The overall performance of a novel semi-transparent photovoltaic window with passive radiative cooling coating - A comparative study

被引:4
|
作者
Wang, Wanting [1 ]
Yang, Hongxing [2 ]
Xiang, Changying [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Div Integrat Syst & Design, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Div Bldg Environm & Energy Engn, Hong Kong, Peoples R China
关键词
Building integrated photovoltaics; Passive radiative cooling; Semi-transparent PV; Color rendering index; Solar energy; ENERGY; PV; GLAZINGS; BIPV;
D O I
10.1016/j.enbuild.2024.114433
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Semi-transparent photovoltaic (STPV) glazing is a promising building integrated photovoltaic (BIPV) technology for converting traditional windows into on-site energy-producing building components. Besides electricity generation, there is also an urgent demand to enhance the thermal management of STPV glazing. Passive radioactive cooling paint is an emerging nanomaterials technology that shows great potential to reduce the painted surface temperature. Aiming to further promote the PV window's energy efficiency, this study designed and investigated a novel coated semi-transparent photovoltaic (CSTPV) glazing supplemented with highly transparent passive radiative cooling coating. In addition, the STPV/CSTPV's impacts on indoor visual environments were investigated, especially on the rarely studied aspect of interior colour rendering performance. This paper employs a combination of numerical simulation and experimental measurements to comprehensively assess these innovative glass systems in terms of electricity generation, thermal performance, daylighting efficiency, and the impact of color on the indoor environment. The results indicate that the CSTPV windows can significantly reduce the heat gain rate by about 15 % and achieve excellent electricity generation, with an annual output approximately 3 % higher than that of STPV windows. Despite the radiative cooling coating, CSTPV glazing maintains a level of daylight illumination comparable to that of STPV glazing, with glare levels remaining within acceptable limits. Furthermore, the study emphasizes the effects of CSTPV and STPV on the indoor Color Rendering Index (CRI) and Correlated Color Temperature (CCT) performance. All samples measured have CCT values within the range of neutral light, and CRI values exceeding 96, demonstrating satisfactory high-quality indoor lighting conditions. This research shows that CSTPV and STPV glass technologies not only significantly enhance the energy efficiency of buildings but also provide a scientific foundation for sustainable development in architectural design.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Performance evaluation of 7.2 kWp standalone building integrated semi-transparent photovoltaic thermal system
    Mishra, G. K.
    Tiwari, G. N.
    RENEWABLE ENERGY, 2020, 146 : 205 - 222
  • [42] Optimal design of inhomogeneous semi-transparent photovoltaic windows based on daylight performance and visual characters
    Li, Xinyi
    Peng, Jinqing
    Tan, Yutong
    He, Yingdong
    Li, Bojia
    Ju, Xiaolei
    Ji, Jie
    Zhang, Song
    Li, Nianping
    Chen, Youming
    ENERGY AND BUILDINGS, 2023, 283
  • [43] The impact of indoor air distributions on the thermal performance of a single layer semi-transparent photovoltaic facade
    Jinming Yang
    Yuanda Cheng
    Jie Jia
    Zhenyu Du
    Zhuxing Shi
    Jun Han
    Building Simulation, 2019, 12 : 69 - 77
  • [44] High-Performance Semi-Transparent Organic Photovoltaic Devices via Improving Absorbing Selectivity
    Li, Yaokai
    He, Chengliang
    Zuo, Lijian
    Zhao, Feng
    Zhan, Lingling
    Li, Xin
    Xia, Ruoxi
    Yip, Hin-Lap
    Li, Chang-Zhi
    Liu, Xu
    Chen, Hongzheng
    ADVANCED ENERGY MATERIALS, 2021, 11 (11)
  • [45] Experiments and simulations on the energy performance of semi-transparent photovoltaic roof-integrated skylight glazing
    Ding, Hao
    Yu, Guoqing
    Gu, Lin
    Luo, Daina
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2023, 16 (05) : 557 - 573
  • [46] Daylighting Performance of CdTe Semi-Transparent Photovoltaic Skylights with Different Shapes for University Gymnasium Buildings
    Wu, Yanpeng
    Li, Shaoxiong
    Gao, Xin
    Fan, Huifang
    BUILDINGS, 2024, 14 (01)
  • [47] The impact of indoor air distributions on the thermal performance of a single layer semi-transparent photovoltaic facade
    Yang, Jinming
    Cheng, Yuanda
    Jia, Jie
    Du, Zhenyu
    Shi, Zhuxing
    Han, Jun
    BUILDING SIMULATION, 2019, 12 (01) : 69 - 77
  • [48] ANALYSIS OF BUILDING ENVELOPE PERFORMANCE EFFECTS OF AN INSULATING SEMI-TRANSPARENT PHOTOVOLTAIC (STPV) GLAZING UNIT
    McLaughlin, Dirk V. P.
    Kapsis, Konstantinos
    Athienitis, Andreas K.
    Siassi, Sam
    Nichilo, Livio
    ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 6B, 2015,
  • [49] Lifetime performance of semi-transparent building-integrated photovoltaic (BIPV) glazing systems in the tropics
    Ng, Poh Khai
    Mithraratne, Nalanie
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 31 : 736 - 745
  • [50] Multi-Criteria Performance Assessment for Semi-Transparent Photovoltaic Windows in Different Climate Contexts
    Setyantho, Gigih Rahmandhani
    Park, Hansaem
    Chang, Seongju
    SUSTAINABILITY, 2021, 13 (04) : 1 - 22