 2期
关键词
Solenoid valves - Solenoids - Anti-lock braking systems;
D O I
暂无
中图分类号
学科分类号
摘要
The dynamic characteristics of the automobile anti-lock braking system (ABS) solenoid valve plays an vital role in the ABS performance, which mainly depends on the dynamic response characteristics of the electromagnetic field of the solenoid valve in addition to the structural parameters of the solenoid valve and relevant material properties. Considering the nonlinear magnetic properties of material and the influence of the main working gap, the finite element model of the solenoid valve has been established using software Ansoft Maxwell. And many factors that can affect the solenoid valve response characteristics have been simulated. The simulation results indicate that we can improve the response time of the solenoid valve by appropriately increasing the excitation voltage or by reducing the working gap length or the non-working gap length. And the design of solenoid valve should select the optimal coil number of turns by calculating. It should be pointed out that the coil number of turns is not as small as possible, and the moving iron maximum speed will reduce if the coil number of turns is too small. © 2018 SHPMedia Sdn Bhd. All rights reserved.
引用
收藏
页码:100 / 103
相关论文
共 50 条
  • [41] Research on dynamic characteristics of solenoid directional valve with random vibration
    Yang Z.
    Bao J.
    Zhou L.
    1600, Huazhong University of Science and Technology (44): : 13 - 17and51
  • [42] Dynamic displacement response characteristics of a solenoid actuator for electromagnetic separation
    Lu, Jianbo
    Li, Yong
    Xi, Junbin
    Liu, Hongliang
    SENSORS, MECHATRONICS AND AUTOMATION, 2014, 511-512 : 366 - 369
  • [43] Modeling and Dynamic Analysis on the Direct Operating Solenoid Valve for Improving the Performance of the Shifting Control System
    Xu, Xiangyang
    Han, Xiao
    Liu, Yanfang
    Liu, Yanjing
    Liu, Yang
    APPLIED SCIENCES-BASEL, 2017, 7 (12):
  • [44] MAGNETIC FIELD ANALYSIS OF ELECTROMAGNETIC VALVE TAKING HYSTERESIS INTO ACCOUNT
    Zhang ShengchangZhong TingxiuXu YangzengShi GuanglinSchool of Mechanical Engineering
    Chinese Journal of Mechanical Engineering, 2003, (03) : 245 - 247
  • [45] Dynamic characteristic of water valve in HVAC
    Jun, C
    Jiang, N
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 1142 - 1148
  • [46] Dynamic Characteristic Analysis of Monostable Torque Motor Valve of Bipropellant Thrusters
    Guan Changbin
    Chen Jun
    Jiao Zongxia
    PROCEEDINGS OF 2015 INTERNATIONAL CONFERENCE ON FLUID POWER AND MECHATRONICS - FPM 2015, 2015, : 332 - 336
  • [47] Dynamic characteristic analysis of replenishing/leaking parallel valve control systems
    Ding, Haigang
    Zhao, Jiyun
    AUTOMATIKA, 2017, 58 (02) : 182 - 194
  • [48] A Fast Solving Technique for Dynamic Characteristic Analysis of Electromagnetic Repulsive System
    Li, Wei
    Jeong, Young Woo
    Koh, Chang Seop
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 324 - +
  • [49] Minimization of Electromagnetic Forces on Solenoid Wall in External Magnetic Field
    Shneerson, G. A.
    TECHNICAL PHYSICS LETTERS, 2011, 37 (10) : 914 - 916
  • [50] Minimization of electromagnetic forces on solenoid wall in external magnetic field
    G. A. Shneerson
    Technical Physics Letters, 2011, 37 : 914 - 916