Bearing Capacity of Composite Joints of U-shaped Steel Composite Beams and Concrete-filled Square Steel Tubular Columns Based on Channel Steel Connection

被引:0
|
作者
Zhang Z. [1 ]
Mao G. [1 ]
He R. [1 ]
Xiao A. [1 ,2 ]
Liu Z. [1 ,3 ]
机构
[1] College of Civil Engineering, Hunan City University, Yiyang, 410003, Hunan
[2] Zhongmin Zhuyou Technology Co. Ltd, Changsha
[3] Department of Civil Engineering, University of Auckland, Auckland
关键词
bearing capacity; Channel steel penetration connection; concrete-filled square steel tubular column (CFSTBC); U-shaped steel composite beam (USCB);
D O I
10.25103/jestr.144.06
中图分类号
学科分类号
摘要
Traditional beam-column connection structures fail to meet design requirements of hidden beams and columns in the application of composite frames formed by U-shaped steel composite beams (USCBs) and concrete-filled square steel tubular columns (CFSTBCs) to residential buildings. Therefore, a novel beam-column connection structure of U-shaped steel composite beams and concrete-filled steel tubular columns based on channel steel connections was proposed in this study. An experimental study and finite element simulation analysis of the joint performance of the novel composite frame side joint specimen under monotonic load were carried out. Failure mode and bearing capacity of joints under negative bending moment were discussed based on the experimental investigation of two full-scale joints. The influence of beam section height, width-thickness ratio of column, and axial compression ratio on the bearing capacity of joints was explored by analyzing parameters of the finite element model. Results demonstrate that failure form of the joint is tensile crack of concrete floor at flange of core area of the joint under the action of negative bending moment, ductility coefficient of the joint is greater than 2.0, and bearing and ductility performance is excellent. Beam section height significantly influences the bearing capacity of joints, while the width-thickness ratio of the steel tube column slightly influences the bearing capacity of joints when the requirement of “strong columns and weak beams” is met. The bearing capacity of the joint is minimally affected by the change of axial compression ratio when the axial compression ratio of the column is less than or equal to 0.6. However, the bearing capacity is significantly reduced with the increase of the axial compression ratio when the axial compression ratio is greater than 0.6. This study can provide a theoretical basis for the engineering application and popularization of the novel composite frame beam-column connection structure. © 2021 School of Science, IHU. All Rights Reserved.
引用
收藏
页码:40 / 52
页数:12
相关论文
共 50 条
  • [31] Bearing capacity of axially loaded stirrup confined concrete-filled square steel tubular stub columns
    Gong Y.
    Fu L.
    Ding F.
    Yu Z.
    Li G.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2016, 37 : 239 - 244
  • [32] Initial stiffness and moment capacity assessment of stainless steel composite bolted joints with concrete-filled circular tubular columns
    Wang, Jia
    Uy, Brian
    Li, Dongxu
    STEEL AND COMPOSITE STRUCTURES, 2019, 33 (05): : 681 - 697
  • [33] Bearing capacity of composite columns reinforced by concrete filled steel tube
    韦建刚
    ZHU Pu
    CHEN Bao-chun
    Journal of Chongqing University(English Edition), 2013, 12 (01) : 27 - 34
  • [34] Seismic behavior of composite shear walls with boundary columns using rectangular and U-shaped concrete-filled steel tubes
    Wang, Guo-Jue
    Jiang, Shi-Yong
    Hou, Quan-Sheng
    Zhu, Li-Min
    Tian, Chun-Yu
    JOURNAL OF BUILDING ENGINEERING, 2023, 73
  • [35] Design method for connections between concrete-filled square tubular columns and steel beams
    Lu, Xi-Lin
    Li, Xue-Ping
    Yu, Yong
    Tongji Daxue Xuebao/Journal of Tongji University, 2002, 30 (01): : 1 - 5
  • [36] Seismic behavior of diaphragm-through connections of concrete-filled square steel tubular columns and H-shaped steel beams
    Rong B.
    Chen Z.
    Fafitis A.
    Miao J.
    Transactions of Tianjin University, 2013, 19 (3) : 195 - 201
  • [37] Seismic Behavior of Diaphragm-Through Connections of Concrete-Filled Square Steel Tubular Columns and H-Shaped Steel Beams
    荣彬
    陈志华
    Apostolos Fafitis
    苗纪奎
    Transactions of Tianjin University, 2013, (03) : 195 - 201
  • [38] Temperatures in unprotected joints between steel beams and concrete-filled tubular columns in fire
    Ding, J.
    Wang, Y. C.
    FIRE SAFETY JOURNAL, 2009, 44 (01) : 16 - 32
  • [39] Shear capacity of concrete-filled steel plate composite coupling beams
    Hu, Hong-Song
    Nie, Jian-Guo
    Wang, Yu-Hang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 118 : 76 - 90
  • [40] Seismic Behavior of Diaphragm-Through Connections of Concrete-Filled Square Steel Tubular Columns and H-Shaped Steel Beams
    荣彬
    陈志华
    Apostolos Fafitis
    苗纪奎
    Transactions of Tianjin University, 2013, 19 (03) : 195 - 201