A Study on the Effect of Distributed Generation on Short-circuit Current and Voltage: Validation and Case Studies

被引:0
|
作者
Kim I. [1 ]
机构
[1] Dept. of Electrical Engineering, Inha University
关键词
current injection method; inverter-based distributed generation (IBDG); overvoltage; Short-circuit current;
D O I
10.5370/KIEE.2022.71.12.1848
中图分类号
学科分类号
摘要
Distributed generation (DG) resources defined as small, medium, or large grid-connected or stand-alone electric energy sources can show many advantages such as improving reliability (e.g., decreasing the failure frequency and duration), the emergency supply of power (e.g., islanding operation), or peak power reductions (e.g., peak demand reduction at peak hours). However, these DG resources are in nature an electric energy source, so they can affect the short-circuit current of the system to which they are connected. Thus, the objective of this study is to present several case studies on the effect of DG on a change in short-circuit current and voltage. For this purpose, Part 1 presented a method of accurately calculating short-circuit current caused by DG working as a current source, which was defined as the current injection method. As an extended study, Part 2 of this study presents an example of calculating short-circuit current and voltage in detail. As a result of case studies, this study verifies the proposed method and examines the effect of DG on short-circuit current and voltage after a single line-to-ground fault. The case studies show that as the capacity of DG increases, DG can also increase the short-circuit current, but with a slight change rate (e.g., up to 17.44% in the simple 5-bus power system), and DG may cause a slight overvoltage problem during or after the fault. Copyright © The Korean Institute of Electrical Engineers.
引用
收藏
页码:1848 / 1856
页数:8
相关论文
共 50 条
  • [41] PRESSURE JUMP RELAXATION KINETICS OF FROG SKIN OPEN CIRCUIT VOLTAGE AND SHORT-CIRCUIT CURRENT
    SEGAL, JR
    BIOCHIMICA ET BIOPHYSICA ACTA, 1977, 471 (03) : 453 - 465
  • [42] Effect of TCVR controlled voltage on short-circuit calculations in case of ground fault in the Algerian network
    Zellagui, Mohamed
    Hassan, Heba Ahmed
    Chaghi, Abdelaziz
    International Journal of Control and Automation, 2015, 8 (01): : 125 - 138
  • [43] LOW VOLTAGE RELAY CONTACT RESISTANCE CHANGE INFLUENCE BY SHORT-CIRCUIT CURRENT
    Ksiazkiewicz, Andrzej
    Janiszewski, Jerzy
    EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2015, 17 (04): : 600 - 603
  • [44] A New and Efficient Algorithm for Short-circuit Calculation in Distribution Networks with Distributed Generation
    Tristiu, Ion
    Bulac, Constantin
    Costinas, Sorina
    Toma, Lucian
    Mandis, Alexandru
    Zabava, Tudor
    2015 9TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2015, : 816 - 821
  • [45] EFFECT OF NORADRENALINE AND DOPAMINE ON THE SHORT-CIRCUIT CURRENT IN THE SKIN OF THE TOAD
    SARRIES, A
    ALTENBERG, G
    AMORENA, C
    TAQUINI, AC
    MEDICINA-BUENOS AIRES, 1986, 46 (05) : 564 - 564
  • [46] MONITORING GALVANIC SHORT-CIRCUIT CURRENT
    JONES, DA
    ELECTROCHEMICAL TECHNOLOGY, 1968, 6 (7-8): : 241 - &
  • [47] SHORT-CIRCUIT CURRENT LIMITERS.
    Krause, J.C.
    EUT Report, Eindhoven University of Technology, Faculty of Electrical Engineering, 1980,
  • [48] CALCULATION OF SHORT-CIRCUIT CURRENT FLOWS
    FUCHS, R
    ENERGIETECHNIK, 1986, 36 (08): : 293 - 298
  • [49] Interval Arithmetic for Short-Circuit Computation in MV Radial Networks with Distributed Generation
    Vicente, W. C. Briceno
    Caire, R.
    Hadjsaid, N.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [50] SHORT-CIRCUIT CURRENTS CALCULATION IN DISTRIBUTION ELECTRICAL NETWORKS IN THE PRESENCE OF DISTRIBUTED GENERATION
    Zabava, Tudor-Ion
    Tristiu, Ion
    Mandis, Alexandru
    Bulac, Constantin
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2015, 77 (04): : 443 - 454