Bearing Capacity of Composite Joints of U-shaped Steel Composite Beams and Concrete-filled Square Steel Tubular Columns Based on Channel Steel Connection

被引:0
|
作者
Zhang Z. [1 ]
Mao G. [1 ]
He R. [1 ]
Xiao A. [1 ,2 ]
Liu Z. [1 ,3 ]
机构
[1] College of Civil Engineering, Hunan City University, Yiyang, 410003, Hunan
[2] Zhongmin Zhuyou Technology Co. Ltd, Changsha
[3] Department of Civil Engineering, University of Auckland, Auckland
关键词
bearing capacity; Channel steel penetration connection; concrete-filled square steel tubular column (CFSTBC); U-shaped steel composite beam (USCB);
D O I
10.25103/jestr.144.06
中图分类号
学科分类号
摘要
Traditional beam-column connection structures fail to meet design requirements of hidden beams and columns in the application of composite frames formed by U-shaped steel composite beams (USCBs) and concrete-filled square steel tubular columns (CFSTBCs) to residential buildings. Therefore, a novel beam-column connection structure of U-shaped steel composite beams and concrete-filled steel tubular columns based on channel steel connections was proposed in this study. An experimental study and finite element simulation analysis of the joint performance of the novel composite frame side joint specimen under monotonic load were carried out. Failure mode and bearing capacity of joints under negative bending moment were discussed based on the experimental investigation of two full-scale joints. The influence of beam section height, width-thickness ratio of column, and axial compression ratio on the bearing capacity of joints was explored by analyzing parameters of the finite element model. Results demonstrate that failure form of the joint is tensile crack of concrete floor at flange of core area of the joint under the action of negative bending moment, ductility coefficient of the joint is greater than 2.0, and bearing and ductility performance is excellent. Beam section height significantly influences the bearing capacity of joints, while the width-thickness ratio of the steel tube column slightly influences the bearing capacity of joints when the requirement of “strong columns and weak beams” is met. The bearing capacity of the joint is minimally affected by the change of axial compression ratio when the axial compression ratio of the column is less than or equal to 0.6. However, the bearing capacity is significantly reduced with the increase of the axial compression ratio when the axial compression ratio is greater than 0.6. This study can provide a theoretical basis for the engineering application and popularization of the novel composite frame beam-column connection structure. © 2021 School of Science, IHU. All Rights Reserved.
引用
收藏
页码:40 / 52
页数:12
相关论文
共 50 条
  • [41] COMPRESSIVE BEARING CAPACITY OF COMPOSITE TALL PIER COMPOSED OF CONCRETE-FILLED STEEL TUBULAR COLUMN AND SOFT STEEL PLATE
    Cai Z.-H.
    Zhuo W.-D.
    Wang Z.-J.
    Huang X.-Y.
    Liu Q.-J.
    Gongcheng Lixue/Engineering Mechanics, 2024, (03): : 150 - 162
  • [42] Numerical Analysis and Axial Bearing Capacity of Composite Columns with Recycled Aggregate Concrete-Filled Steel Tube and Profile Steel
    Dong, Jing
    Ma, Hui
    Liu, Yunhe
    Guo, Tingting
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (05) : 3581 - 3598
  • [43] Numerical Analysis and Axial Bearing Capacity of Composite Columns with Recycled Aggregate Concrete-Filled Steel Tube and Profile Steel
    Jing Dong
    Hui Ma
    Yunhe Liu
    Tingting Guo
    Arabian Journal for Science and Engineering, 2020, 45 : 3581 - 3598
  • [44] APPLICATION OF OPENSEES ON SIMULATING OF STEEL BEAM TO CONCRETE-FILLED STEEL TUBULAR COLUMNS JOINTS
    Qu, H.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON INSPECTION APPRAISAL REPAIRS AND MAINTENANCE OF STRUCTURES, VOLS 1 AND 2, 2010, : 921 - 924
  • [45] Deformation calculation of composite beams with concrete and prestressed U-shaped steel
    Yu, Jian-Jun
    Wang, Lian-Guang
    Huo, Jun-Hua
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2012, 44 (SUPPL.1): : 218 - 221
  • [46] Seismic Analysis and Design of Composite Steel/Concrete Building Structures Involving Concrete-Filled Steel Tubular Columns
    Skalomenos, Konstantinos A.
    Hatzigeorgiou, George D.
    Beskos, Dimitri E.
    RECENT ADVANCES IN EARTHQUAKE ENGINEERING IN EUROPE, 2018, 46 : 387 - 411
  • [47] The Horizontal Bearing Capacity of Composite Concrete-Filled Steel Tube Piles
    Dong, Yunxiu
    Feng, Zhongju
    Hu, Haibo
    He, Jingbin
    Zhang, Qilang
    Wang, Fuchun
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [48] Composite action of concrete-filled double circular steel tubular stub columns
    Wang, Liping
    Cao, Xing-xing
    Ding, Fa-xing
    Luo, Liang
    Sun, Yi
    Liu, Xue-mei
    Su, Hui-lin
    STEEL AND COMPOSITE STRUCTURES, 2018, 29 (01): : 77 - 90
  • [49] Composite dowels as load introduction devices in concrete-filled steel tubular columns
    Cardoso, Hermano de Sousa
    Aguiar, Otavio Prates
    Caldas, Rodrigo Barreto
    Fakury, Ricardo Hallal
    ENGINEERING STRUCTURES, 2020, 219 (219)
  • [50] Behaviour of FRP-strengthened concrete-filled steel tubular composite columns
    College of Civil Engineering, Fuzhou University, Fujian, Fuzhou 350108, China
    不详
    Harbin Gongye Daxue Xuebao, 1600, SUPPL. 2 (18-21):